The text of a manual · part 30 of 37
FIS-6300 ESD Imager User's Manual, pages 291 to 300
Pages 291 to 300 of 364
The original document is the PDF (5.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Wenglor FIS-6300
Page 291
Utilities
Delete Master Symbol Data Definition: ESP:
You can directly delete the master symbol data by serial command or by ESP. 1. Click the Utilities button to access the master symbol. 2. Click the Master Database tab and double-click the symbol number you want to delete. 3. Delete text and click OK.
Serial Cmd:
<K231,master symbol number,> To delete a master symbol, enter the database number and a comma, but leave the data field empty. For example, to delete master symbol # 5, send the following: <K231,5,>. The command is entered with a blank master symbol data field, which tells the Imager to delete the selected master symbol from the database.
FIS-6300 ESD Imager User’s Manual
13-13
Page 292
Firmware
Firmware Firmware by ESP
Firmware Update Application code versions are specific to your Imager. Consult with your sales representative before downloading application code. If needed, an application code will be sent to you in the form of a *.mot file. To download application code: 1. First, be sure that your Imager is connected to the host. 2. Apply power to the Imager. 3. Before updating, you should verify the current firmware. 4. Click in the Firmware Update text box and select the file type you want to download. This will open a file locator box. 5. Navigate to the appropriate file (it will be a *.mot file) and open the file. Caution: Do not interrupt power or disconnect the host cable while download is in progress. Be sure that each download is complete before moving on to the next. Important: When updating firmware, be sure that the application code and boot code versions are mutually compatible.
13-14
FIS-6300 ESD Imager User’s Manual
Page 293
Utilities
Firmware Verification Request Part Number You can send a request to the Imager for part numbers, checksums, boot code, and application code.
By ESP You can access Part Numbers from the Utilities menu. 1. Click the Firmware tab. 2. From the pulldown selection box to the left of the Request Part No. button, make your selection. 3. Select the code type to see its part number displayed in the text field to the right of the Request Part No. button.
By Serial Command • When you send <#> (a request for all product part numbers), the Imager returns: <#b/BOOT_P/N><#a/APP_P/N><#p/PROFILE_P/N>. • When you send <#a> (a request for the application code part number), the Imager returns: <#a/APP_P/N>. • When you send <#b> (a request for the boot code part number), the Imager returns: <#b/BOOT_P/N>. • When you send <#p> (a request for profile module part numbers), the Imager returns: <#p/PROFILE_P/N>.
FIS-6300 ESD Imager User’s Manual
13-15
Page 294
Firmware
Request Checksum You can send a request to the Imager for part numbers, checksums, boot code, and application code.
By ESP You can access Checksum from the Utilities menu. 1. Click the Firmware tab. 2. From the pulldown selection box to the left of the Request Checksum button, make your selection. 3. Select the code type to see its checksum displayed in the text field to the right of the Request Checksum button.
By Serial Command • When you send <!> (a request for all available firmware checksums), the Imager returns: <!b/BOOT_CHECKSUM><!a/APP_CHECKSUM><!p/PROFILE_CHECKSUM> • When you send <!a> (a request for the application code checksum), the Imager returns: <!a/APP_CHECKSUM> • When you send <!b> (a request for the boot code checksum), the Imager returns: <!b/BOOT_CHECKSUM> • When you send <!p> (a request for profile module checksum), the Imager returns: <!p/PROFILE_CHECKSUM>
13-16
FIS-6300 ESD Imager User’s Manual
Page 295
Utilities
Bar Code Configuration Definition: Serial Cmd:
Bar Code Configuration Mode is a way of programming the Imager by using ECC 200 Data Matrix symbols. <BCCFG>
Bar Code Configuration Mode can be entered three different ways: 1. By forcing the Imager into Bar Code Configuration Mode by serial command <BCCFG>. 2. By configuring one of the 4 EZ button positions to Bar Code Configuration Mode. 3. By reading a Data Matrix symbol with a special code word used by ISO/IEC 16022 to signify Imager programming. This can be either in a regular read cycle or during a read rate test. Reading this symbol in the calibration routine will have no effect.1 Once Bar Code Configuration Mode has been entered, the Data Matrix symbols can be thought of as serial data. You can configure the Imager by printing labels in wenglor’s serial command format. Commands are processed as if the data were streamed in through the serial port. The Imager will acknowledge the symbol with a beep, green flash, and echo the serial data to the host. If the command causes the Imager to produce more serial output, such as serial verification or counter requests, the data will be routed to the host port. Bar Code Configuration Mode can be exited by any reset <A> or <Z> command as well as a <J> or a quick press and release of the EZ button. The command to exit Bar Code Configuration Mode can be included as part of the Data Matrix symbol. For example, try encoding <K200,4><K220,1><J> into a Data Matrix symbol. This configures the Imager to enable Serial Trigger Mode, to program a new trigger to end the read cycle, and to exit Bar Code Configuration Mode with <J>. To end all EZ button functions, press the EZ button once and quickly release.
1. In normal reading modes, it is required to read a special Data Matrix symbol with a special codeword used by ISO/IEC 16022 to signify Imager programming.
FIS-6300 ESD Imager User’s Manual
13-17
Page 296
Default / Reset / Save
Default / Reset / Save Understanding and controlling your Imager’s active, saved, and default settings is critical to its successful operation.
Saved for Power-on
Resets (not saved for power-on)
Function Reset
Serial Cmd <A>
Reset and recall wenglor defaults <Ard> Reset and recall power-on parameters <Arp> Reset and recall customer default <Arc> parameters
ESP (first, right click in any menu tree)a
EZ Button
Save to Reader, Send No Save No No
No No
No
No
Save to Reader, Send and Save Save to Reader, Send and Save Customer Defaults for Power-Onb
No
Save current settings for power-on
<Z>
Save current settings as customer default parameters for power-on
<Zc>
Recall wenglor default parameters and save for power-on
<Zrd>
No
No
Recall customer default parameters and save for power-on
<Zrc>
No
Press and hold while powering on Imager
No No a. When you right click in a menu tree and select Default Current Menu Settings or Default All ESP Settings, it is important to note that only ESP settings are defaulted. To save these defaults to the Imager itself, you need to follow up with a Save to Reader, Send and Save command.
b. Only available in ESP if enabled under the Options pulldown menu.
Resets Resets (“A” commands) affect only the current settings (active memory) and are not saved for power-on.
Saved for Power-on Power-on parameters (“Z” commands) are saved to NOVRAM and recalled and loaded into current parameters when power is cycled to the Imager or the <Arp> command is issued.
Defaults Defaults are wenglor firmware settings or saved customer settings that can be recalled, either by software or hardware reset.
13-18
FIS-6300 ESD Imager User’s Manual
Page 297
Utilities
Customer Default Parameters Customer default parameters (saved by <Zc>) are the same set of parameters as poweron parameters but are saved in a different, isolated section of NOVRAM. This allows a user essentially to create a backup set of parameters that can be recalled in the event that the current parameters or power-on parameters have been accidentally changed or are no longer desired. It is important to note that a hardware default does not affect customer default parameters. For example, a user that has inadvertently changed communication settings and saved them with a <Z> command, may not know the correct settings or have the capability to communicate within those settings. By first doing an EZ button default or hardware default to restore the known wenglor defaults, the user can then recall the previous customersaved settings with an <Arc> or <Zrc> command.
wenglor Default Parameters wenglor default parameters are contained in the firmware and cannot be changed.
Software Defaults wenglor default parameters can be recalled (loaded into current settings) with <Ard> command or recalled and saved for power-on with the <Zrd> command.
Hardware Default If a software default and reset is not possible, it may be necessary to reset the Imager by shorting (connecting) specific pins. This procedure has the same effect as the <Zrd> software command. Important: For this reset to occur, this command must be executed within 60 seconds of a power-on or a reset. 1. Apply power to the Imager. 2. If using an IB-131, locate pins 7 and 11 on the host connector. Caution: Be certain that the correct pins are located. Connecting the wrong pins could cause serious damage to the unit. 3. Momentarily connect these wires (or pins) and listen for a series of short beeps. 4. Within 3 seconds, connect them again. A longer beep should be heard. If not, repeat the process.
Default on Power-On You can also use the EZ button to default the Imager by holding it down while applying power to the Imager, provided that this feature is enabled.
FIS-6300 ESD Imager User’s Manual
13-19
Page 298
Imager Status Requests
Imager Status Requests <?> Status Byte The Imager responds to a status request <?> with a two character hex value, such as <?/22>. To determine status: 1. Look up the binary conversion in the table below. For example, the first hex 2 would be 0 0 1 0 in binary, as read from binary digits 3 through 0; the second hex 2 is also 0 0 1 0 as read from binary digits 7 through 4. 2. Next, enter your binary values from the table below in the “Binary” column next to the appropriate bit. Binary Bit 0 1 2 3 4 5
Binary 0 1 0 0 0 1
Hex Value
Imager Status Command error detected Command received Communication error detected Flash sector unprotect failure Host/Aux port buffer overflow Imager is in a read cycle
3. Under “Binary,” interpret 1s as true and 0s as not true. For example, bit 1 has a 1 in the “Binary” column, indicating “Command Received”. Bit 5 is also a 1, indicating that the “Imager is in a read cycle”.
<K?> All Status Request
0 1 2 3 4 5 6 7 8 9 A B C D E F
Bit Digits 7
6
5
4
3
2
1
0
0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1
0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1
0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1
0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1
This is the fastest way to learn the Imager’s current configuration. Sending this request will return the current settings of all commands, starting with the lowest K command value and ending with the highest K command value.
<K??> All Descriptor Status Request This request will return all current descriptors for every K command, starting with the lowest K command value and ending with the highest K command value.
<K?#> All Range Status Request This request will return the current settings of all commands within the user-defined range, starting with the lowest user-defined K command value and ending with the highest userdefined K command value.
13-20
FIS-6300 ESD Imager User’s Manual
Page 299
Utilities
<Knnn?> Single Status Request This request will return the value of the variables associated with the requested K command. The request of a single entry of a database command cannot exceed the number of database slots for the specific command.
<Knnn??> Single Descriptor Status Request This request returns the basic functional description of all fields in the requested K command.
<Knnn?#> Single Range Status Request This request will return the value range and storage type description of all fields in the requested K command.
FIS-6300 ESD Imager User’s Manual
13-21
Page 300
Imager Status Requests
Other Operational Serial Commands The following serial utility commands can be entered from ESP’s Terminal window or a PLC:
Y-Modem Upload Transfer Options <uy,path,filename>
Y-Modem Download Transfer Options <dy,path,filename>
Image Library Request <op,9> Manages files in a selected directory. File Source (Nothing) / /saved *.* /del /saved/del del*.*
13-22
Explanation All files in “root” directory All files in “root” directory All files in “saved” directory All files in all directories Deletes all files in the root director Deletes all files in the saved directory Deletes files in all directories
FIS-6300 ESD Imager User’s Manual