The text of a manual · part 33 of 42
FIS-0870 Industrial Sweep Raster Scanner User's Manual: Utilities, pages 288 to 297
Pages 288 to 297 of 381, from FIS-0870 Industrial Sweep Raster Scanner User's Manual
The original document is the PDF (4.9 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Wenglor FIS-0870
Page 288
General Specifications Mechanical Height: 4.59" (109 mm) Width: 3.74" (95 mm) Depth: 1.76" (45 mm) Weight: 16 oz. (453 g)
Environmental Enclosure: Die-cast aluminum, IP65 rated Operating Temperature: 0° to 50° C (32° to 122° F) Storage Temperature: –50° to 75° C (–63° to 167° F) Humidity: up to 90% (non-condensing)
Emissions Heavy Industrial: EN 61000-6-2:2005 Radiated Emissions: EN 55022:2006 Class A 30-1000 MHz Conducted Emissions: EN 55022:2006 Class A .15-30 MHz
Communication Interface Standard Interfaces: RS-232, RS-422, RS-485, Ethernet
Symbologies
FIS-0870 Dimensions
Standard Offering: Code 39, Codabar, Code 93, Interleaved 2 of 5, Code 128, PDF417, MicroPDF417, Pharmacode, UPC, GS1 DataBar Applications Standards: EAN-128, AIAG
Laser Light Type: Laser diode Output Wavelength: 655 nm nominal Operating Life: 50,000 hours @ 25° C Safety Class: Visible laser: CDRH Class II, 655 nm
Scanning Parameters Mirror Type: Rotating, 10-faceted Scan Rate: Adjustable from 300 to 1,400 scans per second Scan Width Angle: Typically 60° Pitch: ±50° max. Skew: ±40° max. Symbol Contrast: 25% min. absolute dark-to-light differential at 655 nm wavelength Raster Mirror Performance: 1° - 10°: 80 sweeps per second; 11° - 20°: 60 sweeps per second; 21° - 34° (max.): 40 sweeps per second; 35° - 36° (max.): 20 sweeps per second
Protocols Point-to-Point, Point-to-Point with RTS/CTS, Point-to-Point with XON/XOFF, Point-to-Point with RTS/CTS and XON/XOFF, Multidrop, Daisy Chain, User-Defined Multidrop, Ethernet TCP/IP, EtherNet/IP
Discrete I/O Input 1 (Trigger / New Master): Optoisolated, 4.5–28V rated (13 mA at 24VDC); New Master is (–) to signal ground Outputs (1, 2, 3): Optoisolated, 1–28V rated (ICE < 100 mA at 24VDC, current limited by user)
FIS-0870 Industrial Raster Scanner User’s Manual
A-1
Page 289
Interface Device Mechanical Height: .75" (19.1 mm) Width: 2.50" (83.5 mm) Depth: 3.15" (80 mm) Weight: 7 oz. (200 g)
Interface Device Dimensions
A-2
FIS-0870 Industrial Raster Scanner User’s Manual
Page 290
Appendices
Read Ranges
Low Density
Low Density
Medium Density
High Density
Medium Density
High Density
Narrow Bar Width
Read Range
.0075" (.191 mm)
10 to 12" (254 mm to 305 mm)
.010" (.254 mm)
7 to 16" (178 mm to 406 mm)
.015" (.381 mm)
6 to 19" (152 mm to 483 mm)
.020” (.508 mm)
5 to 22” (127 to 558 mm)
.040” (1.02 mm)
4 to 30” (102 to 762 mm)
.0075" (.191 mm)
10 to 12" (254 mm to 305 mm)
.010" (.254 mm)
7 to 16" (178 mm to 406 mm)
.015" (.381 mm)
6 to 19" (152 mm to 483 mm)
.020” (.508 mm)
5 to 22” (127 to 558 mm)
.030” (.762 mm)
1.0 to 12” (25 to 304 mm)
.0033” (.084 mm)
Call wenglor
.005” (.127 mm)
4 to 5.0” (102 to 127 mm)
.0075" (.191 mm)
10 to 12" (254 mm to 305 mm)
.010" (.254 mm)
7 to 16" (178 mm to 406 mm)
.015" (.381 mm)
6 to 19" (152 mm to 483 mm)
FIS-0870 Industrial Raster Scanner User’s Manual
A-3
Page 291
Electrical Specifications 9 Watts (max.), 10-28VDC, 200 mV p-p max. ripple, 270mA at 24VDC (typ.)
Power Requirement
FIS-0870 Connectors RS-422/485 RxD (–)
Output 2 Default
New Master
N/C Power
Output 1
RS-232 TxD
Output 3
Trigger Ground
N/C
Ground
N/C
RS-422/485 RxD (+)
Power
RS-422/485 TxD (+) N/C
N/C
RS-232 RxD
Input Common
N/C
RS-422/485 TxD (–)
Output Common
A (Serial) M12 12-pin Plug
P/M (Serial) M12 12-pin Plug
RS-422/485 RxD (–) Input Common
RS-232 TxD/ RS-232 RTS Trigger
Ground
RS-232 RxD/ RS-232 CTS
RS-422/485 RxD (+)
Power
RS-422/485 TxD (+)
RX (–)
Terminated Terminated
RX (+) Terminated
Input 1
Terminated
RS-422/485 TxD (–)
B (Serial) M12 12-pin Socket
A-4
TX (+)
TX (–) Terminated
B (Ethernet) M12 8-pin Socket
FIS-0870 Industrial Raster Scanner User’s Manual
Page 292
Appendices
Interface Device Connectors Connector T on the Interface Device is the Trigger connector. Connectors 1, 2, and 3 can be used to bus power and data as required by the application. The connectors on the Interface Device physically mirror those on the FIS-0870 scanner, but they do not have explicit pin assignments. The Interface Device connectors take on the communications and power roles that are assigned to them. Trigger
Ground
+10-28V
1 +10-28V 2 Trigger / New Master / Input 1 Common 3 Ground 4 Trigger
Trigger/New Master / Input 1 Common
Interface Device Trigger Connector 4-pin Socket
Power Switch Trigger Switch
Interface Device Wiring Diagram Connectors 1 and 3 are 12-pin plugs, and Connector 2 is a 12-pin schprocket. All three connectors can be assigned to bus power and data. The two switches at the center of the device allow the user to route signals as needed. The simple diagram above (also shown on the base of the Interface Device) illustrates how power, communications, I/O, and trigger signal can be routed through the Interface Device. Power can be bussed between scanners and interface devices. At each location on a network where a new power supply is added, the Power switch on the Interface Device can be used to break power between Connector 2 and Connectors 1, 3, and T. The Trigger signal between Connector 2 and Connectors 1, 3, and T can be broken
FIS-0870 Industrial Raster Scanner User’s Manual
A-5
Page 293
Ground and Shield Considerations Proper grounding is necessary for operator safety, noise reduction, and the protection of equipment from voltage transients. Buildings, including any steelwork, all circuits, and all junction boxes must be grounded directly to an earth ground in compliance with local and national electrical codes.
An earth ground is provided through the cable shields and chassis of the scanner.
Ground Loops Ground loops (signal degradation due to different ground potentials in communicating devices) can be eliminated or minimized by ensuring that both the host, scanner, and their power supplies are connected to a common earth ground.
A-6
FIS-0870 Industrial Raster Scanner User’s Manual
Page 294
Appendices
Expected Power and Ground Connections for Proper Operation
Notes: • Ensure that mounting bracket “Earth” is at the same potential as power source “Earth”. • Supply “Return” and “Earth” ground must be stable, low-impedance reference points. • “2-Terminal Power Supply” must still provide an “Earth” connection to the scanner. • “Signal Ground” can be used for communications and/or discrete signal ground reference. It must not be used as Power Ground or Earth Ground.
Mounting at vibrating Ground If you are mounting the scanner at vibrating ground, please ensure that the scanner is mounted free of vibrations. Vibrations can reduce the lifetime of the scanner.
FIS-0870 Industrial Raster Scanner User’s Manual
A-7
Page 295
Serial Commands Communication RS-232 A RS-232 B RS-422 Ethernet Ethernet TCP Ports EtherNet/IP RS-232 A Data Type RS-232 B Data Type RS-422 Data Type Ethernet TCP Port 1 Data Type Ethernet TCP Port 2 Data Type EtherNet/IP Data Type Preamble Postamble Response Timeout LRC Status ACK/NAK Options Polling Mode Options Autoconfiguration Daisy Chain Protocol Selection External Data Routing Array Communication Modes Read Cycle Trigger Mode / Trigger Filter Duration Serial Trigger Character External Trigger State End of Read Cycle Decodes Before Output Multisymbol Serial Trigger Start Character Serial Trigger Stop Character Processing Timeout Scan Speed
A-8
<K100,baud rate,parity,stop bits,data bits> <K101,status,baud rate,parity,stop bits,data bits> <K102,status,baud rate,parity,stop bits,data bits> <K126,status,IP address,subnet,gateway,IP address mode> <K127,TCP Port 1,TCP Port 2> <K129,status> <K130,symbol data output,extra symbol information,diagnostic output,external source processing mode> <K131,symbol data output,extra symbol information,diagnostic output,external source processing mode> <K132,symbol data output,extra symbol information,diagnostic output,external source processing mode> <K133,symbol data output,extra symbol information,diagnostic output,external source processing mode> <K134,symbol data output,extra symbol information,diagnostic output,external source processing mode> <K136,symbol data output,extra symbol information,diagnostic output,external source processing mode> <K141,status,preamble> <K142,status,postamble> <K143,response timeout> <K145,status> <K147,RES,REQ,STX,ETX,ACK,NAK> <K148,RES,REQ,STX,ETX,ACK,NAK> <K150DAISY> <K160,protocol,address,protocol port> <K161,mode,destination port,ambles to source,echo to source,output at end of read cycle,output at ETX,output at timeout> <K162,mode,source,daisy chain i.d. status,daisy chain i.d.> <K200,trigger mode,leading edge trigger filter duration,trailing edge trigger filter duration> <K201,serial trigger character> <K202,external trigger state> <K220,mode,read cycle timeout> <K221,mode,number before output> <K222,number of symbols,multisymbol separator> <K229,start character> <K230,stop character> <K245,processing timeout> <K500,scan speed> FIS-0870 Industrial Raster Scanner User’s Manual
Page 296
Appendices Maximum Element Automatic Gain Control Symbol Detect Status / Transition Counter Raster Framing Scan Width Enhance AGC Tracking Laser Setup Configuration Database Number of Active Indexes Configuration Database Switch Timing Symbologies Quiet Zone Background Color Symbol Ratios Composite AIAG Depth of Field Enhance Code 39 Codabar Interleaved 2 of 5 UPC/EAN Code 128 / EAN 128 Code 93 PDF417 Pharmacode DataBar Omnidirectional (RSS-14) DataBar Limited (RSS Limited) DataBar Expanded (RSS Expanded)
<K502,maximum element> <K504,gain level,AGC sampling mode,AGC minimum,AGC maximum> <K505,symbol detect status,transition counter> <K506,status,top offset,bottom offset,sweep rate,read cycle on/off> <K511,status> <K520,tracking> <K700,laser on/off,laser framing status,laser on position,laser off position,laser power> <K252,number of active indexes,number of database cycles> <K253,index,gain,AGC mode,tracking,raster top,raster bottom, raster speed,framing status,laser on position,laser off position, laser power,background color> <K254,switch mode,frame count/time> <K450,quiet zone status> <K451,background color> <K452,Code 39,Codabar,Interleaved 2 of 5> <K453,symbology status,separator status,separator> <K454,status,ID1,status1,ID2,status2,ID3,status3,ID4,status4, ID5a,ID5b,ID5c,status5, ID6,status6,ID7,status7,ID8, status8, ID9,status9,ID10,status10,ID11,status11,ID12,status12> <K456,DOF Enhance mode> <K470,status,check character status,check character output status, large intercharacter gap,fixed symbol length status,fixed symbol length,full ASCII set> <K471,status,start/stop match status,start/stop output status, large intercharacter gap,fixed symbol length status,fixed symbol length,check character type,check character output status> <K472,status,check character status,check character output status, symbol length 1,symbol length 2,guard bar,range mode status> <K473,mode,EAN status,supplementals status,separator status, separator character,supplementals type,UPC-E as UPC-A> <K474,status,fixed symbol length status,fixed symbol length, EAN status,output format,application record separator status, application record separator character,application record brackets, application record padding,separation factor> <K475,mode,fixed symbol length status,symbol length> <K476,status,raster sweep count,fixed symbol length status, fixed symbol length,unused,codeword collection> <K477,status,fixed bar count status,fixed bar count,minimum bar count,bar width mode,direction,fixed threshold value> <K482,status> <K483,status> <K484,status,fixed symbol length status,fixed symbol length>
FIS-0870 Industrial Raster Scanner User’s Manual
A-9
Page 297
Communication Protocol Commands MicroPDF417 Symbol Reconstruction
<K485,status,raster sweep count,fixed symbol length status, fixed symbol length> <K496,symbol reconstruction redundancy,symbol reconstruction effort>
I/O Parameters Calibration Options Serial Verification Beeper Quality Output Symbol Data Output Read Duration Output No Read Message Bad Symbol Message No Symbol Message Input 1 Green Flash LED Status Indicators Symbol Position Output Database Identifier Output EZ Button EZ Button Modes Auto Framing Options Trend Analysis Output 1 Trend Analysis Output 2 Trend Analysis Output 3 Diagnostics Output 1 Diagnostics Output 2 Diagnostics Output 3 Output 1 Parameters Output 2 Parameters Output 3 Parameters Matchcode Matchcode
A-10
<K521,raster framing,video,scan speed,laser power,laser framing, symbology> <K701,serial command echo status, serial command beep status, control/hex output> <K702,status> <K704,quality output separator, decodes per trigger status, decode direction output> <K705,symbol data output status, when to output symbol data, symbology identifier status> <K706,status,separator> <K714,status,message> <K715,status,message> <K716,status,message> <K730,input mode,active state> <K750,green flash mode,unused,green flash duration> <K751,status,bar graph,I/O 1,I/O 2> <K758,raster position output status,scan position output status, separator> <K759,status,separator character> <K770,status,default on power-on> <K771,single beep,two beeps,three beeps,four beeps> <K773,laser framing> <K780,trend analysis mode,number of triggers,number to output on,decodes per trigger> <K781,trend analysis mode,number of triggers,number to output on,decodes per trigger> <K782,trend analysis mode,number of triggers,number to output on,decodes per trigger> <K790,high temperature,service unit,unused,laser current high, laser current low,low temperature> <K791,high temperature,service unit,unused,laser current high, laser current low,low temperature> <K792,high temperature,service unit,unused,laser current high, laser current low,low temperature> <K810,output on,output state,pulse width,output mode> <K811,output on,output state,pulse width,output mode> <K812,output on,output state,pulse width,output mode> <K223,matchcode type,sequential matching,match start position, match length,wild card,sequence on no read,sequence on mismatch>
FIS-0870 Industrial Raster Scanner User’s Manual