The text of a manual · part 11 of 42
FIS-0870 Industrial Sweep Raster Scanner User's Manual: Scanner Parameters, pages 78 to 87
Pages 78 to 87 of 381, from FIS-0870 Industrial Sweep Raster Scanner User's Manual
The original document is the PDF (4.9 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Wenglor FIS-0870
Page 78
Scanner Parameters
Data Bits Only changed if necessary to match host setting. One or two bits added to the end of each character to indicate the end of the character.
Symbol Data Output Enables or disables decoded symbol data output from the scanner.
Extra Symbol Information Enables or disables extra symbol information output from the scanner.
Diagnostics Output Enables or disables diagnostics output from the scanner.
FIS-0870 Industrial Raster Scanner User’s Manual
5-11
Page 79
Communication
External Source Processing Mode Enables or disables processing of commands or data from sources external to the scanner.
Command Command enables command processing in the scanner.
Data Data enables RS-422 as a data source port. Note: The data path between in the source port and out the source port is always two-way. Data is copied from source data ports and all those source ports’ data is transmitted to the destination port, and from the destination port to the source port.
5-12
FIS-0870 Industrial Raster Scanner User’s Manual
Page 80
Scanner Parameters
Ethernet Status Enables or disables Ethernet connectivity in the scanner. Important: For further information about setting up TCP/IP with a PC, see Configuring Ethernet TCP/IP.
FIS-0870 Industrial Raster Scanner User’s Manual
5-13
Page 81
Communication
IP Address Enter the IP address of the scanner in this field.
5-14
FIS-0870 Industrial Raster Scanner User’s Manual
Page 82
Scanner Parameters
Subnet Enter the Subnet address of the scanner in this field.
FIS-0870 Industrial Raster Scanner User’s Manual
5-15
Page 83
Communication
Gateway Enter the Gateway address of the scanner in this field.
5-16
FIS-0870 Industrial Raster Scanner User’s Manual
Page 84
Scanner Parameters
IP Address Mode Determines how the scanner’s IP address will be defined.
Static In Static Mode, the scanner uses the user-defined IP address entered in ESP.
DHCP In DHCP Mode, the scanner automatically acquires the IP address, Subnet, and Gateway addresses from a DHCP or BOOTP server.
FIS-0870 Industrial Raster Scanner User’s Manual
5-17
Page 85
Communication
TCP Port 1 One of two TCP ports for Ethernet communication with the scanner. The default setting is 2001.
Symbol Data Output Enables or disables decoded symbol data output from the scanner.
Extra Symbol Information Enables or disables extra symbol information output from the scanner.
Diagnostics Output Enables or disables diagnostics output from the scanner.
External Source Processing Mode Enables or disables processing of commands or data from sources external to the scanner. Command Command enables command processing in the scanner. Data Data enables Ethernet TCP Port 1 as a data source port. Note: The data path between in the source port and out the source port is always two-way. Data is copied from source data ports and all those source ports’ data is transmitted to the destination port, and from the destination port to the source port. 5-18
FIS-0870 Industrial Raster Scanner User’s Manual
Page 86
Scanner Parameters
TCP Port 2 One of two TCP ports for Ethernet communication with the scanner. The default setting is 2003.
Symbol Data Output Enables or disables decoded symbol data output from the scanner.
Extra Symbol Information Enables or disables extra symbol information output from the scanner.
Diagnostics Output Enables or disables diagnostics output from the scanner.
External Source Processing Mode Enables or disables processing of commands or data from sources external to the scanner. Command Command enables command processing in the scanner. Data Data enables Ethernet TCP Port 2 as a data source port. Note: The data path between in the source port and out the source port is always two-way. Data is copied from source data ports and all those source ports’ data is transmitted to the destination port, and from the destination port to the source port. FIS-0870 Industrial Raster Scanner User’s Manual
5-19
Page 87
Communication
EtherNet/IP Enables or disables EtherNet/IP operation in the scanner. Important: See Using EtherNet/IP, for detailed information about implementing EtherNet/IP in an application.
Symbol Data Output Enables or disables decoded symbol data output from the scanner.
Extra Symbol Information Enables or disables extra symbol information output from the scanner.
Diagnostics Output Enables or disables diagnostics output from the scanner.
External Source Processing Mode Enables or disables processing of commands or data from sources external to the scanner. Command Command enables command processing in the scanner. Data Data enables EtherNet/IP as a data source port. Note: The data path between in the source port and out the source port is always two-way. Data is copied from source data ports and all those source ports’ data is transmitted to the destination port, and from the destination port to the source port. 5-20
FIS-0870 Industrial Raster Scanner User’s Manual