Page 42

Hardware Integration This section introduces the details of FIS-0870 hardware, and explains how that hardware can be integrated in an application.

FIS-0870 Industrial Raster Scanner User’s Manual

3-1

Page 43

Connectors

Connectors Industrial cabling and connectivity schemes must be able to withstand environmental extremes of heat, cold, and moisture, and be secure enough not to be disconnected or damaged inadvertently in the course of day-to-day operation. The current industry standard for connectivity is a sealed, circular connector such as the M12. The International Electrotechnical Commission (IEC) standard for M12 connectors describes them as fixed and free screw-locking connectors. This type of connector is widely available off-the-shelf from manufacturers such as Turck, Lumberg, Phoenix Contact, Molex, or Binder. The FIS-0870 uses sealed, circular connectors with Ultra-Lock™ technology. Ultra-Lock connectors are more resistant to harsh industrial conditions, and are easy to connect.

Ultra-Lock Connectors wenglor has adopted Ultra-Lock connectivity because of speed, ease-of-use, and ingress protection considerations. The main advantage of the Ultra-Lock system is that only two steps are required at every connection point: • Align the connector and receptacle keys; • Push the connector into place. (Do not twist the connector, as this can bend the pins.) Ultra-Lock connectors are “operator-independent”. This means that they are not subject to under-tightening or over-tightening, both of which are common problems with screw-down connectors, and both of which undermine the moisture-resistant seal.

Ultra-Lock Connector

Traditional Threaded Connectors

Another advantage of the FIS-0870’s Ultra-Lock connectivity scheme is that the Ultra-Lock receptacles on the scanners and the Interface Device also accept screw-down connectors, giving users the flexibility to use either Ultra-Lock or screw-down connectors.

“Ultra-Lock” is a trademark of Woodhead (Molex).

3-2

FIS-0870 Industrial Raster Scanner User’s Manual

Page 44

Hardware Installation

Cordsets The terms “cordset” and “cable” are both applicable to industrial connectivity, but they are not synonymous. Cordsets enable communications and power between scanners and interface devices. Cordsets have an M12 Ultra-Lock connector at one or both ends. Examples of cordsets are shown below.

M12 Ultra-Lock to M12 Ultra-Lock Cordset

M12 Ultra-Lock to RJ45 (Ethernet) Cordset

M12 Ultra-Lock to Photo Sensor Cordset

Cables do not have M12 Ultra-Lock connectors at either end. An example of a cable is shown below.

Cable with flying leads

FIS-0870 Industrial Raster Scanner User’s Manual

3-3

Page 45

FIS-0870 Connectors and Pinouts

FIS-0870 Connectors and Pinouts When deploying a network of scanners and interface devices in an industrial setting, it is important to use components whose pin assignments are arranged in a way that avoids communication errors and equipment damage. This can be achieved with components that are designed in a logical, consistent, and easy-to-implement way. The FIS-0870 has a very simple pin assignment methodology. The clearly identified connectors at the back of the unit can be used to receive and bus power, and also to send and receive data and commands. FIS-0870 (Base View) A is a serial M12 12-pin plug. B is a serial M12 12-pin socket or an Ethernet M12 8-pin socket.

B

A

P/M is a serial M12 12-pin plug.

P/M

T is a 4-pin Micro-Change socket (identical to the Interface Device trigger connector).

T

RS-422/485 RxD (–)

Output 2 Default

New Master

N/C Power

Output 1

RS-232 TxD

Output 3

Trigger Ground

N/C

Ground

N/C

RS-422/485 RxD (+)

Power

RS-422/485 TxD (+) N/C

N/C

RS-232 RxD

Input Common

N/C

RS-422/485 TxD (–)

Output Common

A (Serial) M12 12-pin Plug

P/M (Serial) M12 12-pin Plug

RS-422/485 RxD (–) Input Common

RS-232 TxD/ RS-232 RTS Trigger

Ground

RS-232 RxD/ RS-232 CTS

RS-422/485 RxD (+)

Power

RS-422/485 TxD (+)

RX (–)

Terminated Terminated

RX (+) Terminated

Input 1

Terminated

RS-422/485 TxD (–)

B (Serial) M12 12-pin Socket

3-4

TX (+)

TX (–) Terminated

B (Ethernet) M12 8-pin Socket

FIS-0870 Industrial Raster Scanner User’s Manual

Page 46

Hardware Installation

Grounding the FIS-0870 Proper grounding is necessary for operator safety, noise reduction, and the protection of equipment from voltage transients. Buildings, including any steelwork, all circuits, and all junction boxes must be grounded directly to an earth ground in compliance with local and national electrical codes.

An earth ground is provided through the cable shields and chassis of the scanner.

Ground Loops Ground loops (signal degradation due to different ground potentials in communicating devices) can be eliminated or minimized by ensuring that both the host, scanner, and their power supplies are connected to a common earth ground.

FIS-0870 Industrial Raster Scanner User’s Manual

3-5

Page 47

FIS-0870 Connectors and Pinouts

Expected Power and Ground Connections for Proper Operation

Notes: • Ensure that mounting bracket “Earth” is at the same potential as power source “Earth”. • Supply “Return” and “Earth” ground must be stable, low-impedance reference points. • “2-Terminal Power Supply” must still provide an “Earth” connection to the scanner. • “Signal Ground” can be used for communications and/or discrete signal ground reference. It must not be used as Power Ground or Earth Ground.

3-6

FIS-0870 Industrial Raster Scanner User’s Manual

Page 48

Hardware Installation

Interface Device The Interface Device’s receptacles are physically the same as those on the FIS-0870, but they do not have explicit pin assignments. The Interface Device allows users to bus power and communications as required by the application. Connectors 1 and 3 are 12-pin plugs, and Connector 2 is a 12-pin socket. All three connectors can be assigned to bus power and data as required by the application. The two switches at the center of the device allow the user to route signals as needed. 1, 3 1,3, T

PWR TRIG

1,2, 3 1,2, 3, T

Interface Device Pin 1 2 3 4

Assignment + 10-28V Trig/NM/Input 1 Common Ground Trigger

Interface Device Trigger Connector 4-pin Socket This simple diagram (shown on the base of the Interface Device) illustrates how power, communications, I/O, and trigger signal can be routed through the Interface Device device depending on the needs of the application. The switches greatly increase signal routing flexibility.

Communications - I/O Power - Trigger

FIS-0870 Industrial Raster Scanner User’s Manual

3-7

Page 49

Power and Trigger Switching

Power and Trigger Switching

1, 3 1,3, T

3-8

PWR TRIG

1,2, 3 1,2, 3, T

Power can be bussed between scanners and interface devices. At each location on a network where a new power supply is added, the Power switch on the Interface Device can be used to break power between Connector 2 and Connectors 1, 3, and T. The Trigger signal between Connector 2 and Connectors 1, 3, and T can be broken using the Trigger switch. This isolates trigger signals as required by the application.

FIS-0870 Industrial Raster Scanner User’s Manual

Page 50

Hardware Installation

Port Routing The physical advantages created by flexible signal routing and switching are enhanced further by Port Routing, which can be configured in ESP. Port Routing eliminates the need for dedicated “Host” and “Aux” ports in a traditional sense. With Port Routing, any port can be defined as a Host or Aux port. Port Routing also allows users to define the data types that are accessible from specific ports. The primary benefit of Port Routing is that any type of data can be routed to any port, and can be sent through multiple ports simultaneously. Multiple types of data can also be appended to the symbol data that is output from the scanner to the host. Command data, symbol data, extra symbol information, and diagnostic data are enabled by default in the FIS0870. The table below lists different types of data, with examples for each data type. Data Type

Example

Command Data

Serial commands; scanner responses to serial commands.

Symbol Data

Any string of data encoded in a symbol.

Extra Symbol Information

Decodes per trigger, decode direction, configuration database index number.

Diagnostic Data

Laser status, temperature, service message.

The screen capture below (from ESP) shows the FIS-0870’s four communications ports and the parameters for each.

RS-232 A, RS-232 B, and RS-422 are serial. RS-232 A is always enabled. RS-232 B and RS-422 can be enabled or disabled to match the physical requirements of the application. Ethernet can also be enabled or disabled as required. RS-232 A, RS-232 B, and RS-422 can be configured for Baud Rate, Parity, Stop Bits, Data Bits, Symbol Data Output, Extra Symbol Information (Decodes Before Output, Symbol Position Output, etc.), Diagnostics Output, and External Source Processing Mode (Command or Data). Ethernet can be configured for IP Address, Subnet Mask, Gateway, IP Address Mode (Primary or Secondary TCP Port), Symbol Data Output, Extra Symbol Information, Diagnostics Output, and External Source Processing Mode.

FIS-0870 Industrial Raster Scanner User’s Manual

3-9

Page 51

Application Examples

Application Examples The following examples demonstrate how the components described in previous sections can be deployed in industrial applications. Daisy Chain Daisy chain configurations are used in applications such as product packaging, where single items have multiple symbols. For example, a box with one symbol on the top and symbols on either side requires at least three scanners to ensure that all symbols will be decoded. The highlighted areas below demonstrate how a daisy chain can be arranged. One scanner is placed above the conveyor line and one scanner is placed on each side of the line. The three scanners essentially function as a single scanner, and data is sent from the primary scanner to the host or PLC.

3-10

FIS-0870 Industrial Raster Scanner User’s Manual

Page 52

Hardware Installation Multidrop Multidrop networks are used in applications where it is necessary to decode symbols at multiple locations within an industrial process. Scanners are placed at stations located between manufacturing steps, and data from those scanners is directed to a multidrop concentrator before being sent to a host. An example of this type of application is food packaging, in which part number data is collected and tracked throughout the packaging process. The highlighted areas below demonstrate how a multidrop network can be arranged.

FIS-0870 Industrial Raster Scanner User’s Manual

3-11

Page 53

Application Examples Ethernet TCP/IP and EtherNet/IP Ethernet TCP/IP is the standard Ethernet interface used to connect multiple locations in a network, such as computers in an office network. It can also be used to network other communications devices, such as scanners and PLCs on a factory floor. EtherNet/IP™ is a protocol developed and governed by ODVA (Open DeviceNet Vendors Association). It is based on the Common Industrial Protocol (CIP™). The CIP layer is an additional layer within the standard Ethernet interface (Ethernet TCP/IP). EtherNet/IP is common in control systems and PLCs, especially in the United States. The highlighted areas below demonstrate how an Ethernet daisy chain can be arranged. Ethernet-enabled scanners can also be set up in standalone configurations, or multiple Ethernet-enabled scanners along a production or packaging line can be connected to Ethernet.

“EtherNet/IP” and “CIP” are trademarks of the Open DeviceNet Vendors Association.

3-12

FIS-0870 Industrial Raster Scanner User’s Manual