Page 78

Scanner Parameters

Data Bits Only changed if necessary to match host setting. One or two bits added to the end of each character to indicate the end of the character.

Symbol Data Output Enables or disables decoded symbol data output from the scanner.

Extra Symbol Information Enables or disables extra symbol information output from the scanner.

Diagnostics Output Enables or disables diagnostics output from the scanner.

FIS-0870 Industrial Raster Scanner User’s Manual

5-11

Page 79

Communication

External Source Processing Mode Enables or disables processing of commands or data from sources external to the scanner.

Command Command enables command processing in the scanner.

Data Data enables RS-422 as a data source port. Note: The data path between in the source port and out the source port is always two-way. Data is copied from source data ports and all those source ports’ data is transmitted to the destination port, and from the destination port to the source port.

5-12

FIS-0870 Industrial Raster Scanner User’s Manual

Page 80

Scanner Parameters

Ethernet Status Enables or disables Ethernet connectivity in the scanner. Important: For further information about setting up TCP/IP with a PC, see Configuring Ethernet TCP/IP.

FIS-0870 Industrial Raster Scanner User’s Manual

5-13

Page 81

Communication

IP Address Enter the IP address of the scanner in this field.

5-14

FIS-0870 Industrial Raster Scanner User’s Manual

Page 82

Scanner Parameters

Subnet Enter the Subnet address of the scanner in this field.

FIS-0870 Industrial Raster Scanner User’s Manual

5-15

Page 83

Communication

Gateway Enter the Gateway address of the scanner in this field.

5-16

FIS-0870 Industrial Raster Scanner User’s Manual

Page 84

Scanner Parameters

IP Address Mode Determines how the scanner’s IP address will be defined.

Static In Static Mode, the scanner uses the user-defined IP address entered in ESP.

DHCP In DHCP Mode, the scanner automatically acquires the IP address, Subnet, and Gateway addresses from a DHCP or BOOTP server.

FIS-0870 Industrial Raster Scanner User’s Manual

5-17

Page 85

Communication

TCP Port 1 One of two TCP ports for Ethernet communication with the scanner. The default setting is 2001.

Symbol Data Output Enables or disables decoded symbol data output from the scanner.

Extra Symbol Information Enables or disables extra symbol information output from the scanner.

Diagnostics Output Enables or disables diagnostics output from the scanner.

External Source Processing Mode Enables or disables processing of commands or data from sources external to the scanner. Command Command enables command processing in the scanner. Data Data enables Ethernet TCP Port 1 as a data source port. Note: The data path between in the source port and out the source port is always two-way. Data is copied from source data ports and all those source ports’ data is transmitted to the destination port, and from the destination port to the source port. 5-18

FIS-0870 Industrial Raster Scanner User’s Manual

Page 86

Scanner Parameters

TCP Port 2 One of two TCP ports for Ethernet communication with the scanner. The default setting is 2003.

Symbol Data Output Enables or disables decoded symbol data output from the scanner.

Extra Symbol Information Enables or disables extra symbol information output from the scanner.

Diagnostics Output Enables or disables diagnostics output from the scanner.

External Source Processing Mode Enables or disables processing of commands or data from sources external to the scanner. Command Command enables command processing in the scanner. Data Data enables Ethernet TCP Port 2 as a data source port. Note: The data path between in the source port and out the source port is always two-way. Data is copied from source data ports and all those source ports’ data is transmitted to the destination port, and from the destination port to the source port. FIS-0870 Industrial Raster Scanner User’s Manual

5-19

Page 87

Communication

EtherNet/IP Enables or disables EtherNet/IP operation in the scanner. Important: See Using EtherNet/IP, for detailed information about implementing EtherNet/IP in an application.

Symbol Data Output Enables or disables decoded symbol data output from the scanner.

Extra Symbol Information Enables or disables extra symbol information output from the scanner.

Diagnostics Output Enables or disables diagnostics output from the scanner.

External Source Processing Mode Enables or disables processing of commands or data from sources external to the scanner. Command Command enables command processing in the scanner. Data Data enables EtherNet/IP as a data source port. Note: The data path between in the source port and out the source port is always two-way. Data is copied from source data ports and all those source ports’ data is transmitted to the destination port, and from the destination port to the source port. 5-20

FIS-0870 Industrial Raster Scanner User’s Manual