Page 54
Scanner Setup This section describes ESP’s four Setup interfaces: Calibration, Configuration Database, Ordered Output, and Output Format. Each interface allows the user to make changes to scanner configuration quickly and easily. Each interface allows the user to make changes to scanner configuration quickly and easily.
FIS-0870 Industrial Raster Scanner User’s Manual
4-1
Page 55
Calibration
Calibration The settings in the Calibration interface can also be configured using the <@> and <@CAL> serial commands, and the Calibration Options command. The Test and Calibrate features are also available in EZ Mode.
Click Save to save calibration settings, or Stop to cancel the calibration process.
4-2
Top Offset, Bottom Offset, Sweep and other raster functions can be set using the fields below, and top and bottom offset can also be set by clicking and dragging the edges of the laser arc in the picture.
Scan Speed, Gain, Tracking, Laser Power, and Raster Options can also be configured in the Reader Setup command.
FIS-0870 Industrial Raster Scanner User’s Manual
Page 56
Scanner Setup
Laser Off Position Percentage of the full scan arc that the scan beam moves through before the laser turns off. The combined values of Laser On Position and Laser Off Position cannot exceed 100 percent, the total arc of one scan. Laser Off Position must always exceed the value of Laser On Position for a scan to take place.
Laser Off Position
Laser On Position Percentage of the full scan arc that the scan beam moves through before the laser turns on. For example, if set to 30, the laser will be off during the first 30 percent of the scan. When Laser Framing is disabled, the laser is on for 100 percent of the full scan.
Laser On Position
FIS-0870 Industrial Raster Scanner User’s Manual
4-3
Page 57
Configuration Database
Configuration Database Configuration Database settings can also be configured by using the Configuration Database serial commands.
Double-clicking on an Index will bring up the Configuration Database Settings dialog.
Use the Number of Active Indexes field to determine how many database indexes will be used. Use the Number of Database Cycles to determine how many times the active indexes will be repeated. Use the Switch Timing field to determine the amount of time between active indexes.
4-4
FIS-0870 Industrial Raster Scanner User’s Manual
Page 58
Scanner Setup
Configuration Database Settings Double-clicking an Index will bring up the Configuration Database Settings dialog for that database index.
The settings shown above can be configured differently for every active index. Once all active database indexes are configured, the index can be concatenated and cycled for the number of times specified in Number of Database Cycles.
FIS-0870 Industrial Raster Scanner User’s Manual
4-5
Page 59
Ordered Output
Ordered Output Output filtering is a method of providing a set of good read qualifiers and also providing ordered output. There is a filter for up to the first 10 positions in a multisymbol output. The first filter corresponds to the first symbol output at the end of the read cycle. Each filter has settings for the following six parameters: Filter Number, Symbology Type, Length, Wildcard, Placeholder, Matching Data, Decode Direction, and Database Number.
Filter Number, Symbology Type, Length, Wildcard, Placeholder, and Matching Data are all displayed in the table below. Double-clicking on any row of the table will display the Ordered Output Filter Settings dialog, where settings can be changed.
Receive settings from the scanner, Send settings to the scanner, or Send and Save settings.
Number of Filters refers to the number of active output filters. 0 disables all output filters. Any non-zero numeral will enable output filtering to be performed using the filter indexes covered by this value. For example, if the number of filters is 5, then filter indexes 1, 2, 3, 4, and 5 will be applied.
Filter Number This is the filter index number that represents the position of the symbol in the data output at the end of the read cycle. This index number should be entered along with the following filter settings for the predetermined symbol position. 4-6
FIS-0870 Industrial Raster Scanner User’s Manual
Page 60
Scanner Setup
Symbology Type Specifies the symbology type allowed to occupy this location in multisymbol output. Note: To filter or order a symbol, the symbol must meet all the requirements of the selected filter index.
Length Specifies the length of the decoded symbol allowed to occupy this location in multisymbol output. Note: To filter or order a symbol, the symbol must meet all requirements of the selected filter index.
Wildcard This is the character to be used in the data output field when performing a data filter comparison. The wildcard character represents the end of matching, and allows for variable lengths of symbol output.
Placeholder The placeholder character requires a character to be present, but does not compare the data value.
FIS-0870 Industrial Raster Scanner User’s Manual
4-7
Page 61
Ordered Output
Matching Data This is the data string to be used when comparing symbol data for output filtering and ordering. This data string may also contain wildcard and placeholder characters to facilitate matching. Remember that in order to filter or order symbol data, it must meet all the requirements of the selected filter index. Examples: • Filter data = “123*”. This will match data strings of “123”, “123456”, and “123ABC”, but not “12”. • Filter data = “123*AB?C”. This will be interpreted as “123*”. • Filter data = “123?”. This will match “1234” and “123A”, but not “123”, “12345”, or “1234C”. • Filter data = “123?A”. This will match “1234A” and “123BA”, but not “123”, “1234C”, or “1234ABCD”. • Filter data = “123?A?”. This will match “1234AB” and “123BAT”, but not “1234A” or “123BATS”. • Filter data = “12??*”. This will match “1234”, “123456”, and “123ABC”, but not “12” or “123”. • Filter data = “123?A*”. This will match “1234A”, “123BA”, and “123BATS”, but not “1234” or “1234C”.
4-8
FIS-0870 Industrial Raster Scanner User’s Manual
Page 62
Scanner Setup
Ordered Output Filter Settings
Double-clicking on a row in the Ordered Output table brings up the Ordered Output Filter Settings dialog. Use these settings to determine Symbology Type, Length of the symbol, a user-defined Matching String, ASCII Lookup, Wildcard Character, Placeholder Character, Database Number, and Decode Direction. Click Apply to save the settings to the corresponding filter.
FIS-0870 Industrial Raster Scanner User’s Manual
4-9
Page 63
Ordered Output
Rules for Output Filter Configuration Output Filter Configuration Rule # 1 Each symbol that is decoded must match one of the filters before it can be saved to a read cycle record. There is an exception to this rule, however, when the number of symbols required for a read cycle exceeds the number of active filters. In such a case, unfiltered symbols can be placed into unfiltered output positions. For example, if the number of symbols required is 6 but there are only 5 active filters, the last position can be filled by any (unfiltered) qualified symbol. Output Filter Configuration Rule # 2 The same filter setup can be used multiple times. For example, filters 1, 2, and 3 can be set up to filter Code 39 symbols, and the output will occur in the order the symbols are decoded. Output Filter Configuration Rule # 3 All qualified symbols will be sorted and output in the matching filter position. If a symbol matches filter 3, it will be output as the third symbol. If a filter does not have a matching qualified symbol, a No Read message will be output in place of the symbol (assuming the No Read message is enabled). For example, if there is not a symbol that meets filter 3’s requirements, then a No Read message will be output in the third output position.
4-10
FIS-0870 Industrial Raster Scanner User’s Manual
Page 64
Scanner Setup
Output Format Enable Output Format This is a global enable/disable parameter. Use Set Number of Symbols and Output Phrase to assign symbols for formatting, and Symbol Parse to determine the specific output content for the assigned symbols. On the Output Format tab, check the Enable Output Format box.
FIS-0870 Industrial Raster Scanner User’s Manual
4-11
Page 65
Output Format
Set Number of Symbols Number of Symbols determines the number of symbols to which output formatting will apply.
Output Phrase Output Phrase refers to the user-defined Preamble, selected symbols, and Postamble sequence in the read cycle result. Use the Set Number of Symbols spin box to determine the number of symbols to be included in the output phrase.
Enter Postamble characters by double-clicking in the text field and then using the Postamble calculator.
4-12
Check the Parse boxes beneath the symbols to be formatted.
Enter Postamble characters by double-clicking in the text field and then using the Postamble calculator.
FIS-0870 Industrial Raster Scanner User’s Manual
Page 66
Scanner Setup
Symbol Parse Extract
The Extract Range function corresponds to the Start Location and Length parameters in the Format Extract serial command.
Multiple character sequences can be extracted and inserted using Symbol Parse. In this example, the selected extraction range is characters 2-4. The “Sample Symbol” example on the Symbol Parse dialog shows the selected character positions extracted and output as desired. Simultaneously, the data string from the selected symbol is displayed at the bottom left of the Parse Table, followed by the user-defined extracted output.
Output Index Output Index refers to the database entry to be modified with this command. A formatted output is built by extracting data from a symbol’s original data output and/or inserting user-defined characters. It may be helpful to think of individual indexes as positions in the final formatted output. Starting with index # 1, enter either an extract or insert command to begin building the desired output string. Then, with the next index number, enter either an extract or insert command to continue building the output string. Continue this process until the string is built.
Start Location Defines the location within the symbol data where the character extraction will begin. The first character extracted will also be the first character in the sequence displayed in user-defined output.
Length Defines the length (in consecutive characters) that will be extracted and placed in user-defined output. FIS-0870 Industrial Raster Scanner User’s Manual
4-13
Page 67
Output Format
Insert
The Insert process is very similar to the Extract process, except that Insert allows the user to enter characters using the Insert calculator (shown above).
Notice that Extract and Insert share the same Parse Table.
4-14
FIS-0870 Industrial Raster Scanner User’s Manual