Page 271
Configuration Database
Request Selected Index Settings Definition: Serial Cmd:
Returns configuration settings for the selected database index. <K255?,index>
Example: <K255?,5> This command phrase returns the configuration settings for database index 5.
FIS-6300 ESD Imager User’s Manual
11-17
Page 272
Request All Configuration Database Settings
Request All Configuration Database Settings Definition: Serial Cmd:
Returns configuration settings for all indexes in the configuration database. <K255?>
Example: <K255?> This command phrase returns the configuration settings for all 10 database indexes.
11-18
FIS-6300 ESD Imager User’s Manual
Page 273
12 Terminal Contents Terminal Window........................................................................................................................ 12-2 Find Function.............................................................................................................................. 12-3 Macros........................................................................................................................................ 12-4 Terminal Window Functions ....................................................................................................... 12-5
This section describes the Terminal window and macro functions in ESP.
FIS-6300 ESD Imager User’s Manual
12-1
Page 274
Terminal Window
Terminal Window To use ESP’s Terminal, click on the Terminal button:
You will see this window: Clear screen
Macros listed on this bar
Copy, paste, save
Type text here to find matching text in the Terminal window.
Terminal screen
Click on Macros arrow to Add Macro, Remove Macro, or Edit Macro.
Type serial commands here.
Click on desired Macro to run.
The Terminal screen allows you to send serial commands to the Imager by using Macros, by copying and pasting, or by typing commands in the “Send” text field. The Terminal screen also displays symbol data or information from the Imager. You can also right click on the Terminal screen to bring up a menu of further options. 12-2
FIS-6300 ESD Imager User’s Manual
Page 275
Terminal
Find Function The Find box allows you to enter text strings to be searched for in the Terminal window. For example, a series of symbols have been read into the Terminal view and you want to determine if a particular code starting with “ABC” has been read. 1. Type ABC into the Find box.
2. Press Enter. The first instance of ABC will be highlighted in the Terminal window. 3. Press the F3 key to search again for the next instance of ABC. 4. Press Shift-F3 to search for the previous instance of ABC.
FIS-6300 ESD Imager User’s Manual
12-3
Page 276
Macros
Macros Macros can be stored in a macro selection bar, edited in a separate window, and executed by clicking on the macro name.
Click on Next Row to see the next row of macros
Click on the first arrow here to see Add Macro or Default Macros. When you default macros, the entire macros set is restored to their original macro commands.
Click on subsequent arrows to edit macros.
When you click on the macro name, the macro is executed in the Terminal window. If this is a command, it is sent to the Imager at the same time that it is displayed.
Editing a Macro When you click the arrow next to any macro and select Edit, the following appears:
You can edit an existing macro or type in the Macro Name text field and define it in the Macro Value text field. Click OK.
12-4
FIS-6300 ESD Imager User’s Manual
Page 277
Terminal
Terminal Window Functions Right click on the Terminal window to display the following pulldown menu: • Copy selected text to clipboard. • Paste from Terminal or computer text. • Clear all text in Terminal window. • Select All text in the Terminal window. • Save... brings up a save as dialog box. • Change Font... of data text, brings up a text dialog. • Change Echo Font... to change typed in text or commands. • Change Background Color of Terminal window. • Default Settings changes all the above back to default settings.
Terminal Dropdown Menu The dropdown Terminal menu has Capture Text and Save Current Text functions, as well as the functions defined above. • Capture lets you append data in real time to a text file of your choice. While in operation, the text file cannot be opened. You can select Pause to interrupt the capture flow or Stop to end the flow and open the file. • Save Current Text... saves all text in the Terminal window to a text file of your choice.
FIS-6300 ESD Imager User’s Manual
12-5
Page 278
Terminal Window Functions
12-6
FIS-6300 ESD Imager User’s Manual
Page 279
13 Utilities Contents Serial Utility Commands ............................................................................................................. 13-2 Read Rate .................................................................................................................................. 13-4 Counters ..................................................................................................................................... 13-5 Device Control ............................................................................................................................ 13-7 Master Database ........................................................................................................................ 13-8 Firmware................................................................................................................................... 13-14 Bar Code Configuration ............................................................................................................ 13-17 Default / Reset / Save............................................................................................................... 13-18 Imager Status Requests ........................................................................................................... 13-20 Other Operational Serial Commands ....................................................................................... 13-22
Utility commands are generally commands that are performed during Imager operations to check or determine read rates, or to perform miscellaneous operations on Imager hardware. Serial utility commands are not prefaced with a “K” and a numeric code, nor do they require an initialization command (<A> and <Z>). They can be entered from within any terminal program or from ESP’s Terminal or Utilities windows.
FIS-6300 ESD Imager User’s Manual
13-1
Page 280
Serial Utility Commands
Serial Utility Commands Type Read Rate
Counter Request and Clear
Master Database
Part Number / Checksum
Device Control
Default/Reset/Save
Command <C> <Cp> <J> <N> <O> <T> <U> <V> <W> <X> <Y> <G> <Gn> <NEWM> <#> <#a> <#b> <#p> <!> <!a> <!b> <!p> <L1> <L2> <L3> <11> <10> <I> <H> <a1> <A> <Ard> <Arp> <Arc> <Z> <Zc>
13-2
Name Enter Decode Rate Test Enter Percent Rate Test Exit Decode Rate and Percent Rate Test Noread Counter Noread Counter Reset Trigger Counter Trigger Counter Reset Good Read/Match Counter Good Read/Match Counter Reset Mismatch Counter Mismatch Counter Reset Store Next Symbol Read to Database Index 1 Store Next Symbol Read to Database Index n New Master Load Status Display All Firmware Part Numbers Display Application Code Part Number Display Boot Code Part Number Display Profile Module Part Numbers Display All Available Firmware Checksums Display Application Code Code Checksum Display Boot Code Checksum Display Profile Module Checksum Programmable Output 1 Programmable Output 2 Programmable Output 3 Targeting System On Targeting System Off Disable Imager Enable Imager Include PDF Information in Preamble (PDF417) Reset (does not save for power-on) Reset and Recall wenglor Defaults Reset and Recall Power-On Parameters Reset and Recall Customer Default Parameters Save Current Settings for Power-On Save Current Settings as Customer Default Parameters for Power-On FIS-6300 ESD Imager User’s Manual