Page 171
I/O Parameters
Linear Symbols: 1. Failed user defined minimum number of bars. 2. Failed to decode start/stop character (doesn’t apply to UPC, RSS, MicroPDF417, or Pharmacode). 3. Failed user defined minimum number of scan lines that qualify for the minimum number of bars. 4. Failed to decode. 5. Failed to decode UPC supplemental.
Noread Message Definition: Serial Cmd: Default: Options:
Any combination of ASCII characters can be defined as the noread message. <K714,noread message status,noread message> NOREAD A string of up to 64 characters.
Note: Noread Message will only be transmitted if Symbol Data Output is set to Match, Mismatch, or Good Read. Noread Message can be set to any ASCII character. Important: The ASCII characters <, >, and , can only be entered as hex pairs: For <: <K714h,,3C> For >: <K714h,,3E> For , : <K714h,,2C> See ASCII Character Entry Modifier on page 3-23 for a detailed explanation of how to enter ASCII characters as hex values.
FIS-6300 ESD Imager User’s Manual
7-7
Page 172
Bad Symbol Message
Bad Symbol Message Usage: Definition: Serial Cmd: Default: Options:
Useful in determining if a symbol is present and if user defined requirements for that symbol are met. Can tell the user if a qualified symbol is present but not decodable. Sets the requirements that will qualify an object or a symbol before outputting a decode or message. When enabled, sends a message to the host whenever an object meets the qualifications setup but is not decoded. <K715,[unused],message> BAD_SYMBOL Up to 64 ASCII characters.
Important: The ASCII characters <, >, and , can only be entered as hex pairs: For <: <K715h,,3C> For >: <K715h,,3E> For , : <K715h,,2C> See ASCII Character Entry Modifier on page 3-23 for a detailed explanation of how to enter ASCII characters as hex values.
No Symbol Message Usage: Definition: Serial Cmd: Default: Options:
Useful in determining if a symbol is present and if user defined requirements for that symbol are met. Can tell the user if an object does not qualify as a symbol. Sets the requirements that will qualify an object or a symbol before outputting a decode or message. When enabled, sends a message to the host whenever an object meets the qualifications setup but is not decoded. <K716,[unused],message> NO_SYMBOL Up to 64 ASCII characters.
Important: The ASCII characters <, >, and , can only be entered as hex pairs: For <: <K716h,,3C> For >: <K716h,,3E> For , : <K716h,,2C> See ASCII Character Entry Modifier on page 3-23 for a detailed explanation of how to enter ASCII characters as hex values.
7-8
FIS-6300 ESD Imager User’s Manual
Page 173
I/O Parameters
1D / Stacked Symbology Qualification Minimum Number of Bars Definition: Serial Cmd: Default: Options:
Sets the minimum number of bars to qualify linear symbols. <K717,minimum number of bars,minimum number of qualified scan lines,start/stop status> 0 0 to 255 (0 is disabled)
Minimum Number of Qualified Scan Lines Definition: Serial Cmd: Default: Options:
Sets the minimum number of scans that have the required number of bars set in Minimum Number of Bars. Important: This is a percentage value, from 0 to 100. <K717,minimum number of bars,minimum number of qualified scan lines,start/stop status> Disabled Any number from 0 to 100 (0 is disabled).
Start/Stop Status Definition: Serial Cmd: Default: Options:
When enabled, both Start and Stop characters need to be present to qualify as a decodable symbol. In the case of PDF417, only a Stop needs to be present. <K717,minimum number of bars,minimum number of qualified scan lines,start/stop status> Disabled 0 = Disabled 1 = Enabled
FIS-6300 ESD Imager User’s Manual
7-9
Page 174
2D Symbology Qualification
2D Symbology Qualification Note: In the cases where Symbol Size Status, Dimension Status, or Orientation Status is enabled, the Imager will always check the finder pattern regardless of Finder Patter Status setting.
Finder Pattern Status Definition: Serial Cmd: Default: Options:
Checks for the presence of a finder pattern. <K718,finder pattern status,symbol size mode,symbol size 1,symbol size 2,symbol size tolerance,dimension mode,dimension 1,dimension 2,dimension tolerance,orientation mode,orientation value> Disabled 0 = Disabled 1 = Enabled
Symbol Size Mode Note: If Symbol Size 1 is larger than Symbol Size 2, it will be automatically reversed in the algorithm. Definition: Serial Cmd: Default: Options:
Specifies the outputs resulting from the searches for Symbol Size 1 and Symbol Size 2. <K718,finder pattern status,symbol size mode,symbol size 1,symbol size 2,symbol size tolerance,dimension mode,dimension 1,dimension 2,dimension tolerance,orientation mode,orientation value> Disabled 0 = Disabled 1 = Bad/No Symbol Output 2 = Object Qualification 3 = Enable Both
Disabled Decoded messages are output, but no attempt to qualify symbols or output Bad or No Symbol messages is undertaken.
Bad/No Symbol Output Checks first for decodes. If no symbol is decoded, checks for symbol size. If both Symbol Size 1 and Symbol Size 2 requirements are met, a Bad Symbol message is output. If neither are met, a No Symbol message is output.
Object Qualification Checks first for matches to symbol size. If qualified, attempts to decode. If no decodes are found within the specified read cycle parameters, outputs a Noread message.
Enable Both Same as Object Qualification, except that if no objects qualify, then a No Symbol message is output; if at least one object qualifies, then a Bad Symbol message is output. 7-10
FIS-6300 ESD Imager User’s Manual
Page 175
I/O Parameters
Symbol Size 1 Definition: Serial Cmd: Default: Options:
Checks for symbol sizes for a specified number of elements. In the case of rectangular symbols, checks the longer side. <K718,finder pattern status,symbol size mode,symbol size 1,symbol size 2,symbol size tolerance,dimension mode,dimension 1,dimension 2,dimension tolerance,orientation mode,orientation value> 10 8 to 88 elements
Symbol Size 2 Definition: Serial Cmd: Default: Options:
Checks for symbol sizes for a specified number of elements. In the case of rectangular symbols, checks the shorter side. <K718,finder pattern status,symbol size mode,symbol size 1,symbol size 2,symbol size tolerance,dimension mode,dimension 1,dimension 2,dimension tolerance,orientation mode,orientation value> 10 8 to 88 elements
Symbol Size Tolerance Definition: Serial Cmd: Default: Options:
Sets the allowable deviation, up or down, for symbol sizes specified in Symbol Size 1 and Symbol Size 2. <K718,finder pattern status,symbol size mode,symbol size 1,symbol size 2,symbol size tolerance,dimension mode,dimension 1,dimension 2,dimension tolerance,orientation mode,orientation value> 2 0 to 10
FIS-6300 ESD Imager User’s Manual
7-11
Page 176
2D Symbology Qualification
Dimension Mode Definition: Serial Cmd: Default: Options:
Enables searches for symbol Dimension 1 and Dimension 2. <K718,finder pattern status,symbol size mode,symbol size 1,symbol size 2,symbol size tolerance,dimension mode,dimension 1,dimension 2,dimension tolerance,orientation mode,orientation value> Disabled 0 = Disabled 1 = Bad/No Symbol Output 2 = Object Qualification 3 = Enable Both
Disabled Decoded messages are output, but no attempt to qualify symbols or output Bad Symbol or No Symbol messages is undertaken.
Bad/No Symbol Output Checks first for decodes. If no symbol is decoded, checks for symbol dimension. If both Dimension 1 and Dimension 2 requirements are met, a Bad Symbol message is output. If neither are met, a No Symbol message is output.
Object Qualification Checks first for matches to symbol dimension. If qualified, attempts to decode. If no decodes are found within the specified read cycle parameters, outputs a Noread message.
Enable Both Same as Object Qualification, except that if neither Dimension 1 nor Dimension 2 qualifies, then a No Symbol message is output; if either Dimension 1 or Dimension 2 qualifies, then a Bad Symbol message is output.
7-12
FIS-6300 ESD Imager User’s Manual
Page 177
I/O Parameters
Dimension 1 Definition: Serial Cmd: Default: Options:
Checks symbol dimension for a specified number of pixels. In the case of rectangular symbols, checks the longer side. <K718,finder pattern status,symbol size mode,symbol size 1,symbol size 2,symbol size tolerance,dimension mode,dimension 1,dimension 2,dimension tolerance,orientation mode,orientation value> 0 0 to 1280 pixels
Dimension 2 Definition: Serial Cmd: Default: Options:
Checks symbol dimension for a specified number of pixels. In the case of rectangular symbols, checks the shorter side. <K718,finder pattern status,symbol size mode,symbol size 1,symbol size 2,symbol size tolerance,dimension mode,dimension 1,dimension 2,dimension tolerance,orientation mode,orientation value> 0 0 to 1024 pixels
Dimension Tolerance Definition: Serial Cmd: Default: Options:
Sets the allowable deviation, in percentage, for symbol sizes specified in Dimension 1 and Dimension 2. <K718,finder pattern status,symbol size mode,symbol size 1,symbol size 2,symbol size tolerance,dimension mode,dimension 1,dimension 2,dimension tolerance,orientation mode,orientation value> 10 0 to 100
FIS-6300 ESD Imager User’s Manual
7-13
Page 178
2D Symbology Qualification
Orientation Mode Definition: Serial Cmd: Default: Options:
Sets the orientation value. <K718,finder pattern status,symbol size mode,symbol size 1,symbol size 2,symbol size tolerance,dimension mode,dimension 1,dimension 2,dimension tolerance,orientation mode,orientation value> Disabled 0 = Disabled 1 = Bad/No Symbol Output 2 = Object Qualification 3 = Enable Both
Disabled Decoded messages are output, but no attempt is made to qualify symbols or to output Bad Symbol or No Symbol messages.
Bad/No Symbol Output Checks first for decodes. If no symbol is decoded, checks for symbol orientation. If Orientation Value is satisfied, a Bad Symbol message is output. If not satisfied, a No Symbol message is output.
Object Qualification Checks first for matches to symbol Orientation Value. If qualified, attempts to decode. If no decodes are found within the specified read cycle parameters, outputs a Noread message.
Enable Both Same as Object Qualification, except that if Orientation Value is satisfied but the symbol is not decoded, then a Bad Symbol message is output; if not satisfied, a Bad Symbol message is still output.
7-14
FIS-6300 ESD Imager User’s Manual
Page 179
I/O Parameters
Orientation Value Usage: Definition:
Instructs the Imager to ignore symbols not in the specified orientation. Sets the orientation of the symbol, in degrees clockwise from the default 0 orientation. “L” finder pattern For Data Matrix symbols, sets the (Data Matrix) finder “L” pattern, with the example to the right showing the default 0 orientation. For QR Code, sets the locator pattern (three squares), with the Three-square example to the right showing the finder pattern default 0 orientation. (QR Code) The other position settings will rotate clockwise from the defaults shown above.
Serial Cmd:
<K718,finder pattern status,symbol size mode,symbol size 1,symbol size 2,symbol size tolerance,dimension mode,dimension 1,dimension 2,dimension tolerance,orientation mode,orientation value> 0 0 to 359
Default: Options:
Note: A symbol’s orientation can miss the precise Orientation Value by several degrees and still be qualified. To be certain of the extent of the allowable tolerance, you should experiment with symbols in various orientations. In no case can they be more than 45° from the assigned orientation value and still be qualified.
FIS-6300 ESD Imager User’s Manual
7-15
Page 180
Read Duration Output
Read Duration Output Usage: Definition:
Useful in evaluating actual read cycle timing results, especially when initially setting up an application to determine maximum line speed (obtainable based on spacing between symbols.) When enabled the duration of the read cycle (in milliseconds) is appended to the symbol data. The read duration is the time from the beginning of the read cycle until data is output.
Read Duration Output Mode Serial Cmd: Default: Options:
<K706,status,separator> Disabled 0 = Disabled 1 = Enabled
Important: To measure the entire read cycle when in External Level trigger mode, set When to Output Symbol Data to End of Read Cycle. This output can measure over 49 days’ worth of duration; if exceeded, the “OVERFLOW” message will be output in place of the duration.
Read Duration Output Separator Definition: Serial Cmd: Default: Options:
User defined character that separates the symbol information from the Read Duration Output. <K706,status,separator> [space character] Any ASCII character.
Important: The ASCII characters <, >, and , can only be entered as hex pairs: For <: <K706h,,3C> For >: <K706h,,3E> For , : <K706h,,2C> See ASCII Character Entry Modifier on page 3-23 for a detailed explanation of how to enter ASCII characters as hex values.
7-16
FIS-6300 ESD Imager User’s Manual