Page 181
I/O Parameters
Output Indicators The FIS-6300 ESD Imager has a beeper and three LED arrays, as follows: 1. A target pattern of blue LEDs for centering the field of view, which is projected from the front of the Imager . 2. An array of green LEDs projected from the front of the Imager that can be programmed to flash in response to user-defined conditions. 3. A row of five status LEDs on the side of the Imager.
Green Flash Mode Usage: Definition: Serial Cmd: Default: Options:
Used as a visual verification that a good read has occurred. An array of green LEDs in the front of the Imager can be programmed to flash in response to user-defined conditions. <K750,green flash mode,target pattern status,green flash duration> Good Read 0 = Disabled 1 = Good Read 2 = Static Presentation 3 = Match 4 = Mismatch 5 = Strobe
Disabled Green flash LEDs are disabled.
Good Read Green flash LEDs will flash when a good read condition is met or when Matchcode is enabled and a match occurs.
FIS-6300 ESD Imager User’s Manual
7-17
Page 182
Output Indicators
Static Presentation Mode Static Presentation Mode is used in conjunction with Continuous Read Mode: <K200,0>. When operating in Static Presentation Mode, the red LEDs will illuminate while the Imager is searching for a symbol in Continuous Read Mode. When a symbol is placed in the field of view and a good read occurs, the green LEDs will illuminate and stay on for the duration of time set in Green Flash Duration. Only one read will occur during that time unless more than one symbol is enabled in Number of Symbols. Note: If Static Presentation Mode is selected but the Imager is not in Continuous Read, the Green Flash will not occur. To use Static Presentation: 1. Enable Continuous Read. 2. Select the number of symbols. 3. Enable Static Presentation in Green Flash Mode. 4. Select the read time in Green Flash Duration.
Match The green LEDs will flash when a match condition is met. If multisymbol is enabled, then green flash LEDs will illuminate only if all symbols qualify as a match. If matchcode is disabled, then this mode will activate the LEDs on a good read.
Mismatch Same as Match, except that LEDs will illuminate on a mismatch.
Strobe Green flash LEDs will act as an illumination strobe for image capture. If it is required that the green flash LEDs be the only illumination for image capture, then the internal illumination LEDs can be disabled.
7-18
FIS-6300 ESD Imager User’s Manual
Page 183
I/O Parameters
Target Pattern Usage: Definition: Serial Cmd: Default: Options:
Assists users in positioning and locating symbols in the center of the Imager’s field of view. The user can control when the targeting system is ON or OFF, and can save this condition for power-on. <K750,green flash mode,target pattern status,green flash duration> Always Off 0 = Always Off 1 = ON when not in the read cycle 2 = ON when in the read cycle 3 = Always ON
Important: The targeting system actuated by the EZ button or operational command overrides this setting.
Always OFF The target pattern will remain OFF at all times unless overridden by the EZ button or operational command.
ON When Not in the Read Cycle The target pattern is always ON except during the read cycle. If the EZ button or operational command overrides this setting, the target pattern will remain on at all times.
ON When in the Read Cycle The target pattern will remain OFF except during the read cycle. If the EZ button or operational command overrides this setting, the target pattern will remain on at all times.
Always ON The target pattern is always ON.
FIS-6300 ESD Imager User’s Manual
7-19
Page 184
Output Indicators
Green Flash Duration Usage: Definition: Serial Cmd: Default: Options:
7-20
Provides visual verification that a good read has occurred. When a good read occurs, the green LEDs will illuminate and stay on for the time set in the Green Flash Duration value. <K750,green flash mode,target pattern status,green flash duration> 100 (1 second) 0 to 65535 (in 10mS increments)
FIS-6300 ESD Imager User’s Manual
Page 185
I/O Parameters
Beeper Usage: Definition: Serial Cmd: Default: Options:
An audible verification that either a good read or a noread has occurred. A beep is emitted after each good read or noread. <K702,beeper status> Good Read 0 = Disabled 1 = Good Read 2 = Noread
Note: The beeper will also sound at any of the following times: • When the Imager is defaulted. • When a send/save command is sent from ESP. • At the conclusion of a calibration procedure. • When a <Z>, <Zp>, <Zrd>, or <K701,,1> command is sent.
FIS-6300 ESD Imager User’s Manual
7-21
Page 186
LED Configuration
LED Configuration Usage: Definition: Serial Cmd: Default: Options:
Useful as a visible verification of read rates and symbol quality. Determines the mode in which the status LEDs operate. <K737,LED mode,ISO/IEC 16022 grade> Standard 0 = Standard 1 = ISO/IEC 16022 grade
In ISO/IEC 16022 grade mode the LEDs represent the grade of the first Data Matrix symbol decoded in the read cycle. The parameter to be graded is set in the ISO/IEC 16022 Grade options. For example, to program the LEDs to indicate the ISO/IEC 16022 print growth grade, set LED Mode to ISO/IEC 16022 Grade and set ISO/IEC 16022 Grade to Print Growth. If all the LEDs from 20% to 100% were illuminated, the read result would be a grade A; if only the 20% LED were illuminated, the result would be a grade F.
Standard In Standard Mode, the STATUS LED indicates read cycle status and the GOOD READ LED illuminates upon a good read at the end of a read cycle. In a read rate test, these LEDs represent the percentage of good reads per images captured.
ISO/IEC 16022 Grade Usage: Definition: Serial Cmd: Default: Options:
7-22
Provides visual grading of specific ISO/IEC 16022-related features. Determines which ISO/IEC 16022 feature the Imager will grade via the LEDs. <K737,LED mode,ISO/IEC 16022 grade> Final Grade 0 = Final Grade 1 = Symbol Contrast 2 = Print Growth 3 = UEC
FIS-6300 ESD Imager User’s Manual
Page 187
I/O Parameters
Serial Verification Allows the user to verify configuration command status.
Serial Command Echo Status Usage:
Definition:
Function:
Serial Cmd: Default: Options:
This command is useful in removing any doubt about the Imager’s interpretation of any configuration command. For example, if the current preamble is “SOM” and <K701,1,START> is entered, the Imager will echo back <K701,SOM> since the attempted entry “START” exceeds the four character limit for that command. Therefore, it is rejected and the existing “SOM” message is echoed back and remains the preamble message. When enabled, a configuration command received from the host is echoed back to the Host Imager host with the resultant settings. If a command with multiple fields is processed, some of the fields may have been processed properly while others were not. The changes will appear in the string echoed back so that the user will know which fields did or did not change. <K701,serial command echo status,serial command beep status,control/hex output> Disabled 0 = Disabled 1 = Enabled
Serial Command Beep Status Usage: Definition: Function:
Serial Cmd: Default: Options:
Used to audibly verify the acceptance and validity of a command. Causes the Imager to beep once whenever a K command is entered to indicate that the command was accepted and processed. If an invalid command is entered, the Imager beeps 5 times to indicate an invalid entry. However, this does not necessarily mean that all data fields have been entered incorrectly. Only one bad field needs to be found in order to activate the 5 beep response. <K701,serial command echo status,serial command beep status,control/hex output> Disabled 0 = Disabled 1 = Enabled
FIS-6300 ESD Imager User’s Manual
7-23
Page 188
Serial Verification
Control/Hex Output Usage: Definition:
Serial Cmd: Default: Options:
7-24
Useful for viewing settings with binary characters when using serial commands on a terminal. Determines the response to a Serial Command Echo or status request command. When set to Control, two characters are transmitted to represent a nondisplayable character. For example, a carriage return will be shown as: ^M. <K701,serial command echo status,serial command beep status,control/ hex output> Control 0 = Control 1 = Hex
FIS-6300 ESD Imager User’s Manual
Page 189
I/O Parameters
EZ Button The EZ button has four positions, selectable by the length of time the button is held down, and indicated by one, two, three, and four beeps in succession. Each position can be programmed for any of eight options. Definition: Serial Cmd: Default: Options:
Serves as a master switch to enable/disable the EZ button status. <K770,global status,default on power-on,load configuration database,save for power-on> Enabled 0 = Disabled 1 = Enabled 2 = Trigger 3 = Unlatch Outputs 4 = Parameter Switch
Disabled When set to Disabled, the EZ button does not function.
Enabled When selected, the EZ button is enabled and the function of each button position is selected by the EZ Button Mode command.
Trigger When selected, the EZ button acts as a trigger for the Imager to start and end read cycles. All other button operations are inactive. In External Level: In External Edge:
The read cycle endures for as long as the EZ button is pressed, unless a timeout occurs and Timeout is enabled for End of Read Cycle. As with Level, Edge allows a read cycle to be initiated by pressing the EZ button, but unlike Level, the read cycle ends with a good read output, a timeout, or a new trigger.
Unlatch Outputs In this configuration, the EZ button will unlatch any logic outputs that have been latched using the Latch Mode 1 (Unlatch on Input 1 Pin) operation.
Parameter Switch The parameter switch toggles between custom defaults and power-on settings. The condition is the same as that achieved by sending the <Arc> and <Arp> commands consecutively.
FIS-6300 ESD Imager User’s Manual
7-25
Page 190
EZ Button
Default on Power-On Definition: Serial Cmd: Default: Options:
When enabled, if the EZ button is held down on power-on the Imager will default to customer defaults and save for power-on. This is the same as sending a <Zrc> command. <K770,global status,default on power-on,load configuration database,save for power-on> Enabled 0 = Disabled 1 = Enabled
Load Configuration Database Definition:
Serial Cmd: Default: Options:
Allows the user to load the Configuration Database with calibration results. When the user performs a calibration using the EZ button, all the database entries are moved down one index and the results of the calibration are saved to index 0. The results will be saved as current settings as well. <K770,global status,default on power-on,load configuration database,save for power-on> Enabled 0 = Disabled 1 = Enabled
Save for Power-On Definition: Serial Cmd: Default: Options:
7-26
If enabled, after calibration is complete, all parameters will be saved for power-on. <K770,global status,default on power-on,load configuration database,save for power-on> Disabled 0 = Disabled 1 = Enabled