Page 101

Read Cycle

End of Read Cycle Definition:

The read cycle is the time during which the Imager will attempt to capture and decode a symbol. A read cycle can be ended by a timeout, a new trigger, or by the last frame in a capture sequence or a combination of the above.

End of Read Cycle Mode Note: When operating in Continuous Read or Continuous Read 1 Output, the Imager is always in the read cycle. Serial Cmd: Default: Options:

<K220,end of read cycle,read cycle timeout> Timeout 0 = Timeout 1 = New Trigger 2 = Timeout or new Trigger 3 = Last Frame 4 = Last Frame or New Trigger

Timeout Usage:

Definition:

Typically used with Serial Data or External Edge and Continuous Read 1 Output. It is effective in highly controlled applications when the maximum length of time between objects can be predicted. It assures that a read cycle ends before the next symbol appears, giving the system extra time to decode and transmit the data to the host. Timeout ends the read cycle, causing the Imager to stop reading symbols and send the symbol data or noread message when the time set in Timeout elapses (times out), if When to Output is set to End of Read Cycle. If in Continuous Read 1 Output, a timeout initiates a new read cycle and allows the same symbol to be read again. With External Edge, Serial Data, or Serial Data or External Edge enabled, a timeout ends the read cycle and symbol data or a noread message is sent to the host. With External Level enabled, the read cycle does not end until the falling edge trigger occurs or a timeout occurs. The next read cycle does not begin until the next rising edge trigger.

FIS-6300 ESD Imager User’s Manual

5-15

Page 102

End of Read Cycle

New Trigger Usage: Definition:

New Trigger is an effective way to end a read cycle when objects move past the Imager at irregular intervals (not timing-dependent). New Trigger ends the current read cycle and initiates a new one when a new trigger occurs. New Trigger refers only to a rising edge trigger. With External Edge, Serial Data, or Serial Data or External Edge enabled, an edge or serial trigger ends a read cycle and initiates the next read cycle. In the case of External Level, a falling edge trigger ends the read cycle but the next read cycle does not begin until the occurrence of the next rising edge trigger.

Timeout or New Trigger Usage: Definition:

Useful in applications that require an alternative way to end the read cycle. For example, if an assembly line should stop completely or the intervals between objects are highly irregular. Timeout or New Trigger is identical to Timeout except that a timeout or a new trigger (whichever occurs first) ends the read cycle.

Last Frame Usage: Definition:

Useful in applications in which the number of captures needed can be defined but the timeout duration varies. Last Frame only applies to Rapid Capture Mode.

Last Frame or New Trigger Usage: Definition:

Useful in applications in which line speeds are irregular and a new labelled object could appear before the last frame in a Rapid Capture sequence. Last Frame or New Trigger is identical to New Trigger except that a new trigger or last frame (whichever occurs first) ends the read cycle.

Read Cycle Timeout Definition: Serial Cmd: Default: Options:

5-16

Read Cycle Timeout is the duration of the read cycle. <K220,end of read cycle,read cycle timeout> 200 (x10mS) 1 to 65535

FIS-6300 ESD Imager User’s Manual

Page 103

Read Cycle

Capture Mode Definition: Serial Cmd: Default: Options:

Capture Mode relates to the way that images are captured and processed. <K241,capture mode,number of captures,rapid capture mode,pre-processing> Continuous Capture 0 = Rapid Capture 1 = Continuous Capture

Rapid Capture Definition:

In a rapid capture mode, one or multiple captures (as many as 32) can be taken at an interval specified by the time-between-captures parameter. In this mode, the only limiting time factor is integration and transfer timing.

Continuous Capture Usage: Definition:

Continuous Capture is useful in applications with slower line speeds or where symbol spacing may be random or not time-dependent. In Continuous Capture Mode, image captures are taken throughout the read cycle in a multi-buffered format (see diagram below). The Imager begins processing the first captured image at the same time that it captures the second image. Captures will continue occurring throughout the read cycle until an end condition occurs, such as a timeout, a new trigger, the last frame in a capture sequence, or a combination of the above. Capture

Start of Read Cycle

1 2 3

4

5

End of read cycle

Processing time

Note: The Pre-Processing feature is automatically disabled when the Imager is in Continuous Capture Mode because multi-buffered formats perform better without pre-processing.

FIS-6300 ESD Imager User’s Manual

5-17

Page 104

Capture Mode

Number of Captures Usage: Definition: Serial Cmd: Default: Options:

Number of Captures is used to specify the number of captures to be processed in Rapid Capture Mode. Sets the total number of captures that are processed during a read cycle in Rapid Capture Mode. This feature is used in conjunction with Capture Timing parameters to specify the capture sequence of a rapid capture read cycle. <K241,capture mode,number of captures,rapid capture mode,pre-processing> 1 1 to 32

Note: The range of maximum number of captures is dynamic. This range is dependent on the maximum image size in the system. A full-size image (1280 x 1024) reduces the maximum number of images to 6. The smaller the image size, the greater the maximum number of captures. Once the image size is reduced to small enough dimensions, the maximum number of captures will be capped at 32. If a user enters a maximum capture value greater than that allowed, the value will be limited to the number of system images. This command also affects the number of stored images allowed in the system. If the maximum number of captures is selected, the number of stored images allowed will be 0.

Rapid Capture Mode Definition: Serial Cmd: Default: Options:

5-18

In Rapid Capture Mode, one or multiple captures (as many as 32) can be taken at an interval specified by the time-between-captures parameter. In this mode, the only limiting time factor is integration and transfer timing. <K241,capture mode,number of captures,rapid capture mode,pre-processing> Timed Capture 0 = Timed Capture 1 = Triggered Capture

FIS-6300 ESD Imager User’s Manual

Page 105

Read Cycle

Timed Capture Usage: Definition:

Timed Rapid Capture is useful in fast-moving applications in which symbols are only in the field of view for a short time and precise timing is required. In Timed Rapid Capture, decoding occurs independent of and simultaneous with capturing, thus allowing precise timing or no delay at all between captures. Also, consecutive captures are regarded as the same symbol if the output data is the same.

No Time Delay Between Captures

Start of Read Cycle

Diagram A n

End of read cycle

Time Before First Capture Time Delay Between Captures End of read cycle

Diagram B

Processing

FIS-6300 ESD Imager User’s Manual

5-19

Page 106

Triggered Capture Usage: Definition:

Useful in applications where each decode must be treated as a discrete event, regardless of symbol data. When Rapid Capture Mode is set to Triggered Capture, each decode is considered a separate event, even if the current decode data is identical to the previous decode data. The first trigger event starts the read cycle, and subsequent triggers will continue until the predetermined Number of Captures is met, or until the predetermined End of Read Cycle condition is met-- whichever occurs first. Note: If End of Read Cycle is set for New Trigger and the read cycle qualifications have not been met, the read cycle will only end once it receives the first trigger after reaching the predetermined Number of Captures setting. First trigger starts the read cycle

Captures on every trigger

Capture Read cycle ends on New Trigger or Timeout, as configured.

Processing

5-20

FIS-6300 ESD Imager User’s Manual

Page 107

Read Cycle

Pre-Processing Definition: Serial Cmd: Default: Options:

When enabled, this feature reduces the time between image capture and decode by beginning the processing task while an image is being captured. <K241,capture mode,number of captures,rapid capture mode,pre-processing> Enabled 0 = Disabled 1 = Enabled

Disabled When Pre-Processing is disabled, the Imager can process previously captured images while image capture events are taking place. The benefit of this operation is that the image capture events have minimal impact on image processing. Therefore, if the Imager is configured to capture 4 consecutive frames, but it is only looking for one decode, it could process and decode a symbol on the first image frame before all 4 image frames were captured. If PreProcessing were enabled, the Imager could not start processing an image frame until all 4 image frames were captured (since they are consecutive captures).

Enabled When Pre-Processing is enabled, the Imager performs pre-processing tasks while an image is being captured. Since some of the processing is complete when the image has been captured, the time required to complete the processing of the image frame will be less (approx. 10 mS/frame). However, while an image is being captured, the Imager is dedicated to operating on the current image being captured. This means that an image capture event will impact the processing time of previously captured image frames. The benefit of this mode is the decrease in capture-to-decode time.

FIS-6300 ESD Imager User’s Manual

5-21

Page 108

Capture Timing

Capture Timing Note: Capture Timing applies only to Rapid Capture Mode.

Time Before First Capture Usage: Definition: Serial Cmd: Default: Options:

In almost any moving line application, a time delay is needed to ensure that a symbol will be in the Imager’s field of view at the beginning of the capture sequence. Time Before First Capture in a moving line application is the time between an external trigger event and the occurrence of the first capture. <K242,time before 1st capture,time between capture 1 and capture 2,,,,,,,,time between capture 7 and capture 8> 0 0 to 65535 (2.097 seconds, in 32 µS increments)

Start of Read Cycle

Time Before First Capture Processing

5-22

FIS-6300 ESD Imager User’s Manual

Page 109

Read Cycle

Time Between Captures Usage: Definition: Serial Cmd:

Default: Options:

This is useful in applications where more than one symbol can appear during a single read cycle (multisymbol), or where line speeds are slow enough that captured frames might overlap or miss a symbol. A time delay can be inserted between individual frame captures in Rapid Capture Mode. <K242,time before 1st capture,time between captures [time 1,time 2,...time7] Entering 0s will result in no time between captures. Entering a different value in each field will vary the time delays accordingly. Note: You must enter time values along with comma separators for each field you want to change. If you omit fields, or enter only commas, the fields will remain as previously set. 0 0 to 65535 (2.097 seconds, in 32 µS increments)

Note: Number of Captures and number of frame delays (Time Between Captures) must be the same.

Start of Read Cycle

Diagram A

Time Delay Between Captures = 0 1 2 3 4 5

End of Read Cycle

Time Delay Between Captures varies.

Diagram B

FIS-6300 ESD Imager User’s Manual

5-23

Page 110

Image Processing Timeout

Image Processing Timeout Usage: Definition:

Serial Cmd: Default: Options:

Useful in higher speed applications where image processing time is long enough that not all captures have an opportunity to be processed. Specifies the maximum amount of time to process a captured image. When the timeout expires, the image processing is aborted. This timeout works in both Rapid Capture and Continuous Capture modes, as well as with the Configuration Database. <K245,image processing timeout> 5,000 mS (5 sec.) 1 to 65535 (in 1mS increments)

Notes: • The timeout period does not include capture time. • If a timeout occurs during processing and no symbols in the field of view have been decoded, the image will be recorded as a Noread. For this reason, a longer timeout should be tried to ensure that the symbol is decoded successfully.

5-24

FIS-6300 ESD Imager User’s Manual