Page 278

Utilities

Customer Default Parameters Customer default parameters (saved by <Zc>) are the same set of parameters as power-on parameters but are saved in a different, isolated section of NOVRAM. This allows a user essentially to create a back-up set of parameters that can be recalled in the event that the current parameters or power-on parameters have been accidentally changed or are no longer desired. It is important to note that a hardware default does not affect customer default parameters. For example, a user that has inadvertently changed communication settings and saved them with a <Z> command, may not know the correct settings or have the capability to communicate within those settings. By first doing an EZ Button default to restore the known wenglor defaults, the user can then recall the previous customer-saved settings with an <Arc> or <Zrc> command.

wenglor Default Parameters wenglor default parameters are contained in the firmware and cannot be changed.

Software Defaults wenglor default parameters can be recalled (loaded into current settings) with the <Ard> command or recalled and saved for power-on with the <Zrd> command.

Default on Power-On Use the EZ Button to default the scanner by holding it down while applying power to the scanner (if this feature is enabled).

FIS-0870 Industrial Raster Scanner User’s Manual

7-21

Page 279

Scanner Status Requests

Scanner Status Requests <K?> All Status Request This is the fastest way to learn the scanner’s current configuration. Sending this request will return the current settings of all commands, starting with the lowest K command value and ending with the highest K command value.

<K??> All Descriptor Status Request This request will return all current descriptors for every K command, starting with the lowest K command value and ending with the highest K command value.

<K?#> All Range Status Request This request will return the current settings of all commands within the user-defined range, starting with the lowest user-defined K command value and ending with the highest user-defined K command value.

<Knnn?> Single Status Request This request will return the value of the variables associated with the requested K command. The request of a single entry of a database command cannot exceed the number of database slots for the specific command.

<Knnn??> Single Descriptor Status Request This request returns the basic functional description of all fields in the requested K command.

<Knnn?#> Single Range Status Request This request will return the value range and storage type description of all fields in the requested K command.

<Knnnd> Default Customer Parameter This request will default a single K command if the command has customer-defined parameters rather than factory-defined parameters.

7-22

FIS-0870 Industrial Raster Scanner User’s Manual

Page 280

Utilities

Other Serial Utility Commands Calibration without Menu Sending the <@CAL> command from ESP’s Terminal initiates auto-calibration without entering the auto-calibration menu. The calibrated parameters are determined by the settings of the Calibration Options command.

Calibration with Menu Sending the <@> command from ESP’s Terminal enters the auto-calibration menu. The initial state of the menu is determined by the settings of the Calibration Options command.

When the Auto Calibration menu is entered, or when calibration is beginning, all NOVRAM settings that will be calibrated, manipulated during the calibration process, or configured by the calibration menu are saved to an “initial” settings buffer: • AGC Mode • Gain • Tracking • Motor Speed • Laser On Position • Laser Off Position • Laser Framing Status • Laser Power • Laser On/Off Status • Raster Top Offset • Raster Bottom Offset • Raster Status • Raster On/Off Status Note: Calibration Options and symbology status are not backed up. Any changes made to Calibration Options, or any new symbologies detected, can only be restored by cycling power or sending a “Recall” command: <Arp>, <Arc>, <Zrd>, or <Zrc>. FIS-0870 Industrial Raster Scanner User’s Manual

7-23

Page 281

Other Serial Utility Commands

Calibration Progress Indicators The calibration process occurs in five phases: Quick Focus, Search Pass, Focus Pass, Medium Pass, and Fine-Tune Pass. The scanner quickly locates the configuration setup, defines a calibration range for the parameters, and then tunes the parameters for optimal performance. During the calibration process, the scanner has a number of ways to communicate its progress to the user. The following three types of feedback are the primary ways that the scanner communicates calibration progress. LEDs 20% 20%, 40% 20%, 40%, 60% 20%, 40%, 60%, 80% 20%, 40%, 60%, 80%, 100%

Calibration Progress Search Pass in progress Locate Center Focus in progress Medium Pass in progress Fine-Tune Pass in progress Calibrated Successfully (holds for green flash duration)

Beeper/Green Flash The beeper and green LED flash are used to indicate calibration status as shown in the table below: Indicator 2 quick beeps 5 quick beeps 1 long beep 1 sec. Green Flash

7-24

Status Calibration has started Calibration has failed Calibration has been completed successfully Calibration has been completed successfully

FIS-0870 Industrial Raster Scanner User’s Manual

Page 282

Utilities

Outline of Full Auto Calibration Process Auto Calibration runs a calibration cycle for the scanner to optimize basic symbol decoding parameters. Focus, Gain, Shutter Speed, and Symbol Type are all configured during Auto Calibration. To configure the operation of Auto Calibration see Calibration Options. The calibration cycle can be entered either through ESP, serial command, or the EZ Button. • If laser framing is enabled, set scan line to full. • If laser power calibration is enabled, set laser power to factory default. • If motor speed calibration is enabled, set motor speed to factory default. • If video calibration is enabled, set gain and tracking to default. • If symbology detection is enabled: initialize symbology detection array with current symbology status configuration; enable all symbologies (except PDF417 and Pharmacode); symbology detection continues to operate concurrently with all remaining calibration processes. • Set LEDs to display 20% LED on, all others off. • Pre-position the raster: As-Is: no change; Straight: set raster straight out; Search or Frame: sweep the raster through full sweep angle. If a symbol is found, place raster in the middle of the symbol. If no symbol is found, set raster straight out. • Set LEDs to display 40% LED on, all others off. • Perform one pass of symbology detection (100 scans are decoded). • Perform motor and laser calibration (if enabled). • If motor speed calibration is enabled, motor speed starts at 300 sps, and is increased by 50 sps until 500 sps. After 500 sps, motor speed is increased by 100 sps until 1,000 sps. Motor speed calibration is limited to a maximum of 1000 sps, or motor speed is not changed. • If laser power calibration is enabled, at each motor speed increment, laser power is cycled between low, medium, and high power settings, or laser power is not changed. • If video calibration is enabled, and AGC is enabled (not in Fixed Gain operation), several gain and tracking pairs are used at each motor speed and laser power combination, or video settings are unchanged. • A “best-ever” read rate value is initialized to 0 to start the calibration process. • At each motor speed/laser power/video combination, a new read rate is acquired. The settings used to acquire the new read rate are recorded as the new “best” if: The new read rate is better than 95%. Go to the next motor speed; The new read rate is greater than the best read rate. Go to the next laser power; The new read rate is equal to the best read rate, and the motor speed is greater. Go to the next laser power; The new read rate is equal to the best read rate, and the laser power is less. Go to the next laser power. • Set LEDs to display 60% LED on, all others off. • Restore user-configured video (gain and tracking) settings. • Perform video calibration, (if enabled): take initial read rate at current settings; calibrate video, select new gain and tracking; take final read rate with new gain and tracking; if FIS-0870 Industrial Raster Scanner User’s Manual

7-25

Page 283

Other Serial Utility Commands final read rate is < 2%, video calibration fails; if final read rate is > or = initial read rate, video calibration passes and new settings take effect; if final read rate is < initial read rate, video settings revert to pre-calibration values (this is not considered a “failure”; all other settings calibrated by other calibration processes like motor speed and laser power). • Perform raster framing if the raster parameter of the calibration command is set to “Frame”. • Perform laser framing, if enabled. • If symbology detection is enabled, update user NOVRAM with any new symbologies detected during calibration. Notes: If any step in the calibration process fails, of if the user cancels calibration, the remainder of calibration is canceled and all settings are restored to their previous state. This does not apply to symbology status when symbology detection is enabled. Any symbols that are decoded during calibration will be enabled, even if any other calibration processes fail or are canceled.

7-26

FIS-0870 Industrial Raster Scanner User’s Manual

Page 284

Utilities

Bar Code Configuration Mode Bar Code Configuration Mode is a way of programming the scanner by using symbols. Bar Code Configuration Mode can be entered two different ways: • By forcing the scanner into Bar Code Configuration Mode by serial command <BCCFG>. • By configuring one of the four EZ Button positions (Single Beep, Two Beeps, Three Beeps, Four Beeps) to Bar Code Configuration Mode. Once Bar Code Configuration Mode has been entered, symbols can be thought of as serial data. Configure the scanner by printing symbols in wenglor’s serial command format. Commands are processed as if the data were streamed in through the serial port. The scanner will acknowledge the symbol with a beep, green flash, and echo the serial data to the host. If the command causes the scanner to produce more serial output, such as serial verification or counter requests, the data will be routed to the host. Bar Code Configuration Mode can be exited by any reset <A> or <Z> command as well as a <J> or a quick press and release of the EZ Button. The command to exit Bar Code Configuration Mode can be included as part of the symbol. For example, try encoding <K200,4><K220,1><J> into a symbol. This configures the scanner to enable Serial Trigger Mode, to program a new trigger to end the read cycle, and to exit Bar Code Configuration Mode with <J>. To end all EZ Button functions, press the EZ Button once and quickly release.

FIS-0870 Industrial Raster Scanner User’s Manual

7-27

Page 285

Embedded Menus

Embedded Menus The FIS-0870 contains Embedded Menus to provide easy configuration in situations where a ESP Software may not be available or applicable. The Embedded Menus consist of a Main Menu and a sub-menu for every group of commands. The following example shows how a user can operate the FIS-0870’s Embedded Menus.

Main Menu For the purpose of this example, assume the user wants to navigate to the Symbologies menu. The user would select C from the list. =========================[MAIN MENU]============================ A) COMMUNICATION B) SCANNER SETUP C) SYMBOLOGIES D) SCANNER I/O SETUP E) DIAGNOSTICS SETUP F) CONFIG IP DATABASE G) OUTPUT ORDER FILTER H) MATCHCODE -- PLEASE PRESS A-H TO EDIT, ESC TO EXIT |

Command Menu The user then selects B to navigate to the Code 128 menu. =======================[SYMBOLOGIES]============================ ---- Code Type --------------------- Status ---------A) CODE 39 ENABLE B) CODE 128 DISABLE C) CODE I 2 OF 5 DISABLE D) CODABAR DISABLE E) UPC DISABLE F) CODE 93 DISABLE G) PHARMA CODE DISABLE H) PDF417 DISABLE ------------- Global Parameters ------------I) Quiet Zone Status = DISABLE J) Symbology Identifier Status = DISABLE K) Background Color = White -- PLEASE PRESS A-K TO EDIT, 1=MAIN MENU, 2=PREVIOUS MENU, ESC TO EXIT

7-28

|

FIS-0870 Industrial Raster Scanner User’s Manual

Page 286

Utilities

Parameter Menu The user then selects B to configure the Fixed Symbol Length Status parameter. ===========================[CODE 128]============================ A) Code 128 Status = DISABLE B) Fixed Symbol Length Status = DISABLE C) Symbol Length = 10 D) EAN-128 Status = DISABLE E) Output Format = Standard F) Application Record Separator Status = DISABLE G) Application Record Separator Character = , H) Application Record Brackets = DISABLE I) Application Record Padding = DISABLE -- PLEASE PRESS A-I TO EDIT, 1=MAIN MENU, 2=PREVIOUS MENU, ESC TO EXIT

|

Parameter Options Menu At this level, the current setting and system default are both shown. The user can select the desired option and go back to the previous menu, or press Enter or ESC to return to the previous menu without any change to the parameter. ==================[Fixed Symbol Length Status]=================== A) DISABLE [CURRENT] [DEFAULT] B) ENABLE -- PLEASE PRESS A-B TO CHANGE THE PARAMENTER, ESC TO CANCEL |

Another example of a Parameter Options-level menu is the Symbol Length, shown below. In this menu, the user is prompted to enter a desired value in a range from 1 to 128, and the menu shows a system default of 10. After a desired value has been entered, the user must press Enter to confirm that the value is valid and return to the previous menu, or press ESC to return to the previous menu without any change to the parameter. The user could also return to the previous menu by pressing Enter when no value has been entered. =======================[Symbol Length]=========================== A) Symbol Length = 10 Rang: 1 - 128 System Default: 10 -- PLEASE TYPE THE NEW VALUE, THEN ENTER, ESC TO CANCEL -- NEW VALUE = |

FIS-0870 Industrial Raster Scanner User’s Manual

7-29

Page 287

Embedded Menus

7-30

FIS-0870 Industrial Raster Scanner User’s Manual