Page 231

Camera and IP Setup

Threshold (Histogram) Enable Autothreshold is checked by default. To adjust the threshold manually, 1. Uncheck the Enable Autothreshold box. 2. Move the threshold marker (vertical green dashed line) in the Histogram chart. Hint: This should be midway between the maximum and minimum curves. 3. Click on the Send Threshold button to adopt the new threshold position.

FIS-6300 ESD Imager User’s Manual

10-7

Page 232

Evaluation

Line Scan 1. From the Evaluation tab, click the Line Scan button. A window like that shown below will appear. 2. Drag your cursor horizontally across the image. This will create a dashed horizontal line. Pixel information and a visual representation of the dark and light pixels will be displayed below the image.

When you center your cursor over the dashed line, it becomes a double arrow cross. This allows you to move the line anywhere in the window. You can also use your keyboard arrows to move the line incrementally in any direction. As with the histogram, the line scan compares light and dark pixels, but in a spatial distribution. On the Y axis of the graph below, 0 is black and 255 is white; the X axis represents the horizontal axis of the symbol as described by the line scan. When you click anywhere on the graph, a vertical red line appears at that point and its position and value (in terms of black-to-white) are updated in the Pixel Info table to the left of the graph (237 in this example). In addition, a horizontal dashed red line is displayed that indicates the average value.

10-8

FIS-6300 ESD Imager User’s Manual

Page 233

Camera and IP Setup

Calibration The Calibration interface in ESP is a powerful and intuitive way to optimize the Imager’s performance. It allows the user to control several complex, simultaneous calibration operations, and to follow the progress of those operations using cues such as progress bars, real-time representations of calibration values, and other dynamic user feedback. See Calibration Options in Chapter 4 for full documentation of this feature.

ESP’s Calibration interface shown during a calibration routine.

FIS-6300 ESD Imager User’s Manual

ESP’s Calibration interface shown after a calibration routine.

10-9

Page 234

Window of Interest

Window of Interest The active pixel area of the image sensor is called the Window of Interest (WOI). The WOI allows the user to select an area of the field of view in which the desired symbol is located. The programmable window of interest increases decode speed, improves threshold, and makes it easy to select specific symbols from among several in the field of view. The user provides the upper-left pixel location and the size of the window to define the Window of Interest.

Caution: Window of Interest will shrink the field of view and therefore could cause symbols to be missed in dynamic applications.

10-10

FIS-6300 ESD Imager User’s Manual

Page 235

Camera and IP Setup

Window of Interest by ESP 1. From the Camera menu, click the WOI tab to bring up Window of Interest. If you haven’t already captured an image, click the Capture and Decode button to decode the present image. If successful, the Good Read indicator on the WOI tab will be green and the symbol will appear in the pane below. Note: You can resize the image by clicking and dragging the ESP window from the lower right corner. This is useful where very small symbols are being read. 2. Click and drag your cursor over the symbol that you want to isolate for reading. Notice that the surrounding area goes black. You can use the handles on the image area that you have just drawn to resize the region of interest. You can also click on the center of the window of interest and move it. 3. Test the new settings in Read Rate Mode.

Note: To remove the window of interest, click the Reset button or just click anywhere in the WOI pane. Note that all pixels not in the WOI are defined as black. Because the Imager has far less processing to do in a smaller window, read rates typically increase dramatically. One possible downside is that the chance of missing a symbol increases with the smaller window. Always verify that your WOI will be large enough to allow for any random movement of symbols in your field of view. FIS-6300 ESD Imager User’s Manual

10-11

Page 236

Window of Interest

Window of Interest by Serial Command The figure below shows where to locate the start position of the row and column pointers and how to measure the column depth and row width dimensions.

Top (Row Pointer) Definition: Defines the row position of the upper-left starting point of the window. Serial <K516,row pointer,column Cmd: pointer,row depth,column width> Default: 0 Options: 0 to (1024 - row depth)

WOI Row Pointer

WOI Column Pointer

WOI Row Depth

WOI Column Width

Left (Column Pointer) Definition: Serial Cmd: Default: Options:

Defines the column position of the upper-left starting point of the window. <K516,row pointer,column pointer,row depth,column width> 0 0 to (1280 - column width)

Important: The column pointer setting must be an even value. If a user enters an odd value, it will be decreased automatically to the nearest even value. For example, if a user enters a setting of 101, it will automatically be reduced to 100 (although a user request for this setting would still show 101).

Height (Row Depth) Definition: Serial Cmd: Default: Options:

Defines the size, in rows, of the window. Maximum value is defined as the maximum row size of the image sensor minus the Top value. <K516,row pointer,column pointer,row depth,column width> 1024 3 to (1024 - row pointer)

Width (Column Width) Definition: Serial Cmd: Default: Options:

Defines the column position of the upper-left starting point of the window. <K516,row pointer,column pointer,row depth,column width> 1280 8 to (1280 - column pointer)

Important: The column width value must be a modulus 8 value. If a user enters a nonmodulus 8 value, it will be decreased automatically to the nearest modulus 8 value. For example, if a user enters a setting of 639, it will automatically be reduced to 632 (although a user request for this setting would still show 639). 10-12

FIS-6300 ESD Imager User’s Manual

Page 237

Camera and IP Setup

Configuration Database The Configuration Database allows the user to manage multiple configuration profiles. It is a useful tool in applications that require several different Imager configurations to be applied sequentially, and it allows the user to perform far more complex operations than would be possible with only one set of configuration parameters. See Configuration Database Status in Chapter 11 for full documentation of this feature.

Configuration Database view, set for 5 Active Indexes, with Capture Settings highlighted.

FIS-6300 ESD Imager User’s Manual

10-13

Page 238

Dynamic Setup

Dynamic Setup Dynamic Setup is used to calculate image capture timing during a read cycle. Without proper timing, the Imager will not be able to decode all symbols in a read cycle. An external trigger is used to activate image captures so the user can make timing adjustments as capture events occur.

Read Rate is represented graphically in real-time as the user makes adjustments to the time delay between image captures. The user can control Capture #, Number of Captures, and Number of Symbols using these spin boxes.

The Delay Adjustment slider allows the user extremely precise control of the time delays between image captures in a read cycle. Delay values are shown in seconds in the field above the slider. The Coarse and Fine Delay Adjustment options determine whether larger or smaller adjustment increments will be used.

10-14

FIS-6300 ESD Imager User’s Manual

Page 239

Camera and IP Setup

Pixel Sub-Sampling Definition: Usage: Default: Options:

The camera can be enabled to sub-sample pixels in the specified image frame. Sub-sampling can be set to either 4:1 or 16:1. These ratios signify the sampling rate. <K542,sub-sampling> Disabled 0 = Disabled 1 = 4:1 2 = 16:1

4:1 At this sampling rate, 1 pixel is output for every 4 pixels sampled. The image will be sampled 2:1 vertically and 2:1 horizontally, for a combined 4:1 ratio. An image with dimensions of 640 x 480 will be scaled to 320 x 240.

16:1 At this sampling rate, 1 pixel is output for every 16 pixels sampled. The image will be sampled 4:1 vertically and 4:1 horizontally, for a combined 16:1 ratio. An image with dimensions of 640 x 480 will be scaled to 160 x 120.

FIS-6300 ESD Imager User’s Manual

10-15

Page 240

Camera

Camera Camera parameters are typically obtained during the calibration process, and do not necessarily need to be modified directly by the user.

Optics The FIS-6300 ESD Imager has three different optical configurations available: Standard Density, High Density, and Ultra High Density. Determine the optics of your Imager and find the corresponding camera values in the following sections.

Standard Density Optics, 4” Focal Distance Shutter Speed Usage:

Definition:

Serial Cmd: Default: Options:

Faster shutter speeds reduce blurring in faster applications. Slower shutter speeds are useful in slower applications and lower contrast applications. This value sets the exposure or integration time for the image sensor pixels. The shutter speed setting in relation to the speed of the object is critical. If a slow shutter speed is selected to capture fast-moving objects, blurring or smearing of the image will occur. As shutter speed is increased, more light and gain become necessary, because the pixels’ exposure time has decreased. <K541,shutter speed,gain> 250 (1/250 second) 15 to 10,000

Gain Usage: Definition:

Serial Cmd: Default: Options:

10-16

Can be used to adjust pixel grayscale values for readability. Sets the gain value for the image sensor. This setting can be configured through autocalibration, which is the recommended method. A higher gain value will increase the brightness of the image, but the visual noise reduction performance of the system is reduced. Before configuring gain settings, the desired shutter speed should already be set and the gain should be configured to optimize the shutter speed setting. <K541,shutter speed,gain> 20 0 to 48

FIS-6300 ESD Imager User’s Manual