The text of a manual · part 27 of 37
FIS-6300 ESD Imager User's Manual, pages 261 to 270
Pages 261 to 270 of 364
The original document is the PDF (5.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Wenglor FIS-6300
Page 261
Configuration Database
Processing Mode Serial Cmd: <K255,index,shutter speed,gain,focal distance,sub-sampling,row pointer,column pointer,row depth,column width,threshold mode,fixed threshold value,processing mode,background color,narrow margins,symbology type> Default: Standard Options: 0 = Standard 1 = Fast Linear Mode
Background Color Serial Cmd: <K255,index,shutter speed,gain,focal distance,sub-sampling,row pointer,column pointer,row depth,column width,threshold mode,fixed threshold value,processing mode,background color,narrow margins,symbology type> Default: White Options: 0 = White 1 = Black
Narrow Margins Serial Cmd: <K255,index,shutter speed,gain,focal distance,sub-sampling,row pointer,column pointer,row depth,column width,threshold mode,fixed threshold value,processing mode,background color,narrow margins,symbology type> Default: Disabled Options: 0 = Disabled 1 = Enabled
FIS-6300 ESD Imager User’s Manual
11-7
Page 262
Configuration Database Status
Symbology Type Definition:
This field allows the user to configure the database to enable specific symbologies for selected database indexes. Symbology-specific parameters must be configured with the appropriate symbology command. For example, if fixed length Code 128 is required, it must first be set up with the Code 128 command: <K474>. To select a particular symbology, just add the number value associated with that symbology type. Examples: If Data Matrix and Code 39 are required, the paramater would be: 2 + 16 = 18.
If I 2/5, BC412, and RSS Limited are required, the parameter would be: 128 + 2048 + 16384 = 18560. Serial Cmd: <K255,index,shutter speed,gain,sub-sampling,row pointer,column pointer,row depth,column width,threshold mode,fixed threshold value,processing mode,background color,narrow margins,symbology type> Default: Disabled
Disabled When Symbology Type is disabled, the database uses the current Symbology Type setup to determine active symbologies.
Any Symbology Type (Add 1) All symbologies except PharmaCode are enabled while this database index is being used.
Data Matrix (Add 2) If enabled, Data Matrix will be active for this database index. Important: The ECC level must be configured using the Data Matrix command <K479>. If no ECC level has been configured, the Imager will not decode Data Matrix symbols.
QR Code (Add 4) If enabled, QR Code will be active for this database index.
Code 128 (Add 8) If enabled, Code 128 will be active for this database index.
Code 39 (Add 16) If enabled, Code 39 will be active for this database index.
Codabar (Add 32) If enabled, Codabar will be active for this database index. 11-8
FIS-6300 ESD Imager User’s Manual
Page 263
Configuration Database
Code 93 (Add 64) If enabled, Code 93 will be active for this database index.
Interleaved 2 of 5 (Add 128) If enabled, Interleaved 2 of 5 will be active for this database index.
UPC/EAN (Add 256) If enabled, UPC/EAN will be active for this database index.
PDF417 (Add 512) If enabled, PDF417 will be active for this database index.
MicroPDF417 (Add 1024) If enabled, MicroPDF417 will be active for this database index.
BC412 (Add 2048) If enabled, BC412 will be active for this database index.
PharmaCode (Add 4096) If enabled, PharmaCode will be active for this database index.
RSS-14 (Add 8192) If enabled, RSS-14 will be active for this database index. Important: If the stacked and non-stacked operation is required, the RSS-14 command must be configured as follows: <K482,2>. If the RSS-14 status parameter in the <K482> command is set to either DISABLED or ENABLED, the Imager will only read non-stacked RSS-14 symbols.
RSS Limited (Add 16384) If enabled, RSS Limited will be active for this database index.
RSS Extended (Add 32768) If enabled, RSS Extended will be active for this database index. Important: If the stacked and non-stacked operation is required, the RSS Extended command must be configured as follows: <K484,2>. If the RSS Extended status parameter in the <K484> command is set to either DISABLED or ENABLED, the Imager will only read non-stacked RSS Extended symbols.
FIS-6300 ESD Imager User’s Manual
11-9
Page 264
Database Mode
Database Mode Switch Mode Definition:
Selects the event that causes the Imager to load the next database entry to current, active settings. When Frame Count/Time expires and Image Process Looping is enabled, the next database entry with modifications to camera settings will be used. Note: The image capture event always occurs when the first database entry is used. Note: The Switch Mode setting has no effect on Rapid Capture Mode, which always operates in Number of Image Frames mode with a frame count of 1. Serial Cmd: <K256,switch mode,frame count/time,image process looping,image dimensions> Default: 1 Options: 0 = Time 1 = Number of Image Frames
Time When Switch Mode is set to Time, the Imager will load the next database entry to current, active settings after a predefined time interval. The timer will start upon use of a database entry. If the timer expires during an image capture event, the timer will not start again until that database entry has been incremented and the new database entry has been loaded to current, active settings.
Number of Image Frames When Switch Mode is set to Number of Image Frames, the database entry is incremented after the predetermined number of image capture events has occurred.
Frame Count/Time Definition:
Indicates the Number of Image Frames that must be captured or the amount of Time that must transpire before the Imager will load the next database index entry. Serial Cmd: <K256,switch mode,frame count/time,image process looping,image dimensions> Default: 1 (frames/mS) Options: 1 to 65535
11-10
FIS-6300 ESD Imager User’s Manual
Page 265
Configuration Database
Image Process Looping Usage:
Useful in applications where it is necessary to process a single captured image multiple times using different IP and decode parameters. Serial Cmd: <K256,switch mode,frame count/time,image process looping,image dimensions> Default: Disabled Options: 0 = Disabled 1 = Enabled
Disabled When Image Process Looping is set to Disabled, an image is captured for every database configuration, whether or not any camera settings have been modified.
Enabled When Image Process Looping is set to Enabled, the last captured image frame is reprocessed with the new IP and decode parameters. If camera settings have not been changed from the last capture event, and when a database configuration is loaded to current, active settings, no new image is captured. Note: An exception to this is the first database index: a new image is always captured when the first database index is used. When a camera setting has been modified from one database setting to the next, a new image is captured. For example, if all database entries contained the same camera setting values but had different IP and decode parameters, an image frame would only be captured when the first database configuration was used.
FIS-6300 ESD Imager User’s Manual
11-11
Page 266
Database Mode
Image Dimensions Definition: Serial Cmd: Default: Options:
Determines how the image dimension parameters will be implemented. <K256,switch mode,frame count/time,image process looping,image dimensions> 0 0 = Window of Interest 1 = Region of Interest
Window of Interest (WOI) by ESP When Image Dimensions is set to Window of Interest, the database image dimension parameters are camera settings, and they determine the size of the image to be captured.
Camera settings (Capture Index, Shutter Speed, Gain, Focal Distance, Sub-Sampling) located in the left half of the highlighted area. Image capture dimensions (Row Pointer, Column Pointer, Row Depth, Column Width) located in the right half of the highlighted area.
11-12
FIS-6300 ESD Imager User’s Manual
Page 267
Configuration Database
Region of Interest (ROI) When Image Dimensions is set to Region of Interest, the database image dimension parameters are IP and decode settings, and they determine the region or area of the captured image to be processed. ROI coordinate data is based on the full image size. The WOI of the captured image will be configured to cover all the ROI settings in the current, active database entry. In the following example, there are three active database settings, each with a different ROI configuration. Their coordinates are based at point 0,0 of the full scale image (1280 x 1024). In this example, DB1 and DB3 determine the size of the captured image WOI, while DB2 has no impact. The image WOI is not configurable. It is automatically set up by the database according to the ROI settings. row pointer column pointer
DB 1 IP ROI row size
DB 2 IP ROI column size
DB 3 Camera WOI
IP ROI
Full Image Size (1280 x 1024) Note: Since the ROI parameters are not a camera setting, a change in ROI parameters from one index to another does not indicate an image capture event. This feature is intended to be used in conjunction with Image Process Looping, to allow different regions of a captured image to be processed using different IP and decode settings. Also, if this feature is used in conjunction with Output Filtering, multiple decoded symbols in a captured image frame can be output according to their location in the field of view. FIS-6300 ESD Imager User’s Manual
11-13
Page 268
Database Mode
Region of Interest (ROI) by ESP When Image Dimensions is set to Region of Interest, the database image dimension parameters are IP and decode settings, and they determine the region or area of the captured image to be processed.
Threshold Mode, Fixed Threshold Value, Processing Mode, Narrow Margins, Background, and Code Type are all Processing Settings values.
11-14
FIS-6300 ESD Imager User’s Manual
Page 269
Configuration Database
Save Current Settings to Configuration Database Definition: Serial Cmd:
Allows current, active configuration settings to be saved to a selected database index. <K255+,index>
Example: <K255+,5> This command phrase saves the Imager’s current, active configuration settings to database index 5.
By ESP
Click the Load Current to Index button to save the Imager’s current configuration parameters to the selected database index.
FIS-6300 ESD Imager User’s Manual
11-15
Page 270
Load Current Settings from Configuration Database
Load Current Settings from Configuration Database Definition: Serial Cmd:
Allows the configuration settings contained in a selected database index to be loaded to current, active configuration settings. <K255-,index>
Example: <K255-,5> This command phrase loads the configuration settings contained in database index 5 to current, active configuration settings.
By ESP
Click the Load Index to Current button to load configuration settings from the selected index to current, active settings.
11-16
FIS-6300 ESD Imager User’s Manual