Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 23 of 37

FIS-6300 ESD Imager User's Manual, pages 221 to 230

Pages 221 to 230 of 364

The original document is the PDF (5.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Wenglor FIS-6300

Page 221

Matchcode

Match Replace Usage: Definition: Serial Cmd: Default: Options:

Provides a convenient shortcut for applications that need to output a predefined text string whenever a symbol matches a master symbol. Outputs a user-defined data string whenever a match occurs and Matchcode is enabled. <K735,status,replacement string> Disabled 0 = Disabled 1 = Enabled

Replacement String Definition: Serial Cmd: Default: Options:

User-defined data string that, when enabled, replaces symbol data whenever a match occurs. <K735,status,replacement string> MATCH An ASCII string up to 64 characters.

Important: The ASCII characters <, >, and , can only be entered as hex pairs: For <: <K735h,,3C> For >: <K735h,,3E> For , : <K735h,,2C> See ASCII Character Entry Modifier on page 3-23 for a detailed explanation of how to enter ASCII characters as hex values.

FIS-6300 ESD Imager User’s Manual

9-9

Page 222

Mismatch Replace

Mismatch Replace Usage: Definition: Serial Cmd: Default: Options:

Provides a convenient shortcut for applications that need to output a predefined text string whenever a symbol does not match a master symbol. Outputs a user-defined data string whenever a mismatch occurs and Matchcode is enabled. <K736,status,replacement string> Disabled 0 = Disabled 1 = Enabled

Replacement String Definition: Serial Cmd: Default: Options:

User-defined data string that, when enabled, replaces symbol data whenever a mismatch occurs. <K736,status,replacement string> MISMATCH An ASCII string up to 64 characters.

Important: The ASCII characters <, >, and , can only be entered as hex pairs: For <: <K736h,,3C> For >: <K736h,,3E> For , : <K736h,,2C> See ASCII Character Entry Modifier on page 3-23 for a detailed explanation of how to enter ASCII characters as hex values.

9-10

FIS-6300 ESD Imager User’s Manual

Page 223

Matchcode

New Master Pin Definition:

Serial Cmd: Default: Options:

If Matchcode and New Master Pin are enabled and the new master pin is momentarily connected to ground (must be held low for a minimum of 10 mS) master symbol information will be loaded into the database based on the next read cycle that achieves a Good Read, starting with Index 1. The Master Symbol Database will be loaded with all symbols decoded in the read cycle as long as it does not exceed the Number of Master Symbols parameter. <K225,status> Disabled 0 = Disabled 1 = Enabled

New Master Load Status Definition:

Serial Cmd:

The new master status responds with the number of the next master position to be loaded, where 0 represents “idle” or “no master to be loaded.” Example: If the user has the Number of Master Symbols set to 1, and then either sends a <G> or toggles an active New Master Pin, the state will be 1, and prior to reading and effectively loading position 1, the response to <NEWM> would be <NEWM/1>. Once a symbol has been read and loaded, the status will be cleared: <NEWM/0>. <NEWM>

FIS-6300 ESD Imager User’s Manual

9-11

Page 224

New Master Pin

9-12

FIS-6300 ESD Imager User’s Manual

Page 225

10 Camera and IP Setup Contents Camera and IP Setup by ESP .................................................................................................... 10-2 Camera and IP Setup Serial Commands.................................................................................... 10-3 Video........................................................................................................................................... 10-4 Evaluation ................................................................................................................................... 10-5 Calibration................................................................................................................................... 10-9 Window of Interest .................................................................................................................... 10-10 Configuration Database ............................................................................................................ 10-13 Dynamic Setup ......................................................................................................................... 10-14 Pixel Sub-Sampling .................................................................................................................. 10-15 Camera ..................................................................................................................................... 10-16 Focal Distance .......................................................................................................................... 10-19 Focal Distance Table ................................................................................................................ 10-20 Increment Focus Position ......................................................................................................... 10-21 Decrement Focus Position........................................................................................................ 10-21 IP Threshold ............................................................................................................................. 10-22 Number of Symbols in Field of View......................................................................................... 10-24 Damaged Symbol ..................................................................................................................... 10-25 IP Mode .................................................................................................................................... 10-26 Hollow Mode ............................................................................................................................. 10-27 Mirrored Image ......................................................................................................................... 10-28 Illumination Brightness.............................................................................................................. 10-29

This section provides adjustment parameters for the physical controls of the camera, image acquisition, database settings, and image diagnostics.

FIS-6300 ESD Imager User’s Manual

10-1

Page 226

Camera and IP Setup by ESP

Camera and IP Setup by ESP

Click this button to bring up the Camera Setup menu.

To change a setting, double-click the setting and use your cursor to scroll through the options.

To open nested options, single-click the +.

10-2

FIS-6300 ESD Imager User’s Manual

Page 227

Camera and IP Setup

Camera and IP Setup Serial Commands IP Threshold <K512,threshold mode,fixed threshold value> Mirrored Image <K514,mirrored image> <K516,row pointer,column pointer,row depth,column width> Window of Interest Hollow Mode <K517,hollow mode status> Number of Symbols in Field of View <K518,number of symbols in field of view> Damaged Symbol <K519,damaged symbol status> Focal Distance <K525,focal distance> Increment Focus Position <525+> Decrement Focus Position <525-> Focal Distance Table <K526,number of focal distances,focal distance> IP Mode <K527,IP Mode,FLM direction> Illumination Brightness <K536,brightness> Camera <K541,shutter speed,gain> Pixel Sub-Sampling <K542,sub-sampling>

FIS-6300 ESD Imager User’s Manual

10-3

Page 228

Video

Video The Video view is similar to the EZ Mode interface, in that the user has the ability to perform the same Locate, Calibrate, and Test routines. There is also a focal distance adjustment tool to the right of the video view. Video also features Capture and Decode functionality, which is similar to the Configuration interfaces (Communication, Read Cycle, Symbologies, I/O, Matchcode, and Diagnostics).

Initiates Calibration routine.

Activates the Imager’s target pattern and initiates live video display of the symbol in the field of view.

Allows the user to take an image capture of the symbol in the field of view at any time, and to decode the symbol data. Similar to the Capture and Decode function in the Configuration views.

Initiates the Test routine. Allows the user to test the Imager’s read rate and decodes per second, and also displays decoded symbol data in the field at the bottom of the screen, Click Stop to end the Test routine.

Clicking this icon enables the focal distance slide control to the right of the video view. The focal distance value is displayed just below the icon.

Symbol data and Test results are shown in this field.

10-4

When enabled, shows the symbol in higher contrast than the default contrast value.

FIS-6300 ESD Imager User’s Manual

Page 229

Camera and IP Setup

Evaluation In Evaluation, you can view images currently in the Imager, capture and decode a symbol, save it as a digital file, and perform histogram and line scan evaluations. When you click on the Evaluation tab, you will see the images that are currently stored in the Imager. Click Receive to refresh this view. Click Capture/Decode to display the current stored image. Only one capture/ decode event will occur, regardless of read cycle settings. Click Read to trigger a read cycle. If there is enough time in the read cycle, up to 32 good reads (or 6 full-scale images) can be captured and displayed, depending on the size of the images, and depending on the number enabled in Number of Captures under Capture Mode in the Camera Setup menu tree to the left of the tabs. If you click Save, the current image will be saved to the location of your choice. Note: An image can only be saved in the format in which it was uploaded to ESP. JPEG images will be saved as .jpg, and bitmaps will be saved as .bmp. When you click the JPEG Image box, notice that the Line Scan button is grayed out. The JPEG option allows faster captures and transfers, but since the JPEG standard compresses image data, it is not suitable for the more rigorous demands of line scan evaluation. JPEG also allows you to adjust the image quality (resolution) by adjusting the sliding tab between 1 and 100, 1 being the lowest quality and 100 being the highest. When possible, use the highest quality; when image transfer speed must be increased, use a lower image quality setting. Adjustments for this setting will depend on your specific hardware and software limitations.

FIS-6300 ESD Imager User’s Manual

10-5

Page 230

Evaluation

Histogram Usage: Definition:

Useful in determining quality and contrast of symbols. A histogram is a graphic representation of the numeric count of the occurrence of each intensity (gray level) in an image. The horizontal axis represents the values of gray levels, and the vertical axis represents the number of pixels for each gray level.

Note: Since histograms are performed in the Imager, the results will be saved regardless of whether the image was uploaded as a JPEG (.jpg) or a bitmap (.bmp). 1. From the Evaluation window, click the Histogram button. The current image is transferred into the histogram operation. This may take a moment, since all the relevant pixels are being evaluated intensively. 2. When the Histogram window opens, you may need to expand the window and/or adjust the scroll bars in order to bring the image into view. 3. To generate a histogram, click and drag your cursor diagonally across the symbol or a portion of the symbol. The image will be surrounded by an “area of interest box”, a dashed blue line with red anchor points that can be selected and moved by placing a cursor inside the box, and can be resized by clicking and dragging the anchor points.

10-6

FIS-6300 ESD Imager User’s Manual