Page 281
Utilities Default/Reset/Save
<Zrd> <Zrc>
Imager Status Request Commands
Other Operational Commands
<?> <K?> <K??> <K?#> <Knnn?> <Knnn??> <Knnn?#> <uy,path,filename> <dy,path,filename> <op,9> <@CAL> <BCCFG> <VAL>
FIS-6300 ESD Imager User’s Manual
Recall wenglor Default Parameters and Save for Power-On Recall Customer Default Parameters and Save for Power-On Imager Status Byte All Status Request All Descriptor Status Request All Range Status Request Single Status Request Single Descriptor Status Request Single Range Status Request Y-Modem Upload Transfer Options Y-Modem Download Transfer Options Image Library Request Autocalibrate Enter Bar Code Configuration Static Validation
13-3
Page 282
Read Rate
Read Rate Read Rate by ESP You can access Read Rate from the Utilities menu under the Read Rate tab. To see the number of decodes per second, click the Decodes/sec radio button and click the Start button. To see the percentage of decodes, click the Percent radio button and then the Start button. To end a read rate test, click the Stop button (the Start button becomes a “Stop” button during an active read rate test.)
Read Rate by Serial Command Enter Decodes / Second Test Sending <C> instructs the Imager to transmit the decodes per second and symbol data (if any). The decode rate can vary dramatically due to the angle and location of the symbol in relation to the field of view. This test is very useful in aligning and positioning the Imager during setup.
Enter Percent Test Sending <Cp> instructs the Imager to transmit the percentage of decodes and any decoded symbol data.
End Read Rate Test Sending <J> ends both the Percent test and the Decodes/Second test.
13-4
FIS-6300 ESD Imager User’s Manual
Page 283
Utilities
Counters Counter commands can be a numeric value from 00000 to 65535. After reaching the maximum numeric limit of 65535, an error message will be displayed and the counter wil automatically roll over and start counting again at 00000. To obtain the cumulative total of counts after the rollover has occurred, add 65536 per each rollover (the Imager does not keep track of the number of rollovers) to the current count. Note: All counter values will be lost if power is recycled to the Imager, or if the Imager receives a Reset or Save command.
Counters by ESP You can access Counters from ESP’s Utilities menu. Click the Request button to display the appropriate count or Clear to set the counter to zero.
FIS-6300 ESD Imager User’s Manual
13-5
Page 284
Counters by Serial Command Noread Counter Sending <N> displays the total number of noreads that have occurred since the last reset.
Noread Counter Reset Sending <O> sets the Noread Counter to 00000.
Trigger Counter Sending <T> displays the total number of triggers since the last reset.
Trigger Counter Reset Sending <U> sets the trigger counter to 00000.
Good Read / Match Counter (or Good Read Counter) Sending <V> displays the total number of good reads matching the master symbol, or, if Master Symbol is not enabled, the number of good reads since the last reset. This counter is always enabled, but will only work as a match count when Master Symbol is enabled. If Master Symbol is not enabled, this counter records the number of good reads. This count can be requested at any time.
Good Read / Match Counter Reset Sending <W> sets the Match Counter to 00000.
Mismatch Counter Sending <X> displays the number of decoded symbols since the last reset that do not match the master symbol.
Mismatch Counter Reset Sending <Y> sets the Mismatch Counter to zero.
13-6
FIS-6300 ESD Imager User’s Manual
Page 285
Utilities
Device Control Device Control by ESP
Device Control by Serial Command Output 1 Pulse Sending <L1> activates the link between Output 1 (+) and Output 1 (-) of the host connector (regardless of Master Symbol or Output 1 status).
Output 2 Pulse Sending <L2> activates the link between Output 2 (+) and Output 2 (-) of the host connector (regardless of Master Symbol or Output 2 status).
Output 3 Pulse Sending <L3> activates the link between Output 3 (+) and Output 3 (-) of the host connector (regardless of Master Symbol or Output 3 status).
Disable Imager Sending <I> will turn the Imager OFF, end the current read cycle, and will not allow the Imager to enter another read cycle until turned ON. This feature is useful during extended periods of time when no symbols are being decoded, or the Imager is being configured. Disabling the Imager will not affect any commands that have already been downloaded.
Enable Imager Sending <H> will turn the Imager ON and allow it to enter read cycles.
Enable PDF Information Sending <a1> will cause PDF417 data to be prefaced with information consisting of error correction level (ECC level n), number of rows (n rows), number of columns (n columns), number of informative code words (n info code words), and the number of data characters (n data bits). Send <a1> again to disable PDF Information. FIS-6300 ESD Imager User’s Manual
13-7
Page 286
Master Database
Master Database Important: The Master Database is used for all Matchcode modes except Sequential and Wild Card, both of which use Master Database Index # 1.
Master Database Overview Usage: Definition:
Used where more than one master symbol is required, as in a Multisymbol setup, for matching and other Matchcode operations. Allows the user to define up to 10 master symbols as the master symbol database, which can be entered by keyboard, scanned in, displayed, or deleted by serial or ESP commands.
1. Click the Master Database tab. 2. Enable Matchcode Type. 3. Set the Master Symbol Database Size. 4. Select the database index in which you want to enter the master symbol. 5. Do one of the following to enter master symbol data: a. Double-click the index row to type data directly into the index. b. Click the Read Symbol into Selected Index to enter the next decoded symbol. Set Master Symbol Database Size here.
Double-click row to enter data into popup dialog box.
13-8
Loads the Imager’s saved master symbols into ESP.
Loads the next symbol decoded into the selected index.
Saves the displayed database to the Imager.
FIS-6300 ESD Imager User’s Manual
Page 287
Utilities
Master Symbol Database Size Definition: Serial Cmd: Default: Options:
Number of Master Symbols allows you to select 1 to 10 master symbols for the master symbol database. <K231,master symbol database size> Note: You must follow this command with a save command <A> or <Z>. 1 1 to 10
Use up and down arrows to set Master Symbol Database Size.
Caution: Since the total number of characters available for the master symbol database is 3000, changes to the Master Symbol Database Size will re-allocate the number of characters available for each master symbol and could cause existing master symbols to be deleted (except master symbol #1, unless it also exceeds the size limitation). The table below specifies the maximum number of characters available to each symbol according the number of master symbols defined, from 1 to 10. Master Symbol Number #1 #2 #3 #4 #5
Maximum Characters 3000 1500 1000 750 600
FIS-6300 ESD Imager User’s Manual
Master Symbol Number #6 #7 #8 #9 # 10
Maximum Characters 500 428 375 333 300
13-9
Page 288
Master Database
Enter Master Symbol Data Usage:
Allows you to enter master symbol data for any enabled master symbol index number (1 to 10), provided the total number of characters does not exceed the maximum allowed. Serial Cmd: <K231,master symbol number,master symbol data> Options: Enter data for 1 to 10 symbols (any combination of ASCII text up to the maximum allowed. For example, to enter data for master symbol 9, after making certain that master symbol database size is enabled for 9 or more symbols, send <K231,9,data>. Important: The ASCII characters <, >, and , can only be entered as hex pairs. See ASCII Character Entry Modifier on page 3-23 for a detailed explanation of how to enter ASCII characters as hex values. ESP:
Caution: If no data is entered, the existing data will be deleted. 1. Open the Utilities menu. 2. Set the number of master symbols you want to create in Master Symbol Database Size. 3. Double-click on each symbol number you want to set up and copy, or type your data in the popup dialog and click OK.
4. When all your data has been entered, click the Send Database to the Reader button.
13-10
FIS-6300 ESD Imager User’s Manual
Page 289
Utilities
Request Master Symbol Data Definition:
Serial Cmd:
Returns master symbol data for any enabled master symbols from 1 to 10. For example, to request master symbol # 5, enter <K231?,5>. The Imager transmits master symbol # 5 data in brackets in the following format: <5/>. If no master symbol data is available, the output will be: <5/>. <K231?,master symbol number> Caution: Be sure to add the ? or you will delete the master symbol. Note: This command returns the number of master symbols if no number is included.
ESP:
1. Click the Utilities button and the Master Database tab. 2. Click the Receive Reader’s Database button.
Request All Master Symbol Data Definition: Serial Cmd:
This command will return master symbol data for all symbols enabled (up to 10). <K231?>
FIS-6300 ESD Imager User’s Manual
13-11
Page 290
Read Next Symbol as Master Symbol Definition: Serial Cmd:
ESP:
After you’ve set the size in the database, you can order the Imager to read the next symbol as the master symbol for any given master symbol number. <Gmaster symbol number> To store the next symbol decoded as master symbol #1, send: <G> or <G1>. To store the next symbol decoded as the master symbol for any other master symbol database number, send: <Gmaster symbol number [1-10]>. For example, <G5> will cause the next symbol read to be entered as master symbol # 5. In the Master Database tab under the Output Format menu, 1. Select the master symbol index number in which you want to store the symbol data. 2. Click the Read Symbol into Selected Index button.
Caution: If you’ve selected an index which already has existing data, that data will be copied over by new decoded data when you use this command.
Request New Master Status Usage: Definition: Serial Cmd:
Informs the user when a new master symbol is pending and which position it is in. Returns the position in the master symbol database that will be loaded on the next read. <NEWM> The Imager returns: <NEWM/next master to load> Once a symbol has been read and loaded, the status will be cleared and the response will be <NEWM/0>.
(See also New Master Pin in Chapter 9.)
13-12
FIS-6300 ESD Imager User’s Manual