Page 91

Read Cycle

Multisymbol Usage: Definition: Conditions:

Multisymbol is commonly used in shipping applications where a shipping symbol contains individual symbols for part number, quantity, etc. This feature allows on trigger to pick up all the symbols. Multisymbol allows the user to define up to 100 symbols that can be read in a single read cycle. The following conditions apply: • Each symbol must be different to be read, unless in Rapid Capture Mode, configured for “triggered capture”. • The maximum number of characters in a read cycle is 3,000 for all symbols. • All noread messages are posted at the end of the data string, unless output filtering is enabled. • If more than one symbol is within the field of view at the same time, symbol data may not be displayed in the order of appearance. • If Matchcode Type is set to Sequential or if Trigger is set to Continuous Read 1 Output, the Imager will behave as if Number of Symbols were set to 1, regardless of the user-defined configuration.

Number of Symbols Definition: Serial Cmd: Default: Options:

Number of Symbols is the number of different symbols that can be read in a single read cycle. <K222,number of symbols, multisymbol separator> 1 1 to 100

Multisymbol Separator Usage: Definition:

Used to delimit or separate data fields with a user defined character. Any valid ASCII character, inserted between each symbol read when Multisymbol is set to any number greater than 1. Serial Cmd: <K222,number of symbols,multisymbol separator> Default: , (comma) Options: Any available ASCII character. Important: The ASCII characters <, >, and , can only be entered as hex pairs: For <: <K222h,,3C> For >: <K222h,,3E> For , : <K222h,,2C> See ASCII Character Entry Modifier on page 3-23 for a more detailed explanation of how to enter ASCII characters as hex values. Note: If Noread messages are disabled and there are Noreads occurring, separators will only be inserted between symbol data outputs. FIS-6300 ESD Imager User’s Manual

5-5

Page 92

Trigger Mode and Duration

Trigger Mode and Duration Trigger Definition:

The event that will initiate the read cycle.

Note: When calibrating the Imager or testing read rate, the current trigger setting will be disregarded.

Trigger Mode Serial Cmd: Default: Options:

<K200,trigger mode,trigger filter duration> Continuous Read 0 = Continuous Read 1 = Continuous Read 1 Output 2 = External Level 3 = External Edge 4 = Serial Data 5 = Serial Data and External Edge

Continuous Read Usage: Definition:

Serial Cmd:

5-6

Continuous Read is useful in testing symbol readability or Imager functions. It is not recommended for normal operations. In Continuous Read, trigger input options are disabled, the Imager is always in the read cycle, and it will attempt to decode and transmit every capture. When to Output and Noread options have no affect on Continuous Read. <K200,0>

FIS-6300 ESD Imager User’s Manual

Page 93

Read Cycle

Continuous Read 1 Output Usage:

Definition:

Serial Cmd:

Continuous Read 1 Output can be useful in applications where it is not feasible to use a trigger and all succeeding symbols contain different information. It is also effective in applications where the objects are presented by hand. In Continuous Read 1 Output the Imager self-triggers whenever it decodes a new symbol or a timeout occurs. If End of Read Cycle is set to Timeout and the symbol doesn’t change, the output is repeated at the end of each timeout period. For example, if Timeout is set to one second, the Imager sends the symbol data immediately and repeats the output at intervals of one second for as long as it continues to capture the symbol. If End of Read Cycle is set to New Trigger, the Imager will send the current symbol data immediately, but only once. A new symbol appearing in the Imager’s range will be read and sent immediately, provided it is not identical to the previous symbol. <K200,1>

Caution: In automated environments, Continuous Read 1 Output is not recommended because there is typically no reliable way to verify that a symbol was missed. Note: If Trigger Mode is set to Continuous Read 1 Output, the Imager will behave as if Number of Symbols were set to 1, regardless of the user-defined configuration.

FIS-6300 ESD Imager User’s Manual

5-7

Page 94

Trigger Mode and Duration

External Level Initiate Read Cycle: Object #1, moving in front of the detector beam, causes a change in the trigger state, which initiates the read cycle. End Read Cycle: The same object, moving out of the detector beam, causes another change in the trigger state, which ends the read cycle.

Usage:

Definition:

Serial Cmd:

This mode is effective in an application where the speeds of the conveying apparatus are variable and the time the Imager spends reading each object is not predictable. It also allows the user to determine if a noread has occurred. External Level allows the read cycle (active state) to begin when a trigger (change of state) from an external sensing device is received. The read cycle persists until the object moves out of the sensor range and the active trigger state changes again. <K200,2>

Important: Level and Edge apply to the active logic state (Negative or Positive) that exists while the object is in a read cycle, between the rising edge and the falling edge. Rising edge is the trigger signal associated with the appearance of an object. Falling edge is the trigger signal associated with the subsequent disappearance of the object. This applies both to External Level and External Edge.

External Edge Initiate Read Cycle: Object # 1, moving in front of the detector beam, causes a change in the trigger state, which initiates the read cycle. Initiate Second Read Cycle: Object # 2, moving in front of the detector beam, causes another change in the trigger state. This signal initiates a new read cycle and ends the previous read cycle unless Timeout is enabled and a good read or timeout has not occured.

Usage: Definition:

Serial Cmd: 5-8

This mode is highly recommended in any application where conveying speed is constant, or if spacing, object size, or read cycle timeouts are consistent. External Edge, as with Level, allows the read cycle (active state) to begin when a trigger (change of state) from an external sensing device is received. However, the passing of an object out of sensor range does not end the read cycle. The read cycle ends with a good read output, or, depending on the End of Read Cycle setting, a timeout or new trigger occurs. <K200,3> FIS-6300 ESD Imager User’s Manual

Page 95

Read Cycle

Serial Data Usage: Definition:

Serial Cmd:

Serial Data is effective in a highly controlled environment where the host knows precisely when the object is in the field of view. It is also useful in determining if a noread has occurred. In Serial Data, the Imager accepts an ASCII character from the host or controlling device as a trigger to start a read cycle. A Serial Data trigger behaves the same as an External Edge trigger. Serial commands are entered inside angle brackets, as shown here: <t>. <K200,4>

Note: In Serial Data, sending a non-delimited start serial character will start a read cycle; however, a non-delimited stop serial character has no effect.

Serial Data or External Edge Usage:

Definition: Serial Cmd:

Serial Data or External Edge is seldom used but can be useful in an application that primarily uses an external sensing device but occasionally needs to be triggered manually. An auxiliary terminal can be connected to the auxiliary port so the user can send the serial trigger character through the Imager to the host. In this mode the Imager accepts either a serial ASCII character or an external trigger pulse to start the read cycle. <K200,5>

Note: In Serial Data, sending a non-delimited start serial character will start a read cycle; however, a non-delimited stop serial character has no effect.

FIS-6300 ESD Imager User’s Manual

5-9

Page 96

Trigger Mode and Duration

Trigger Filter Duration Usage: Definition: Serial Cmd: Default: Options:

Trigger Filter Duration allows the Imager to disregard false trigger events. When Trigger Mode is set to either External Edge or External Level, the read cycle’s active state must be delayed until the specified filter duration has elapsed. The Imager will trigger at the end of that duration. <K200,trigger mode,trigger filter duration> 313 (x 32µs = 10.24mS) 1 to 65535 (corresponding with 32µs to 2.097seconds in 32µs steps)

Note: If Trigger Mode is set to External Edge, the Imager will trigger only after the active state has been delayed for the specified filter duration. Note: If Trigger Mode is set to External Level, the Imager will trigger once the active state has been delayed for the specified filter duration after the appearance of an object’s active edge. In addition, the active state must be delayed for the specified filter duration after the disappearance of the object’s falling edge for the trigger to be rendered inactive.

5-10

FIS-6300 ESD Imager User’s Manual

Page 97

Read Cycle

External Trigger Polarity Usage: Definition: Serial Cmd: Default: Options:

Allows users to select the trigger polarity that will be used in their application. Determines the active state of the trigger signal applied to the cable input of the Imager. <K202,active state> Positive 0 = Negative 1 = Positive

FIS-6300 ESD Imager User’s Manual

5-11

Page 98

Serial Trigger

Serial Trigger Usage: Definition:

Allows the user to define the trigger character and delimiters that start and stop the read cycle. A serial trigger is considered an online host command and requires the same command format as all host commands. It must be entered within angle bracket delimiters < > or, in the case of non-delimited triggers, it must define individual start and stop characters.

Serial Trigger Character (delimited) Usage: Definition:

Allows the user to define the trigger character that initiates the read cycle. A single ASCII host serial trigger character that initiates the read cycle. A delimited trigger character is one that either starts or ends the read cycle and is enclosed by delimiters such as < >. Serial Cmd: <K201,serial trigger character> Default: Space bar Options: Any single ASCII character, including control characters, except NUL (00 in hex), an existing host command character, or an on-line protocol character. Control characters entered on the command line are displayed in the menu as mnemonic characters. Note: Serial Data or Serial Data or External Edge triggering mode must be enabled for Serial Trigger Character to take effect. Important: The ASCII characters <, >, and , can only be entered as hex pairs: For <: <K201h,3C> For >: <K201h,3E> For , : <K201h,2C> See ASCII Character Entry Modifier on page 3-23 for a detailed explanation of how to enter ASCII characters as hex values.

5-12

FIS-6300 ESD Imager User’s Manual

Page 99

Read Cycle

Start Trigger Character (non-delimited) Usage: Definition:

Serial Cmd: Default: Options:

Useful in applications where different characters are required to start a read cycle. A single ASCII host serial trigger character that starts the read cycle and is not enclosed by delimiters such as < and >. Non-delimited Start characters can be defined and will function according to the trigger event. When defining Start trigger characters, the following rules apply: • In External Edge the Imager looks only for the Start trigger character and ignores any Stop trigger character that may be defined. • In External Level the Start trigger character begins the read cycle and the Stop trigger character ends it. Note that even after a symbol has been decoded and the symbol data transmitted, the Imager remains in External Level trigger read cycle until a Stop character is received. • In Serial Data or External Edge trigger mode, either a Start trigger character or a hardware trigger can start an edge trigger read cycle. <K229,start character> NUL (00 in hex) (disabled) Two hex digits representing any ASCII character except XON and XOFF.

Important: The ASCII characters <, >, and , can only be entered as hex pairs: For <: <K229h,3C> For >: <K229h,3E> For , : <K229h,2C> See ASCII Character Entry Modifier on page 3-23 for a detailed explanation of how to enter ASCII characters as hex values.

FIS-6300 ESD Imager User’s Manual

5-13

Page 100

Stop Trigger Character (non-delimited)

Stop Trigger Character (non-delimited) Usage: Definition:

Serial Cmd: Default: Options:

Useful in applications where different characters are required to end a read cycle. A single ASCII host serial trigger character that ends the read cycle and is not enclosed by delimiters such as < and >. Non-delimited Stop characters can be defined and will function according to the trigger event. When defining Stop trigger characters, the following rules apply: • In External Edge the Imager looks only for the Start trigger character and ignores any Stop trigger character that may be defined. • In External Level the Start trigger character begins the read cycle and the Stop trigger character ends it. Note that even after a symbol has been decoded and the symbol data transmitted, the Imager remains in External Level trigger read cycle until a Stop character is received. • In Serial Data or External Edge trigger mode, either a Start trigger character or a hardware trigger can start an edge trigger read cycle. <K230,stop character> NUL (00 in hex) (disabled) Two hex digits representing an ASCII character.

Important: The ASCII characters <, >, and , can only be entered as hex pairs: For <: <K230h,3C> For >: <K230h,3E> For , : <K230h,2C> See ASCII Character Entry Modifier on page 3-23 for a detailed explanation of how to enter ASCII characters as hex values.

5-14

FIS-6300 ESD Imager User’s Manual