Page 111
Read Cycle
Image Storage Image Storage Type Definition:
Serial Cmd: Default: Options:
Allows the user to store images from separate read cycles and to retrieve them later. The number of available slots for storage depends on the mode of operation. If the Imager is in Rapid Capture Mode, the number of images that can be stored is equivalent to the maximum number of the rapid count (the current rapid count setting). If the Imager is in Continuous Capture Mode, a number of images equivalent to the maximum number of the rapid count minus 3. <K244,image storage type,image storage mode> Disabled/Clear 0 = Disabled/Clear 1 = Store on Noread
Disabled / Clear Upon selection of this option, all saved images will be cleared and the Imager will not store images for later viewing.
Store on Noread This option will cause the Imager to store an image upon exiting the read cycle for retrieval at a later time. If multiple captures are present during the duration of a read cycle, the stored image will be the last image processed for that read cycle. This image is stored in RAM and can be retrieved as long as power is cycled to the Imager, and as long as the Imager has not been reset via a reset/save sequence. Other commands that can initialize storage in RAM are ones that change capture modes or put the Imager in a test capture mode.
Image Storage Mode Serial Cmd: Default: Options:
<K244,image storage type,image storage mode> First Mode 0 = First Mode 1 = Last Mode
First Mode This mode allows the Imager to store images until the available image memory has been filled. At that point the Imager will stop saving additional images. In this mode, you will always have the first image captured, because the saving process stops once memory has been filled.
Last Mode In this mode, image storage continues after available memory limits are reached. The oldest image in memory is overwritten, so you will always have the most recent stored image.
FIS-6300 ESD Imager User’s Manual
5-25
Page 112
Image Storage
Image Storage Example The following example assumes that the Imager is in a rapid capture mode of 3 captures. Number of Symbols: Frame # 1: Frame # 2: Frame # 3: Read Cycle Result: Stored Frame:
1 Noread Noread Good Read, Symbol # 1 Good Read None
Number of Symbols: Frame # 1: Frame # 2: Frame # 3: Read Cycle Result: Stored Frame:
1 Noread Noread Noread Noread Frame # 3
Number of Symbols: Frame # 1: Frame # 2: Frame # 3: Read Cycle Result: Stored Frame:
2 Noread Noread Good Read, Symbol # 1 Noread Frame # 2
5-26
FIS-6300 ESD Imager User’s Manual
Page 113
Read Cycle
Minimum Good Reads Definition: Serial Cmd: Default: Options:
This value specifies the number of times a symbol needs to be read to qualify as a good read. <K221,minimum good reads> 1 1 to 255
FIS-6300 ESD Imager User’s Manual
5-27
Page 114
Minimum Good Reads
5-28
FIS-6300 ESD Imager User’s Manual
Page 115
6 Symbologies Contents Symbologies by ESP.................................................................................................................... 6-2 Symbologies Serial Commands ................................................................................................... 6-3 Data Matrix ................................................................................................................................... 6-4 QR Code ...................................................................................................................................... 6-6 Code 39........................................................................................................................................ 6-7 Code 128 / EAN 128 .................................................................................................................. 6-10 BC412 ........................................................................................................................................ 6-13 Interleaved 2 of 5........................................................................................................................ 6-14 Code 93...................................................................................................................................... 6-17 Codabar...................................................................................................................................... 6-18 UPC / EAN ................................................................................................................................. 6-21 Pharmacode ............................................................................................................................... 6-25 RSS Expanded........................................................................................................................... 6-27 RSS Limited ............................................................................................................................... 6-28 RSS-14....................................................................................................................................... 6-28 PDF417 ...................................................................................................................................... 6-29 MicroPDF417 ............................................................................................................................. 6-31 Composite .................................................................................................................................. 6-32 Narrow Margins / Symbology ID................................................................................................. 6-33 Background Color....................................................................................................................... 6-35
This section describes the various symbol types that can be read and decoded by the FIS6300 ESD Imager. See http://www.aimglobal.org/standards/aimpubs.asp and http://www.gs1us.org/gs1us.html for additional information about symbologies.
FIS-6300 ESD Imager User’s Manual
6-1
Page 116
Symbologies by ESP
Symbologies by ESP
Click this button to bring up the Symbologies menu.
To change a setting, double-click the setting and use your cursor to scroll through the options.
To open nested options, single-click the +.
6-2
FIS-6300 ESD Imager User’s Manual
Page 117
Symbologies
Symbologies Serial Commands Narrow Margins/Symbology ID Background Color Composite Code 39 Codabar Interleaved 2 of 5 UPC/EAN Code 128/EAN 128
Code 93 PDF417 Pharmacode Data Matrix QR Code BC412 RSS-14 RSS Limited RSS Expanded MicroPDF417
<K450,narrow margin status,symbology identifier status> <K451,background color> <K453,symbology status,separator status,separator> <K470,status,check digit status,check digit output status,large intercharacter gap,fixed symbol length status,fixed symbol length,full ASCII set> <K471,status,start/stop match,start/stop output,large intercharacter gap,fixed symbol length status,symbol length,check digit type,check digit output> <K472,status,check digit status,check digit output status,symbol length #1, symbol length #2, guard bar status,range mode status> <K473,UPC status,EAN status,supplemental status,separator status,separator character,supplemental type,format UPC-E as UPC-A> <K474,status,fixed symbol length status,fixed symbol length,EAN 128 status,output format,application record separator status,application record separator character,application record brackets,application record padding> <K475,status,fixed symbol length status,symbol length> <K476,status,[unused],fixed symbol length status,fixed symbol length,[unused],codeword collection> <K477,status,fixed bar count status,fixed bar count,minimum bar count,bar width mode,direction,fixed threshold value> <K479,ECC 200 status, ECC 000 status,ECC 050 status, ECC 080 status,ECC 100 status,ECC 140 status,ECC 120 status,ECC 130 status> <K480,status> <K481,status,check digit output,fixed symbol length status,fixed symbol length> <K482,status> <K483,status> <K484,status,fixed symbol length status,fixed symbol length> <K485,status,[unused],fixed symbol length status,fixed symbol length>
FIS-6300 ESD Imager User’s Manual
6-3
Page 118
Data Matrix
Data Matrix Usage: Definition:
Very useful where information needs to be packed into a small area, and/ or where symbols need to be applied directly to the substrate with laser etching, chemical etching, dot peen, or other methods. Data Matrix is a type of Matrix symbology and has subsets ECC 000 - ECC 200. ECC 200 symbols have an even number of rows and an even number of columns. Most of the symbols are square with sizes from 10x10 to 144x144. Some symbols, however, are rectangular, with sizes from 8x18 to 16x48. All ECC 200 symbols can be recognized by the upper right corner module being light (binary 0) instead of dark.
ECC 200 Definition: Serial Cmd: Default: Options:
When enabled, will decode ECC 200 Data Matrix symbols. <K479,ECC 200 status,ECC 000 status,ECC 050 status,ECC 080 status,ECC 100 status,ECC 140 status,ECC 120 status,ECC 130 status> Enabled Note: This is the only symbol type enabled by default. 0 = Disabled
1 = Enabled
ECC 000 Definition: Serial Cmd: Default: Options:
When enabled, will decode ECC 000 symbols. <K479,ECC 200 status,ECC 000 status,ECC 050 status,ECC 080 status,ECC 100 status,ECC 140 status,ECC 120 status,ECC 130 status> Disabled 0 = Disabled
1 = Enabled
ECC 050 Definition: Serial Cmd: Default: Options:
6-4
When enabled, will decode ECC 050 symbols. <K479,ECC 200 status,ECC 000 status,ECC 050 status,ECC 080 status,ECC 100 status,ECC 140 status,ECC 120 status,ECC 130 status> Disabled 0 = Disabled
1 = Enabled
FIS-6300 ESD Imager User’s Manual
Page 119
Symbologies
ECC 080 Definition: Serial Cmd: Default: Options:
When enabled, will decode ECC 080 symbols. <K479,ECC 200 status,ECC 000 status,ECC 050 status,ECC 080 status,ECC 100 status,ECC 140 status,ECC 120 status,ECC 130 status> Disabled 0 = Disabled
1 = Enabled
ECC 100 Definition: Serial Cmd: Default: Options:
When enabled, will decode ECC 100 symbols. <K479,ECC 200 status,ECC 000 status,ECC 050 status,ECC 080 status,ECC 100 status,ECC 140 status,ECC 120 status,ECC 130 status> Disabled 0 = Disabled
1 = Enabled
ECC 140 Definition: Serial Cmd: Default: Options:
When enabled, will decode ECC 140 symbols. <K479,ECC 200 status,ECC 000 status,ECC 050 status,ECC 080 status,ECC 100 status,ECC 140 status,ECC 120 status,ECC 130 status> Disabled 0 = Disabled
1 = Enabled
ECC 120 Definition: Serial Cmd: Default: Options:
When enabled, will decode ECC 120 symbols. <K479,ECC 200 status,ECC 000 status,ECC 050 status,ECC 080 status,ECC 100 status,ECC 140 status,ECC 120 status,ECC 130 status> Disabled 0 = Disabled
1 = Enabled
ECC 130 Definition: Serial Cmd: Default: Options:
When enabled, will decode ECC 130 symbols. <K479,ECC 200 status,ECC 000 status,ECC 050 status,ECC 080 status,ECC 100 status,ECC 140 status,ECC 120 status,ECC 130 status> Disabled 0 = Disabled
FIS-6300 ESD Imager User’s Manual
1 = Enabled
6-5
Page 120
QR Code
QR Code Usage: Definition:
Serial Cmd: Default: Options:
6-6
Widely implemented in the automotive industry in Japan and throughout their worldwide supply chain. QR Code is capable of handling numeric, alphanumeric, and byte data as well as kanji and kana characters. Up to 7,366 characters (numeric data) can be encoded using this symbol. Therefore, less space is required to encode the same amount of data in a QR Code symbol than in a conventional symbol, lowering the cost of labelling. Three Position Detection Patterns in the symbol make omnidirectional, ultra-fast reading possible. QR Code has error protection capability. Data can often be restored even if a part of the symbol has become dirty or damaged. <K480,status> Disabled 0 = Disabled
1 = Enabled
FIS-6300 ESD Imager User’s Manual