Page 191
I/O Parameters
EZ Button Modes Usage: Definition: Serial Cmd: Options:
Useful for performing multiple, repetitive tasks at the work site. Allows the user to program each of the EZ button’s 4 positions from a selection of 8 modes. <K771,position 1 mode,position 2 mode,position 3 mode,position 4 mode> 0 = Disabled 1 = Enabled
Single Beep 0 = Disabled 1 = Read Rate 2 = Calibrate 3 = Save for Power-On 4 = Unused 5 = Load New Master 6 = Unused 7 = Target System 8 = Bar Code Config.
Two Beeps 0 = Disabled 1 = Read Rate 2 = Calibrate 3 = Save for Power-On 4 = Unused 5 = Load New Master 6 = Unused 7 = Target System 8 = Bar Code Config.
Three Beeps 0 = Disabled 1 = Read Rate 2 = Calibrate 3 = Save for Power-On 4 = Unused 5 = Load New Master 6 = Unused 7 = Target System 8 = Bar Code Config.
Four Beeps 0 = Disabled 1 = Read Rate 2 = Calibrate 3 = Save for Power-On 4 = Unused 5 = Load New Master 6 = Unused 7 = Target System 8 = Bar Code Config.
Disabled When set to disabled, the associated button position will have no function associated with it, and the position will be skipped over.
Read Rate Read Rate will be initiated when the associated button position is selected. Read Rate will perform decodes/second and is the same as sending a <C> from the terminal. To exit Read Rate Mode quickly press and release the EZ button.
Calibrate Calibration will be initiated when the associated button position is selected. To abort calibration, quickly press and release the EZ button.
Save for Power-On All Imager settings will be saved to non-volatile memory to be recalled on power-on whenever the associated button position is selected. This is the same as sending a <Z> from the terminal.
Load New Master Functions in the same way as new master pin input whenever the associated button position is selected. The new master pin’s Consecutive Decode requirement holds true for this function. FIS-6300 ESD Imager User’s Manual
7-27
Page 192
EZ Button Modes
Target System Turns on the target pattern whenever the associated button position is selected. To disable, quickly press and release the EZ button. Note: This mode is the only one that does not require that the button be released before taking effect. Thus, as soon as the Imager beeps the appropriate number of times for the position, it will take effect. If it is necessary to have the target system on before another operation such as calibration or read rate is performed, ensure that the target system mode is assigned a lower position so that it will be activated first.
Bar Code Configuration Enables bar code configuration mode whenever the associated button position is selected. When enabled, the Imager can accept configuration commands from symbols. To disable, quickly press and release the EZ button.
EZ Button Operation To execute EZ button commands,
Single Beep (Position #1) Hold down button until a single beep is heard (and the 20% LED illuminates).
Two Beeps (Position #2) Hold down button until two quick beeps are heard (and the 20% and 40% LEDs illuminate.)
Three Beeps (Position #3) Hold down button until three quick beeps are heard (and the 20%, 40%, and 60% LEDs illuminate).
Four Beeps (Position #4) Hold down button until four quick beeps are heard (and the 20%, 40%, 60%, and 80% LEDs illuminate).
7-28
FIS-6300 ESD Imager User’s Manual
Page 193
I/O Parameters
Configurable Output 1
Usage: Definition: Serial Cmd: Default: Options:
This option provides discrete signalling to host software to control external devices such as PLCs and relays. It is useful for routing, sorting, and to prevent mis-packaging and mis-routing. Sets the discrete output functions for specific user-selected conditions. Allows the user to set the conditions under which an output (or outputs) will be activated. <K810,output on,output state,pulse width,output mode> Mismatch or Noread 0 = Mismatch or Noread 1 = Match (or good read) 3 = Noread 4 = Trend Analysis 6 = Diagnostic Warning 7 = In Read Cycle
2 = Mismatch 5 = Symbol Quality
Note: If Output On is set to Match or Mismatch, a transition (switching) will not occur unless Matchcode Type is enabled and a master symbol is loaded into memory.
Mismatch or Noread Activates discrete output when the data does not match that of the master symbol or the symbol has not been decoded before the end of the read cycle.
Match or Good Read Activates a discrete output when the symbol data matches the master symbol. Note: If you want to output for a good read and Matchcode is not enabled, you can enable any output for Match.
Mismatch Activates a discrete output whenever the symbol data does not match that of the master symbol.
Noread Activates a discrete output whenever the symbol data is not decoded before the end of the read cycle. FIS-6300 ESD Imager User’s Manual
7-29
Page 194
Configurable Output 1
Trend Analysis Usage: Definition:
Typically used when successful decodes are occurring but a discrete output is needed to flag a trend in quality issues. Activates discrete output when a trend analysis condition is met, depending on the trend analysis option enabled.
Symbol Quality Usage: Definition:
Typically used when a discrete indication is needed to flag a symbol quality condition. Activates discrete output when a symbol quality condition is met, depending on the symbol quality option enabled.
Diagnostic Warning Usage: Definition:
Typically used when a discrete indication of a diagnostic condition is needed. Activates discrete output when a diagnostic warning condition is met, depending on the diagnostic option enabled.
In Read Cycle Definition:
7-30
Activates a discrete output when the Imager is in a read cycle.
FIS-6300 ESD Imager User’s Manual
Page 195
I/O Parameters
Output State Definition: Serial Cmd: Default:
Sets the active electrical state of the discrete output. <K810,output on,output state,pulse width,output mode> Negative
Options:
0 = Negative
1 = Positive
Pulse Width Definition: Serial Cmd: Default: Options:
Sets the time in 10mS increments that the discrete output remains active. <K810,output on,output state,pulse width,output mode> 5 (Corresponds to 50 mS) 0 to 255 (0 to 2.55 seconds). Divide the number entered on the command line by 100 for time in seconds.
Output Mode Definition: Serial Cmd: Default:
Sets the condition in which the discrete output is de-activated. <K810,output on,output state,pulse width,output mode> Pulse
Options:
0 = Pulse 2 = Latch Mode 2
1 = Latch Mode 1 3 = Latch Mode 3
Pulse This is the default mode of operation in which the programmable output is activated when the Output On condition has been met and held active for the duration of the selected pulse width.
Latch Mode 1 (Unlatch on Input 1 Pin) The programmable output is active when the Output On condition has been met and held active until the discrete Input 1 has been activated.
Latch Mode 2 (Unlatch Opposite Condition) The programmable output is activated when the Output On condition has been met and held active until the opposite condition selected under Output On has been met. For example, if Noread is enabled under Output On, the programmable output will go active on a noread and remain active until the opposite condition, a good read, occurs.
Latch Mode 3 (Unlatch Re-enter Read Cycle) The programmable output is active when the Output On condition has been met and is held active until a new read cycle begins. Note: All of the Output On modes are inhibited when any Output on Warning is active for Output 1. FIS-6300 ESD Imager User’s Manual
7-31
Page 196
Configurable Output 1
Trend Analysis Output 1 Note: Output On under Output 1 Parameters must be set to Trend Analysis for this output to function.
Under Output 1 Parameters, expand the Trend Analysis tree:
Usage: Definition:
Example:
7-32
Useful in cases where the user doesn’t want to shut down for one condition but wants to monitor quality and read conditions. Applies Trend Analysis settings to Output 1. With Trend Analysis, the user can track the occurrences and frequency of mismatches, noreads, and the number of reads per trigger, and output the results to any of three outputs. Trend Analysis Mode = Noread Trigger Evaluation Period= 25 triggers (read cycles) Number to Output On = 4 In this example, the Imager will activate an output when 4 noreads occur within a period of 25 triggers (read cycles).
FIS-6300 ESD Imager User’s Manual
Page 197
I/O Parameters
Trend Analysis Mode Definition:
Sets the trend condition (Mismatch, Noread, or Decodes/Trigger) that will activate the output.
Serial Cmd:
<K780,trend analysis mode,trigger evaluation period,number to output on, decodes/trigger threshold> Noread
Default: Options:
0 = Mismatch 3 = Bad Symbol
1 = Noread 4 = No Symbol
2 = Decodes/Trigger
Mismatch Output will be activated when the number of mismatches equals the value entered for Number to Output On within the trigger window selected in Number of Triggers.
Noread Output will be activated when the number of noreads equals the value entered for Number to Output On within the trigger window selected in Number of Triggers.
Decodes/Trigger Output will be activated when the number of decodes equals the value entered for Number to Output On within the trigger window selected in Number of Triggers.
Bad Symbol Output will be activated when the number of Bad Symbol occurrences equals the value entered for Number to Output On within the trigger window selected in Number of Triggers.
No Symbol Output will be activated when the number of No Symbol occurrences equals the value entered for Number to Output On within the trigger window selected in Number of Triggers.
FIS-6300 ESD Imager User’s Manual
7-33
Page 198
Configurable Output 1
Trigger Evaluation Period Definition: Serial Cmd: Default:
The number of triggers to examine for the trend analysis condition. <K780,trend analysis mode,trigger evaluation period,number to output on, decodes/trigger threshold> 0
Options:
0 to 255
Number to Output On Usage:
Default:
Example: If Number to Output On is set to 3 and Trend Analysis Mode is set to Noread, then the output will not be activated until 3 noreads have occurred. Sets the number of Trend Analysis Mode events (mismatches, noreads, or reads/trigger as configured by Trend Analysis Mode) to occur within the trigger evaluation period before activating the associated output. <K780,trend analysis mode,trigger evaluation period,number to output on, decodes/trigger threshold> 0
Options:
0 to 255
Definition: Serial Cmd:
Decodes/Trigger Threshold Definition:
Default:
When set to this mode, and when the appropriate output is set to output on trend analysis, the Imager will function in a Decodes per Trigger mode during the read cycle and the trend analysis operation. Output will be activated based on whether or not the symbol decode count at the end of the read cycle crosses the decodes per trigger threshold. Note: Although this setup causes the Imager to function in a Decodes per Trigger mode, the decode count will only be appended to the symbol data if the status of the Decodes per Trigger command is enabled. <K780,trend analysis mode,trigger evaluation period,number to output on, decodes/trigger threshold> 0
Options:
0 to 65535
Serial Cmd:
7-34
FIS-6300 ESD Imager User’s Manual
Page 199
I/O Parameters
ISO/IEC 16022 Symbol Quality Output 1 Note: Output On under Output 1 Parameters must be set to Symbol Quality for this output to function.
Under Output 1 Parameters, expand the Symbol Quality (ISO/IEC 16022) tree.
Output on Symbol Contrast Usage: Definition:
Default:
Lets the user know if symbol quality is less than acceptable. If enabled, toggles Output 1 to an active state when Symbol Contrast Threshold is met. <K800,output on symbol contrast,symbol contrast threshold,output on print growth,print growth threshold,output on axial non-uniformity,axial non-uniformity threshold,output on UEC,UEC threshold> Disabled
Options:
0 = Disabled
Serial Cmd:
1 = Enabled
Output on Print Growth Usage: Definition:
Default:
Lets the user know if symbol quality is less than acceptable. If enabled, toggles Output 1 to an active state when Print Growth Threshold is met. <K800,output on symbol contrast,symbol contrast threshold,output on print growth,print growth threshold,output on axial non-uniformity,axial non-uniformity threshold,output on UEC,UEC threshold> Disabled
Options:
0 = Disabled
Serial Cmd:
FIS-6300 ESD Imager User’s Manual
1 = Enabled
7-35
Page 200
ISO/IEC 16022 Symbol Quality Output 1
Output on Axial Non-Uniformity Usage: Definition:
Default:
Lets the user know if symbol quality is less than acceptable. If enabled, toggles Output 1 to an active state when Axial Non-Uniformity Threshold is met. <K800,output on symbol contrast,symbol contrast threshold,output on print growth,print growth threshold,output on axial non-uniformity,axial non-uniformity threshold,output on UEC,UEC threshold> Disabled
Options:
0 = Disabled
Serial Cmd:
1 = Enabled
Output on Unused Error Correction Usage: Definition:
Default:
Lets the user know if symbol quality is less than acceptable. If enabled, toggles Output 1 to an active state when UEC Threshold is met. <K800,output on symbol contrast,symbol contrast threshold,output on print growth,print growth threshold,output on axial non-uniformity,axial non-uniformity threshold,output on UEC,UEC threshold> Disabled
Options:
0 = Disabled
Serial Cmd:
1 = Enabled
Symbol Contrast Threshold Usage: Definition: Serial Cmd: Default: Options:
7-36
Lets the user set the acceptable level of symbol quality. Conforms to ISO/IEC 16022 symbol quality grading (A,B,C,D). <K800,output on symbol contrast,symbol contrast threshold,output on print growth,print growth threshold,output on axial non-uniformity,axial non-uniformity threshold,output on UEC,UEC threshold> Grade C 0 = Grade A 3 = Grade D
1 = Grade B
2 = Grade C
FIS-6300 ESD Imager User’s Manual