For the Wenglor FIS-6300

Page 251

Camera and IP Setup

Hollow Mode Usage: Definition:

Serial Cmd: Default: Options:

Used to determine which kind of data matrix elements will be processed. When set to Regular Elements, the Imager will decode data matrix symbols with solid elements but will not decode data matrix symbols with hollow elements. When set to Hollow Elements, the Imager will decode data matrix symbols with outlined, hollow elements but will not decode data matrix symbols with solid elements. <K517,hollow mode status> Regular Elements 0 = Regular Elements 1 = Hollow Elements

The image below is an example of a data matrix symbol with hollow elements.

FIS-6300 ESD Imager User’s Manual

10-27

Page 252

Mirrored Image

Mirrored Image Usage: Definition: Serial Cmd: Default: Options:

Enable this setting when the Imager is viewing a mirrored image (as when it is being used with a right-angle mirror attachment). When enabled, outputs a mirrored image of the symbol. <K514,mirrored image> Both 0 = Regular Image 1 = Mirrored Image 2 = Both

Regular Image When Regular Image is enabled, images will be processed as they appear upon capture.

Mirrored Image When Mirrored Image is enabled, images will be processed as a reverse of the captured image.

Both When Both is enabled, regular and mirrored images will be processed.

10-28

FIS-6300 ESD Imager User’s Manual

Page 253

Camera and IP Setup

Illumination Brightness Definition:

Usage: Default: Options:

This feature allows the user to adjust the brightness of the illumination LEDs. Since the Imager has control over the brightness of the illumination, it can provide consistent brightness output between Imagers through a factory calibration operation. Each of the brightness settings are calibrated to provide the same level of intensity for each Imager. <K536,brightness> High 0 = Off 1 = Low 2 = Medium 3 = High

FIS-6300 ESD Imager User’s Manual

10-29

Page 254

Illumination Brightness

10-30

FIS-6300 ESD Imager User’s Manual

Page 255

11 Configuration Database Contents Configuration Database Serial Commands ................................................................................ 11-2 Number of Active Indexes .......................................................................................................... 11-3 Configuration Database Status................................................................................................... 11-4 Database Mode ........................................................................................................................ 11-10 Save Current Settings to Configuration Database.................................................................... 11-15 Load Current Settings from Configuration Database................................................................ 11-16 Request Selected Index Settings ............................................................................................. 11-17 Request All Configuration Database Settings .......................................................................... 11-18

This section concerns the various capture settings and processing settings that can be used to fine-tune the FIS-6300 ESD Imager’s performance in your application.

FIS-6300 ESD Imager User’s Manual

11-1

Page 256

Configuration Database Serial Commands

Configuration Database Serial Commands Number of Active Indexes Configuration Database Status

Save Current Settings to Database Load Current Settings from Database Request Selected Index Settings Request All Database Settings Database Mode

11-2

<K252,number of active database settings> <K255,index,shutter speed,gain,focal distance,digital zoom,row pointer,column pointer,row depth, column width,threshold mode,fixed threshold value,processing mode,background color,narrow margins,symbology type> <K255+,index> <K255-,index> <K255?,index> <K255?> <K256,switch mode,frame count/time,image process looping,image dimensions>

FIS-6300 ESD Imager User’s Manual

Page 257

Configuration Database

Number of Active Indexes Usage:

Definition:

Serial Cmd: Default: Options:

Useful for applications that require several different complex Imager configurations to be applied sequentially. Multiple database indexes allow you to concatenate configuration profiles, and to perform more complex operations than would be possible with only one set of configuration parameters. This feature allows you to set the number of database records (groups of settings) that will be used automatically during the read cycle. If Number of Active Indexes is set to 0, only the current Imager settings will be used, not database entry settings. <K252,number of active indexes> 0 (disabled) 0 to 10

By ESP

Click the arrow on the Active Indexes dropdown menu and select how many database indexes will be used during the read cycle. (0 to 10).

FIS-6300 ESD Imager User’s Manual

11-3

Page 258

Configuration Database Status

Configuration Database Status Index Usage:

Useful for applications that require several different complex Imager configurations to be applied sequentially. Multiple database indexes allow you to concatenate configuration profiles, and to perform more complex operations than would be possible with only one set of configuration parameters. Definition: Determines the specific database index that will be used. Serial Cmd: <K255,index,shutter speed,gain,focal distance,sub-sampling,row pointer,column pointer,row depth,column width,threshold mode,fixed threshold value,processing mode,background color,narrow margins,symbology type> Options: 0 to 10

Shutter Speed Serial Cmd: <K255,index,shutter speed,gain,focal distance,sub-sampling,row pointer,column pointer,row depth,column width,threshold mode,fixed threshold value,processing mode,background color,narrow margins,symbology type> Default: 250 Options: 15 to 10,000

Gain Serial Cmd: <K255,index,shutter speed,gain,focal distance,sub-sampling,row pointer,column pointer,row depth,column width,threshold mode,fixed threshold value,processing mode,background color,narrow margins,symbology type> Default: 20 Options: 0 to 48

Focal Distance Serial Cmd: <K255,index,shutter speed,gain,focal distance,sub-sampling,row pointer,column pointer,row depth,column width,threshold mode,fixed threshold value,processing mode,background color,narrow margins,symbology type> Default: 400 (4”) Options: 200 to 600

11-4

FIS-6300 ESD Imager User’s Manual

Page 259

Configuration Database

Pixel Sub-Sampling Serial Cmd: <K255,index,shutter speed,gain,focal distance,sub-sampling,row pointer,column pointer,row depth,column width,threshold mode,fixed threshold value,processing mode,background color,narrow margins,symbology type> Default: Disabled Options: 0 = Disabled 1 = 4:1 2 = 16:1 Important: Sub-sampling has no effect when the Image Dimension mode is configured as Region of Interest in the Database Mode command. This is because the Window of Interest camera settings are determined by the software based on the Region of Interest setup. There is no benefit to sub-sampling to increase processing speed when ROI is configured, because the frame size would need to be increased to make sub-sampling possible.

Row Pointer Definition:

The image dimension settings can be applied as a Window of Interest or a Region of Interest, depending on the image dimension mode selected in the Database Mode command. Serial Cmd: <K255,index,shutter speed,gain,focal distance,sub-sampling,row pointer,column pointer,row depth,column width,threshold mode,fixed threshold value,processing mode,background color,narrow margins,symbology type> Default: 0 Options: 0 to (1024-row depth)

Column Pointer Definition:

The image dimension settings can be applied as a Window of Interest or a Region of Interest, depending on the image dimension mode selected in the Database Mode command. Serial Cmd: <K255,index,shutter speed,gain,focal distance,sub-sampling,row pointer,column pointer,row depth,column width,threshold mode,fixed threshold value,processing mode,background color,narrow margins,symbology type> Default 0 Options: 0 to (1280-column width)

FIS-6300 ESD Imager User’s Manual

11-5

Page 260

Configuration Database Status

Row Depth Definition:

The image dimension settings can be applied as a Window of Interest or a Region of Interest, depending on the image dimension mode selected in the Database Mode command. Serial Cmd: <K255,index,shutter speed,gain,focal distance,sub-sampling,row pointer,column pointer,row depth,column width,threshold mode,fixed threshold value,processing mode,background color,narrow margins,symbology type> Default: 1024 Options: 3 to (1024-row pointer)

Column Width Definition:

The image dimension settings can be applied as a Window of Interest or a Region of Interest, depending on the image dimension mode selected in the Database Mode command. Serial Cmd: <K255,index,shutter speed,gain,focal distance,sub-sampling,row pointer,column pointer,row depth,column width,threshold mode,fixed threshold value,processing mode,background color,narrow margins,symbology type> Default 1280 Options: 8 to (1280-column pointer)

Threshold Mode Serial Cmd: <K255,index,shutter speed,gain,focal distance,sub-sampling,row pointer,column pointer,row depth,column width,threshold mode,fixed threshold value,processing mode,background color,narrow margins,symbology type> Default: Adaptive Options: 0 = Adaptive 1 = Fixed

Fixed Threshold Value Serial Cmd: <K255,index,shutter speed,gain,focal distance,sub-sampling,row pointer,column pointer,row depth,column width,threshold mode,fixed threshold value,processing mode,background color,narrow margins,symbology type> Default: 128 Options: 0 to 255

11-6

FIS-6300 ESD Imager User’s Manual