The text of a manual · part 10 of 42
FIS-0870 Industrial Sweep Raster Scanner User's Manual: Scanner Parameters, pages 68 to 77
Pages 68 to 77 of 381, from FIS-0870 Industrial Sweep Raster Scanner User's Manual
The original document is the PDF (4.9 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Wenglor FIS-0870
Page 68
Scanner Parameters This section explains the function and purpose of the Parameters commands in ESP’s tabbed tree controls. Important: Unless otherwise specified, command settings shown in this section are the default settings.
FIS-0870 Industrial Raster Scanner User’s Manual
5-1
Page 69
Communication
Communication Click the App Mode button and then the Parameters button to display the tree control tabs. Then click the Communication tab to display the Communication tree control.
The * indicates that the setting is the default.
To open nested options, single-click the +.
To change a setting, double-click the setting and use the cursor to scroll through the options.
Note: Communication settings can also be sent to the scanner from ESP’s Terminal using Wenglor’s K command format. Refer to Communication.
5-2
FIS-0870 Industrial Raster Scanner User’s Manual
Page 70
Scanner Parameters
Port Routing The FIS-0870 features a communication system based on Port Routing instead of traditional, dedicated serial ports. Decisions can be made about the direction and content of communication between ports based on different Data Types. Any available port can be used in any combination. The fundamental concept of Port Routing is that communication design can be based upon Data Types rather than ports. The advantage of this is the ability to map different data types to different ports - the user is no longer limited to a “Host Port” and “Aux Port” for specific types of input and output. Since each port is independent instead of fixed for a particular purpose, the scanner behaves more like a data switch.
Port Routing Advantages • Data can be routed in on one port and out on the same port or a different port like a switch or router. Transparent Mode, Half Duplex Mode, Full Duplex Mode, and Custom Mode. • External Data Routing still follows the “To/From Host/Aux” paradigm. The new capability allows the customer to define the data direction - which port behaves as the “Host Port” and which port behaves as the “Aux Port”. • Only one daisy chain setup required per system. • Minimal configuration required for each port, with similar items grouped together.
FIS-0870 Industrial Raster Scanner User’s Manual
5-3
Page 71
Communication
RS-232 A The following settings define the basic transmission speeds and digital standards that ensure common RS-232 formatting.
Baud Rate Can be used to transfer data faster or to match host port settings. The rate at which the scanner and host transfer data back and forth.
Parity Only changed if necessary to match host setting. An error detection routine in which one data bit per character is set to 1 or 0 so that the total number of bits in the data field is either even or odd.
Stop Bits Only changed if necessary to match host setting. One or two bits added to the end of each character to indicate the end of the character.
5-4
FIS-0870 Industrial Raster Scanner User’s Manual
Page 72
Scanner Parameters
Data Bits Only changed if necessary to match host setting. One or two bits added to the end of each character to indicate the end of the character.
Symbol Data Output Enables or disables decoded symbol data output from the scanner.
Extra Symbol Information Enables or disables extra symbol information output from the scanner.
Diagnostics Output Enables or disables diagnostics output from the scanner.
FIS-0870 Industrial Raster Scanner User’s Manual
5-5
Page 73
Communication
External Source Processing Mode Enables or disables processing of commands or data from sources external to the scanner.
Command Command enables command processing in the scanner. Note: Command processing is always enabled for RS-232 A.
Data Data enables RS-232 A as a data source port. Note: The data path between in the source port and out the source port is always two-way. Data is copied from source data ports and all those source ports’ data is transmitted to the destination port, and from the destination port to the source port.
5-6
FIS-0870 Industrial Raster Scanner User’s Manual
Page 74
Scanner Parameters
RS-232 B The following settings define the basic transmission speeds and digital standards that ensure common RS-232 formatting.
Baud Rate Can be used to transfer data faster or to match host port settings. The rate at which the scanner and host transfer data back and forth.
Parity Only changed if necessary to match host setting. An error detection routine in which one data bit per character is set to 1 or 0 so that the total number of bits in the data field is either even or odd.
Stop Bits Only changed if necessary to match host setting. One or two bits added to the end of each character to indicate the end of the character.
FIS-0870 Industrial Raster Scanner User’s Manual
5-7
Page 75
Communication
Data Bits Only changed if necessary to match host setting. One or two bits added to the end of each character to indicate the end of the character.
Symbol Data Output Enables or disables decoded symbol data output from the scanner.
Extra Symbol Information Enables or disables extra symbol information output from the scanner.
Diagnostics Output Enables or disables diagnostics output from the scanner.
5-8
FIS-0870 Industrial Raster Scanner User’s Manual
Page 76
Scanner Parameters
External Source Processing Mode Enables or disables processing of commands or data from sources external to the scanner.
Command Command enables command processing in the scanner.
Data Data enables RS-232 B as a data source port. Note: The data path between in the source port and out the source port is always two-way. Data is copied from source data ports and all those source ports’ data is transmitted to the destination port, and from the destination port to the source port.
FIS-0870 Industrial Raster Scanner User’s Manual
5-9
Page 77
Communication
RS-422 The following settings define the basic transmission speeds and digital standards that ensure common RS-422 formatting.
Baud Rate Can be used to transfer data faster or to match host port settings. The rate at which the scanner and host transfer data back and forth.
Parity Only changed if necessary to match host setting. An error detection routine in which one data bit per character is set to 1 or 0 so that the total number of bits in the data field is either even or odd.
Stop Bits Only changed if necessary to match host setting. One or two bits added to the end of each character to indicate the end of the character.
5-10
FIS-0870 Industrial Raster Scanner User’s Manual