Page 241
Camera and IP Setup
High Density Optics (1.0 mm Aperture), 4” Focal Distance Shutter Speed Usage:
Definition:
Serial Cmd: Default: Options:
Faster shutter speeds reduce blurring in faster applications. Slower shutter speeds are useful in slower applications and lower contrast applications. This value sets the exposure or integration time for the image sensor pixels. The shutter speed setting in relation to the speed of the object is critical. If a slow shutter speed is selected to capture fast-moving objects, blurring or smearing of the image will occur. As shutter speed is increased, more light and gain become necessary, because the pixels’ exposure time has decreased. <K541,shutter speed,gain> 30 (1/30 second) 15 to 10,000
Gain Usage: Definition:
Serial Cmd: Default: Options:
Can be used to adjust pixel grayscale values for readability. Sets the gain value for the image sensor. This setting can be configured through autocalibration, which is the recommended method. A higher gain value will increase the brightness of the image, but the visual noise reduction performance of the system is reduced. Before configuring gain settings, the desired shutter speed should already be set and the gain should be configured to optimize the shutter speed setting. <K541,shutter speed,gain> 20 0 to 48
FIS-6300 ESD Imager User’s Manual
10-17
Page 242
Ultra High Density Optics (2.5 mm Aperture), 3” Focal Distance Shutter Speed Usage:
Definition:
Serial Cmd: Default: Options:
Faster shutter speeds reduce blurring in faster applications. Slower shutter speeds are useful in slower applications and lower contrast applications. This value sets the exposure or integration time for the image sensor pixels. The shutter speed setting in relation to the speed of the object is critical. If a slow shutter speed is selected to capture fast-moving objects, blurring or smearing of the image will occur. As shutter speed is increased, more light and gain become necessary, because the pixels’ exposure time has decreased. <K541,shutter speed,gain> 300 (1/300 second) 15 to 10,000
Gain Usage: Definition:
Serial Cmd: Default: Options:
10-18
Can be used to adjust pixel grayscale values for readability. Sets the gain value for the image sensor. This setting can be configured through autocalibration, which is the recommended method. A higher gain value will increase the brightness of the image, but the visual noise reduction performance of the system is reduced. Before configuring gain settings, the desired shutter speed should already be set and the gain should be configured to optimize the shutter speed setting. <K541,shutter speed,gain> 20 0 to 48
FIS-6300 ESD Imager User’s Manual
Page 243
Camera and IP Setup
Focal Distance Definition:
Serial Cmd: Default:
Options:
This setting provides a means for configuring the focal distance of the Imager. The input value is in terms of inches and is divided by 100 internally. For example, 400 sets the Imager to a focal distance of 4 inches. It is important to note that the Imager may not have an exact match for the focal position requested. The Imager has a range of steps that are calibrated and mapped to focal positions. This input value is matched to the closest focal position step that the system supports. It is also important to keep in mind that the resolution of the system is not linear. As the Imager’s focal distance setting increases, the resolution decreases. This effect is offset somewhat by the fact that the depth of field increases at greater focal distances. <K525,focal distance> Standard Density = 400 (4”) High Density = 400 (4”) Ultra High Density = 300 (3”) 200 (2”) to 600 (6”)
Note: In the factory, the Imager calibrates its focus curve and matches the focus motor steps to various focal positions. Therefore, each Imager has a slightly different focus map of stepper motor positions vs. focal positions. This allows the user to enter a focal distance that causes the Imager to select the closest stepper motor position required to obtain the user-defined setting. In this way, there is consistency between Imagers for any given focal distance input. Note: To view a list of focal distances supported by your Imager, use the <K526> command.
FIS-6300 ESD Imager User’s Manual
10-19
Page 244
Focal Distance Table (Read Only)
Focal Distance Table (Read Only) Number of Focal Distances Definition: Serial Cmd: Options:
Specifies the number of focal distances supported by the Imager. <K526,number of focal distances,focal distance> 1 to 255
Focal Distance Definition:
Serial Cmd: Options:
10-20
Each (x) output represents a focal distance that is supported by the Imager. The values are specified in 1/100ths of an inch, but the focal distance increments and decrements are not that fine. The focal distance is defined from a curve equation whose constants are calibrated during factory setup. The output value is in terms of inches, and it is multiplied by 100 to remove the decimal place. For example, an output of 375 would signify a focal distance of 3.75”. <K526,number of focal distances,focal distance> 200 (2”) to 600 (6”)
FIS-6300 ESD Imager User’s Manual
Page 245
Camera and IP Setup
Increment Focus Position Definition:
Serial Cmd: Options:
Increments the Imager’s focus setting to the next focal distance supported by the Imager. Note: Use the Focus Distance Table command <526> to find the focal distance settings supported by your Imager. <525+> 200 (2”) to 600 (6”)
The following example assumes a focus position setting of 400 (4”), with access to the focus distance values shown in the Imager response. Send: <K526?> Response: <K526,30,202,212,225,241,264,410,447,466,481,492,502,511,519,526,533, 539,545,550,556,561,565,570,574,578,582,586,590,594,597,601> The current focus position would be 410 (4.1”). Send: <525+> Send: <525?> Response: <K525,447>
Decrement Focus Position Definition:
Serial Cmd: Options:
Decrements the Imager’s focus setting to the next focal distance supported by the Imager. Note: Use the Focus Distance Table command <526> to find the focal distance settings supported by your Imager. <525-> 200 (2”) to 600 (6”)
The following example assumes a focus position setting of 400 (4”), with access to the focus distance values shown in the Imager response. Send: <K526?> Response: <K526,30,202,212,225,241,264,410,447,466,481,492,502,511,519,526,533, 539,545,550,556,561,565,570,574,578,582,586,590,594,597,601> The current focus position would be 410 (4.1”). Send: <525-> Send: <525?> Response: <K525,264>
FIS-6300 ESD Imager User’s Manual
10-21
Page 246
IP Threshold
IP Threshold Threshold Mode Usage:
Fixed Mode works best when decode time must be as short as possible and the reflectance and illumination of the symbol area is uniform and unchanging. Cycle Fixed Mode is useful in applications where decode time can be slightly longer, and reflectance and illumination of the symbol area is uniform and unchanging. Otherwise, Adaptive Mode is the preferred mode. This value switches the image processing threshold mode between the Adaptive, Fixed, and Cycle Fixed modes. An adaptive routine sets the light/dark threshold using data acquired from the current read. A fixed routine applies the same gray scale threshold value to each and every symbol. A cycle fixed routine loops through a pre-defined range of values (Cycle Min to Cycle Max) by pre-defined increments (Cycle Step). <K512,threshold mode,threshold value,cycle min,cycle max,cycle step> Adaptive 0 = Adaptive 1 = Fixed 2 = Cycle Fixed
Definition:
Serial Cmd: Default: Options:
Threshold Value Usage:
A higher value will increase the threshold for distinguishing between light and dark elements. Determines how the Imager will distinguish light pixels from dark pixels. This value is used for Fixed Mode only. When Adaptive Mode is set, this value is ignored. <K512,threshold mode,threshold value,cycle min,cycle max,cycle step> 128 0 to 255
Definition:
Serial Cmd: Default: Options:
Cycle Min Definition: Serial Cmd: Default: Options:
10-22
Starting value of the cycle mode. <K512,threshold mode,threshold value,cycle min,cycle max,cycle step> 0 0 to 255 Important: Cycle Min must be a smaller numerical value than Cycle Max.
FIS-6300 ESD Imager User’s Manual
Page 247
Camera and IP Setup
Cycle Max Definition: Serial Cmd: Default: Options:
Ending value of the cycle mode. <K512,threshold mode,threshold value,cycle min,cycle max,cycle step> 255 0 to 255 Important: Cycle Max must be a greater numerical value than Cycle Min.
Cycle Step Definition: Serial Cmd: Default: Options:
The numerical value of a single cycle mode increment. <K512,threshold mode,threshold value,cycle min,cycle max,cycle step> 10 0 to 255
FIS-6300 ESD Imager User’s Manual
10-23
Page 248
Number of Symbols in Field of View
Number of Symbols in Field of View Definition: Serial Cmd: Default: Options:
This command allows the user to determine how FLM will behave in relation to the candidate symbols in the field of view. <K518,number of symbols in field of view> 0 0 = Any number of symbols 1 = One symbol 2 = More than one symbol
Note: When the number of symbols in the field of view is set to 1, codeword stitching from all scaled image processes is allowed for PDF417 and MicroPDF417. Note: This variable is used in Fast Linear Mode. FLM usually considers the whole image as one candidate, but when Number of Symbols in Field of View is set to 2, FLM will try to locate the candidates first and then decode. The symbols cannot be side-by-side--they must be parallel.
10-24
FIS-6300 ESD Imager User’s Manual
Page 249
Camera and IP Setup
Damaged Symbol Usage: Definition:
Usage: Default: Options:
This feature is useful with badly damaged symbols in which finder patterns or clock patterns are distorted, margins are distorted or missing on one or both sides of a symbol, or portions of data are damaged. When enabled, the Imager will make additional attempts and try different processes in order to decode the symbol. Due to the complexity of the algorithm required, enabling this feature could significantly increase decode time. <K519,damaged symbol status> Disabled 0 = Disabled 1 = Enabled
FIS-6300 ESD Imager User’s Manual
10-25
Page 250
IP Mode
IP Mode Definition:
Usage: Default: Options:
Standard uses 1/8th, 1/8th edge, and 1/4th binary images to locate. If narrow margin is enabled, it may also be necessary to try 2 x 1/8th binary image. The following conditions apply: • If only linear symbologies are enabled, only 1/8th and 1/8th edge are used. • If all linear symbologies are disabled and Damaged Symbol is disabled, 1/8th edge will be skipped. • If the number of symbols decoded does not satisfy the user-specified requirement, the Imager will erase the decoded symbols and proceed to the next image. <K527,IP Mode,FLM direction> Standard 0 = Standard 1 = Fast Linear Mode
Fast Linear Mode (FLM) Direction Definition:
Usage: Default: Options:
This mode assumes that the whole image is the candidate, and reads the image either horizontally or vertically. When the number of symbols in the field of view <K518> is set to 2, Fast Linear Mode will try to locate the candidates first and then decode. The candidate symbols cannot be side-by-side--they must be parallel. <K527,IP Mode,FLM direction> Auto 0 = Auto 1 = Horizontal 2 = Vertical
Auto FLM decides which direction to read based on Window of Interest dimensions. If the WOI height is greater than the width, the Imager reads vertically. Otherwise, it reads horizontally.
Horizontal This setting forces the Imager to read horizontally.
Vertical This setting forces the Imager to read vertically.
10-26