Page 268

Utilities

Master Symbol Database Size Master Symbol Database Size allows the user to select 1 to 10 master symbols for the master symbol database.

Set Master Symbol Database Size here.

Important: Since the total number of characters available for the master symbol database is 3000, changes to the Master Symbol Database Size will re-allocate the number of characters available for each master symbol and could cause existing master symbols to be deleted (except master symbol #1, unless it also exceeds the size limitation). The table below specifies the maximum number of characters available to each symbol according the number of master symbols defined, from 1 to 10. Master Symbol Number #1 #2 #3 #4 #5 #6 #7 #8 #9 # 10

Maximum Characters 3000 1500 1000 750 600 500 428 375 333 300

FIS-0870 Industrial Raster Scanner User’s Manual

7-11

Page 269

Master Database

Enter Master Symbol Data Allows the user to enter master symbol data for any enabled master symbol index number (1 to 10), provided the total number of characters does not exceed the maximum allowed. Enter data for 1 to 10 master symbols. Caution: If no data is entered, the existing data will be deleted. • Open the Utilities menu. • Set the number of master symbols to be created in Master Symbol Database Size. • Double-click on each master symbol number in the table, type master symbol data in the popup dialog that appears, and click OK. • When all master symbol data has been entered, click the Send Database to the Reader button.

Enter master symbol data in this field.

7-12

FIS-0870 Industrial Raster Scanner User’s Manual

Page 270

Utilities

Request Master Symbol Data Returns master symbol data for any enabled master symbols from 1 to 10. • Click the Utilities button and the Master Database tab. • Click the Receive Reader’s Database button.

Read Next Symbol as Master Symbol After the size of the database is set, the scanner can read the next symbol as the master symbol for any given master symbol number. <Gmaster symbol number> To store the next symbol decoded as master symbol # 1, send: <G> or <G1>. To store the next symbol decoded as the master symbol for any other master symbol database number, send: <Gmaster symbol number [1-10]>. For example, <G5> will cause the next symbol read to be entered as master symbol # 5. In the Master Database tab, • Select the master symbol index number in which new symbol data will be stored. • Click the Read Symbol into Selected Index button.

Caution: If an index with existing data is selected, that data will be overwritten by the new decoded data when this command is used.

FIS-0870 Industrial Raster Scanner User’s Manual

7-13

Page 271

Master Database

Request New Master Status Informs the user when a new master symbol is pending and which position it is in. Returns the position in the master symbol database that will be loaded on the next read. Send the <NEWM> command from ESP’s Terminal. The scanner returns: <NEWM/next master to load> Once a symbol has been read and loaded, the status will be cleared and the response will be <NEWM/0>.

7-14

FIS-0870 Industrial Raster Scanner User’s Manual

Page 272

Utilities

Delete Master Symbol Data Master symbol data can be deleted using ESP. • Click the Utilities button to access the master symbol. • Click the Master Database tab and double-click the symbol number to be deleted. • Delete text and click OK.

FIS-0870 Industrial Raster Scanner User’s Manual

7-15

Page 273

Digital Bar Code

Digital Bar Code Click the Utilities button and then the Digital Bar Code tab to display the Digital Bar Code view. Click the Digital Bar Code tab and the Start button to view a digitized representation of the symbol in front of the scanner.

This routine is useful for conveying a sense of the symbol’s readability and graphically indicating bad or unreadable portions of symbols or extraneous “noise”. A green waveform indicates a decoded symbol; a red waveform indicates an undecoded symbol or other object. The red triangles represent the width of the scan beam relative to the symbol. The upward pointing arrows indicate the symbol’s quiet zone.

Zoom In / Zoom Out Increase the zoom level by sliding the Zoom lever to the right. It may be necessary to scroll right or left to view the symbol’s waveform in its entirety.

7-16

FIS-0870 Industrial Raster Scanner User’s Manual

Page 274

Utilities

Firmware Click the Utilities button and then the Firmware tab to display the Firmware view.

Firmware Update Firmware Update is used to download application code to the scanner. Application code versions are specific to the scanner. Consult with a sales representative before downloading application code. If needed, application/boot code in the form of a *.mot file can be requested. To download application code: • First, be sure that the scanner is connected to the host computer. • Apply power to the scanner. • In the Firmware Update dropdown menu, select App Code. This will open a dialog that allows the user to browse for the application code file. • Navigate to where the application code file (a *.mot file) is located on the host computer. • Allow approximately a minute for firmware to download. As the application code begins to download, the scanner will be silent, the LEDs will flash intermittently, and a progress indicator at the bottom of the ESP window will show when the download is complete. Caution: Do not interrupt power or disconnect the host cable while download is in progress.

FIS-0870 Industrial Raster Scanner User’s Manual

7-17

Page 275

Firmware

Firmware Verification Request Part Number Send a request to the scanner for application code, boot code, or FPGA code part numbers. • Click the Firmware tab. • Select App Code, Boot Code, or FPGA Code from the dropdown menu to the left of the Request Part No. button. • Click the Request Part No. button to see the part number displayed in the text field to the right.

Request Part Number by Serial Command • When <#> (a request for all product part numbers) is sent, the scanner returns: <#b/BOOT_P/N><#a/APP_P/N><#p/PROFILE_P/N>. • When <#a> (a request for the application code part number) is sent, the scanner returns: <#a/APP_P/N>. • When <#b> (a request for the boot code part number) is sent, the scanner returns: <#b/BOOT_P/N>. • When <#f> (a request for the FPGA code part number) is sent, the scanner returns: <#f/FPGA_P/N>.

7-18

FIS-0870 Industrial Raster Scanner User’s Manual

Page 276

Utilities

Request Checksum Send a request to the scanner for application code, boot code, or FPGA code checksums. • Click the Firmware tab. • Select App Code, Boot Code, or FPGA Code from the dropdown menu to the left of the Request Checksum button. • Click the Request Checksum button to see the part number displayed in the text field to the right.

Request Checksum by Serial Command • When <!> (a request for all available firmware checksums) is sent, the scanner returns: <!b/BOOT_CHECKSUM><!a/APP_CHECKSUM><!p/PROFILE_CHECKSUM> • When <!a> (a request for the application code checksum) is sent, the scanner returns: <!a/APP_CHECKSUM> • When <!b> (a request for the boot code checksum) is sent, the scanner returns: <!b/BOOT_CHECKSUM> • When <!f> (a request for the FPGA code checksum) is sent, the scanner returns: <!f/FPGA_CHECKSUM>

FIS-0870 Industrial Raster Scanner User’s Manual

7-19

Page 277

Default / Reset / Save

Default / Reset / Save

Saved for Power-on

Resets (not saved for power-on)

Understanding and controlling the scanner’s active, saved, and default settings is critical to its successful operation. Function

Serial Cmd

Reset (Will not save for power-on)

<A>

Reset and Recall Power-On Parameters Reset and Recall Customer Default Parameters Reset and Recall wenglor Default Parameters

<Arp>

Save to Reader, Send No Save Send <Arp> from Terminal

<Arc>

Send <Arc> from Terminal

No

<Ard>

Send <Ard> from Terminal

No

ESPa

Save to Reader, Send and Save Save to Reader, Send and Save Customer Defaults for Power-Onb

EZ Button No No

Save Current Settings for Power-On

<Z>

Save Current Settings as Customer Default Parameters for Power-On

<Zc>

Recall Customer Default Settings and Save for Power-On

<Zrc>

Send <Zrc> from Terminal

Press and hold while powering on scanner

<Zrd>

Send <Zrd> from Terminal

No

<Zrdall>

Send <Zrdall> from Terminal

No

Recall wenglor Default Settings and Save for Power-On (Will not default “sticky settings”) Recall wenglor Default Settings and Save for Power-On (Will also default “sticky settings”)

No No a. When right-clicking in a tree control to select Default Current Menu Settings or Default All ESP Settings, it is important to note that only ESP settings are defaulted. To save these defaults to the scanner itself, follow up with a Save to Reader, Send and Save command. b. Only available in ESP if enabled in Preferences (General tab), accessible from the Options dropdown menu.

Resets Resets (“A” commands) affect only the current settings (active memory) and are not saved for power-on.

Saved for Power-on Power-on parameters (“Z” commands) are saved to NOVRAM and recalled and loaded into current parameters when power is cycled to the scanner or the <Arp> command is issued.

Defaults Defaults are wenglor firmware settings or saved customer settings that can be recalled, either by software or hardware reset.

7-20

FIS-0870 Industrial Raster Scanner User’s Manual