Page 258
Utilities This section explains the function and purpose of serial utility commands, which are generally performed during scanner operation.
FIS-0870 Industrial Raster Scanner User’s Manual
7-1
Page 259
Serial Utility Commands
Serial Utility Commands Note: For a list of all K commands, see Serial Commands. Type Read Rate
Counters
Device Control
Master Database
Part Number / Checksum
Command <C> <Cp> <J> <a1> <N> <O> <T> <U> <V> <W> <X> <Y> <L1> <L2> <L3> <I> <H> <G> <Gn> <NEWM> <#> <#a> <#b> <#f> <!> <!a> <!b> <!f> <Z> <Zc>
Default/Reset/Save
<Zrc> <Zrd>
7-2
Name Enter Decodes/Second Test Enter Decode Percent Test Exit Decodes/Second and Decode Percent Tests PDF417 Information No Read Counter No Read Counter Reset Trigger Counter Trigger Counter Reset Good Read/Match Counter Good Read/Match Counter Reset Mismatch Counter Mismatch Counter Reset Programmable Output 1 Programmable Output 2 Programmable Output 3 Disable Scanner Enable Scanner Store Next Symbol Read to Database Index 1 Store Next Symbol Read to Database Index n New Master Load Status Display All Firmware Part Numbers Display Application Code Part Number Display Boot Code Part Number Display FPGA Code Part Number Display All Available Firmware Checksums Display Application Code Code Checksum Display Boot Code Checksum Display FPGA Code Checksum Save Current Settings for Power-On Save Current Settings as Customer Default Parameters for Power-On Recall Customer Default Settings and Save for Power-On Recall wenglor Default Settings and Save for Power-On (Will not default “sticky settings”)
FIS-0870 Industrial Raster Scanner User’s Manual
Page 260
Utilities <Zrdall> Default/Reset/Save
Scanner Status Request Commands
Other Serial Utility Commands
<A> <Arp> <Arc> <Ard> <K?> <K??> <K?#> <Knnn?> <Knnn??> <Knnn?#> <Knnnd> <@CAL> <@> <BCCFG>
FIS-0870 Industrial Raster Scanner User’s Manual
Recall wenglor Default Settings and Save for Power-On (Will also default “sticky settings”) Reset (Will not save for power-on) Reset and Recall Power-On Parameters Reset and Recall Customer Default Parameters Reset and Recall wenglor Default Parameters All Status Request All Descriptor Status Request All Range Status Request Single Status Request Single Descriptor Status Request Single Range Status Request Default Customer Parameter Calibrate without Menu Calibrate with Menu Enter Bar Code Configuration
7-3
Page 261
Read Rate
Read Rate Click the Utilities button and then the Read Rate tab to display the Read Rate view.
To see the number of decodes per second, click the Decodes/sec radio button and then the Start button. To see the percentage of decodes, click the Percent radio button and then the Start button. Read Rate information is displayed in the lower portion of the Utilities view. Serial commands can also be sent to the scanner from this screen.
To end a Read Rate test, click the Stop button (the Start button becomes a Stop button during an active Read Rate test.)
Important: When Read Rate is enabled, the Configuration Database is not active, regardless of how the scanner is configured.
7-4
FIS-0870 Industrial Raster Scanner User’s Manual
Page 262
Utilities
Read Rate Serial Utility Commands Enter Decodes / Second Test Sending <C> instructs the scanner to transmit the decodes per second and symbol data (if any). The decode rate can vary dramatically due to the angle and location of the symbol in relation to the field of view. This test is very useful in aligning and positioning the scanner during setup.
Enter Decode Percent Test Sending <Cp> instructs the scanner to transmit the percentage of decodes and any decoded symbol data.
End Decodes / Second and Decode Percent Tests Sending <J> ends both the Percent test and the Decodes/Second test.
PDF417 Information Sending <a1> causes PDF417 data that is decoded in a triggered read cycle to be prefaced with information about the symbol’s level of error correction (error correction level n), number of rows (n rows), number of columns (n columns), number of informative code words (n code words), and number of data bits (n data bits). This feature can be disabled by sending <a1> again.
FIS-0870 Industrial Raster Scanner User’s Manual
7-5
Page 263
Counters
Counters Click the Utilities button and then the Counters tab to display the Counters view. Counter commands can be a numeric value from 00000 to 65535. After reaching the maximum numeric limit of 65535, an error message will be displayed and the counter will automatically roll over and start counting again at 00000. To obtain the cumulative total of counts after the rollover has occurred, add 65536 per each rollover (the scanner does not keep track of the number of rollovers) to the current count. Note: All counter values will be lost if power is recycled to the scanner, or if the scanner receives a Reset or Save command. Click the Request button to display the appropriate count or Clear to set the counter to zero.
Trigger, Good Read, No Read, and Mismatch counters can be requested and cleared simultaneously (Request All and Clear All buttons) or individually (Request and Clear buttons to the left of each item).
7-6
FIS-0870 Industrial Raster Scanner User’s Manual
Page 264
Utilities
Counters Serial Utility Commands No Read Counter Sending <N> displays the total number of No Reads that have occurred since the last reset.
No Read Counter Reset Sending <O> sets the No Read Counter to 00000.
Trigger Counter Sending <T> displays the total number of triggers since the last reset.
Trigger Counter Reset Sending <U> sets the trigger counter to 00000.
Good Read / Match Counter (or Good Read Counter) Sending <V> displays the total number of good reads matching the master symbol, or, if Master Symbol is not enabled, the number of good reads since the last reset. This counter is always enabled, but will only work as a match count when Master Symbol is enabled. If Master Symbol is not enabled, this counter records the number of good reads. This count can be requested at any time.
Good Read / Match Counter Reset Sending <W> sets the Match Counter to 00000.
Mismatch Counter Sending <X> displays the number of decoded symbols since the last reset that do not match the master symbol.
Mismatch Counter Reset Sending <Y> sets the Mismatch Counter to zero.
FIS-0870 Industrial Raster Scanner User’s Manual
7-7
Page 265
Device Control
Device Control Click the Utilities button and then the Device Control tab to display the Device Control view.
The Output 1 Pulse, Output 2 Pulse, and Output 3 Pulse buttons activate the link between the + and – of the host connector. The buttons in the Extras section can Disable or Enable the reader, or deactivate and reactivate the motor.
Device Control Serial Utility Commands Output 1 Pulse Sending <L1> activates the link between Output 1 (+) and Output 1 (–) of the host connector (regardless of Master Symbol or Output 1 status).
Output 2 Pulse Sending <L2> activates the link between Output 2 (+) and Output 2 (–) of the host connector (regardless of Master Symbol or Output 2 status).
Output 3 Pulse Sending <L3> activates the link between Output 3 (+) and Output 3 (–) of the host connector (regardless of Master Symbol or Output 3 status).
Disable Reader Sending <I> will turn the scanner OFF, end the current read cycle, and will not allow the scanner to enter another read cycle until turned ON. This feature is useful during extended periods of time when no symbols are being decoded, or the scanner is being configured. Disabling the scanner will not affect any commands that have already been downloaded.
Enable Reader Sending <H> will turn the scanner ON and allow it to enter read cycles.
7-8
FIS-0870 Industrial Raster Scanner User’s Manual
Page 266
Utilities
Differences from Default Click the Utilities button and then the Differences tab to display the Differences from Default view. Clicking the Differences from Default button will cause ESP to check all stored configuration settings and compare them to default settings. All settings that are different than default will appear in the left column (shown below), and descriptions of those settings will appear in the right column. Click this button for a list of ESP configuration settings that are different than default settings.
Click Generate Barcode to display the Bar Code Dialog. Then create configuration symbols containing the required configuration commands.
Send configuration settings to the scanner without saving by clicking Send to Reader.
Click Save As to save the report as plain text or a tab-delimited text file.
Send configuration settings to the scanner and save in ESP by clicking Send and Save.
• To create a symbol containing any of the command settings in the table, click Generate Barcode. • To save the Differences from Default report, either as plain text or as a tab-delimited text file, click Save As. • Click Send and Save to send the settings to the scanner and save them, or Send to Reader to send the settings without saving them. Important: To use Differences from Default, connect to the scanner and Receive Reader Settings via the Send/Recv button on the toolbar. FIS-0870 Industrial Raster Scanner User’s Manual
7-9
Page 267
Master Database
Master Database Click the Utilities button and then the Master Database tab to display the Master Database view. Important: The Master Database is used for all Matchcode modes except Sequential and Wild Card, both of which use Master Database Index # 1.
Master Database Overview Used where more than one master symbol is required, as in a Multisymbol setup, for matching and other Matchcode operations. Allows the user to define up to 10 master symbols as the master symbol database, which can be entered by keyboard, scanned in, displayed, or deleted by serial or ESP commands. • Click the Master Database tab. • Enable Matchcode Type. • Set the Master Symbol Database Size. • Select the database index in which the master symbol will be entered. • Do one of the following to enter master symbol data: Double-click the index row to type data directly into the index; Click the Read Symbol into Selected Index to enter the next decoded symbol. Set Master Symbol Database Size here.
Loads the next symbol decoded into the selected index.
Saves the database to the scanner. Loads the scanner’s saved master symbols into ESP.
Double-click a row to enter data into popup text box.
7-10
FIS-0870 Industrial Raster Scanner User’s Manual