Page 51
• When selecting regions, approximately square regions are created as 2D regions, and rectangular regions are created as 1D regions. If a 1D region is created when previous regions were 2D, then the newly created region will be put into a new group, and vice versa. • Once the settings for all groups have been established, the global settings can be set. These settings can be accessed by selecting “Options->Settings”. • The global settings are used for record keeping and reporting purposes. It is in these settings that user information can be set and digital copies of the reports can be saved. For more information on the use of these settings, please see the user guide, available in the Webscan Inc. folder in the start menu.
• Now that all regions have been selected and settings have been set, the symbols can be verified. To do this, press the button that reads “Verify Code”. Note that this is the same button that read “Go Live” before. • The verification process will proceed to verify each region, according to that region’s settings. This may take a moment. To help the verification process complete quickly, make sure that all regions contain a symbol.
• Once verification has completed, there are several tools available to help to analyze the results of the verification process. • First of all, each region will no longer be colored according to its group affiliation, but rather according to grade of the verified symbol within. Regions will be green if the grade is either an “A” or a “B”, yellow if the grade is a “C”, or red if the grade is “D” or “F”. • It is important to note that the region will be red if no symbol is decoded. “NO DECODE” is treated as an “F” grade for reporting purposes. • To view a quick overview of the performance of the decoded symbols, there is a chart in the lower right hand corner labeled “Verification Summary”. This chart will show the relative frequency of the three grade categories (green, yellow, red) as described above. • To access a printable summary report, click on the tab near the top left of the screen labeled
Page 52
“Summary”. This is a printer friendly report that summarizes the results of the verification. The report will begin with some information about the results of all regions combined, indicating the number of each grade received, then a small subsection for each region, including basic information for each symbol. • For a more thorough report, click on the tab labeled “Report” near the upper left. This will include a detailed report for every region, including information about the symbol’s overall grade and all other information that was selected in the settings menu. • Like the summary report, these reports are also printer friendly. To print the report, right click on the report, and select “Print Report”. • These detailed reports are an ideal way to keep and maintain a record of verification results, as they will contain all information relating to acceptance criteria, as well as a date and time to establish when the verification was completed. Note that what information is reported here is controlled by both the settings for the region and the global settings. • Results can also be reviewed on screen, and can be accessed either by double clicking on a region or by double clicking on the row of the “Summary Results” table on the upper right. This will create a popup window with detailed information about the symbol that was decoded. • There are several tabs and buttons available in this window, and they function exactly as they do in “Single Mode”. For information on what information is presented in these tabs, please see the user guide, available in the Webscan Inc. folder in the start menu.
• Once the results have been reviewed, and all desired reports have been printed, press “Go Live” to return to the state where new symbols can be presented, and the selected regions can again be modified.
Page 53
This section contains essential information to properly install, operate and maintain your Webscan TruCheck™ Laser USB Barcode Verifier.
The Webscan TruCheck™ Barcode Verifier complies with standard 21CFR1040.10. Caution - use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous laser light exposure. The type and location of warning labels that comply with the CDRH standard are illustrated below: The label below indicates the location of the aperture through which laser light is emitted.
AVOID EXPOSURE - Laser light is emitted from this aperture
The label below is located on the bottom of the unit and indicates the Model Number and Date of Manufacture: Model#
Manufactured
Serial#
Webscan, Inc. 1341 Sherman Dr. Unit D Longmont, CO 80501
The label below indicates that this product is a Class II laser device and contains the FDA Class II Warning logotype:
Page 54
The label below contains the FCC Compliance Statement, the CDRH Compliance Statement and the caution statement for protective housings without interlocks.
This equipment complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received including interference that may cause undesired operation.
Complies with 21CFR1040.10 CAUTION - Laser light when open. DO NOT STARE INTO BEAM.
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Besides periodic calibration, your Webscan system requires a minimum amount of care and maintenance. In a very dusty environment, it is necessary to clean the window surface from time to time. It is recommended that you use a soft cloth, similar to the type used on eyeglasses or camera lenses. Warm water may be used along with a gentle cloth. Slowly wipe up and down making sure to clean the entire width of the window.
Accuracy of the optical parameter measurements are to ISO15426 (Barcode Verifier Conformance Specifications), as follows: The arithmetic mean of the measurements on 10 scans on a Primary Reference Test Symbol shall be within Decodability: +8%, Rmin: +3%, Rmax: +5%, Defect: +8%, Modulation: +12% (not specified in ISO15426, but our specified tolerance)
Page 55
NOTE: The units of the tolerance are percentage of 100%, in other words reported units, not percentage of the reading. Example: For a Test Symbol with decodability of 88%, a reading in the range 80% through 96% is within these tolerances. In most cases, measurements are more accurate than those stated above.
a. Final Quality Grade: Scale of 0.0 to 4.0, to a resolution of 0.1. b. Individual Parameters: Reported on a scale of 0 to 100 with resolution of 1. The resolution of measurement is not an indication of accuracy.
Refer to of ISO/IEC 15426-1 and ISO/IEC 15426-2. All TruCheck models have a means of calibrating reflectance values against reference reflectance calibration samples. Two calibration points are used, one near the high reflectance end of the range and the other near the low reflectance end of the range. The reflectance calibration target specified by Webscan is the GS1 Calibrated Conformance Standard. This NIST traceable standard is a product of GS1, and is available through Webscan, Inc. or from GS1 directly. The calibration procedure specified by Webscan, Inc. is documented in the manual.
Temperature 0-40° C, Humidity: 5% - 95% non-condensing section earlier in this
Page 56
The following pages contain compliance certificates for existing Model numbers of TruCheck barcode verifiers as of the time of publishing of this manual. Contact Webscan if your model is not listed. Webscan certifies that the following product models: TruCheck Omni Series: Model# TC-830, TC-839, TC-836, TC-833, TC-827, TC-832, TC-840, TC-846 TruCheck Optima Series: Model# TC-829, TC-838, TC-835, TC-834, TC-842, TC-844 TruCheck 2D USB Series: Model# TC-823, TC-831, TC-826, TC-821, TC-832 TruCheck 2D DPM USB Series: Model# TC-824, TC-845, TC-825, TC-850, TC-853 TruCheck Laser USB: Model# TC-843, TC-854, TC-841, TC-847, TC-837, TC-848, TC-857, TC-851, TC-855 TruCheck Rover: Model# TC-501 Comply with GS1 system requirements for EAN/UPC Symbology, UCC/EAN-128 Symbology, ITF-14 Symbology, GS1 DataBar Symbology and GS1 Composite Symbology and GS1 Data Matrix. And furthermore, with the following applicable ISO/IEC standards: ISO 15415 ISO 15416 ISO 15426-1 and 15426-2 ISO/IEC TR 29158 (AIM DPM-2006) for Data Matrix (ISO/IEC 16023) ECC-200 (up to 48x48 matrix size) QR Code (ISO/IEC 18004) Aztec Code (ISO/IEC 24778) PDF 417 (ISO/IEC 15438). Evidence of compliance with the aforementioned standards and traceability to National Institute of Standards and Technology (NIST) is provided through the use of GS1 Certified Calibrated Conformance Standards which are manufactured to exacting specifications and test for conformance to ISO 15426 parts 1 and 2. Webscan tests each unit for conformity within specified tolerances per ISO 15426 parts 1 and 2.
Page 57
Some barcode symbologies (especially 2D symbologies) can encode ASCII characters that are unprintable and therefore difficult to represent in the printed reports. A special pattern is used to represent these characters using a consistent notation of two letters, which represents the ASCII code, surrounded by brackets. The codes are as follows: ASCII Code Value (decimal)
ASCII Code name
Special Pattern Used
0
NULL
<NU>
1
SOH
<SH>
2
STX
<ST>
3
ETX
<ET>
4
EOT
<EO>
5
ENQ
<EN>
6
ACK
<AC>
7
BEL
<BE>
8
BS
<BS>
9
HT
<HT>
10
LF
<LF>
11
VT
<VT>
12
FF
<FF>
13
CR
<CR>
14
SO
<SO>
15
SI
<SI>
16
DLE
<DL>
17
DC1
<D1>
18
DC2
<D2>
19
DC3
<D3>
20
DC4
<D4>
21
NAK
<NK>
22
SYN
<SY>
23
ETB
<EB>
24
CAN
<CA>
25
EM
<EM>
26
SUB
<SU>
27
ESC
<ES>
28
FS
<FS>
29
GS
<GS>
30
RS
<RS>
31
US
<US>
Page 58
NOTE: The special patterns always consist of two letters, even though the name of the ASCII code sometimes contains more than two characters (example EOT, BEL, etc.). This is to preserve regular column spacing in the printed reports and to make it easier to parse the data strings.
This section contains information about specific symbologies and points out specific parameters that will be reported particular to that symbology.
UPC/EAN is a family of linear barcodes used at point of sale. The structure of a UPC/EAN barcode consists of leading guard bars, central guard bars, and trailing guard bars. The data characters consist of 4 elements comprising 7 unit modules, which encode digits 0-9. UPC codes encode 12 digits and EAN codes encode 13 digits. The first digit in an EAN barcode determines the GS1 country code of the country that the company is based. It is customary to report the size of a UPC/EAN symbol in terms of magnification, not by X dimension. Therefore, when UPC/EAN symbols are verified, the General Information section will contain a parameter called "Magnification". (Note: A 100% Magnification UPC symbol has an X dimension of 13 MILS, or .013 inch).
Code 128 is a very common and popular linear symbology. It has been adapted for use with the GS1 system, and barcodes utilizing the GS1 format of Code 128 are known as either UCC/EAN-128 or now GS1-128. A GS1-128 barcode contains a Function-1 character immediately after the start character. The structure of a Code 128 bar code consists of a start character, a variable number of data characters, a check digit character and a stop character. Each character consists of 6 elements (3 bars and 2 spaces) comprising 11 modules, except the stop character which contains an extra bar at the end which serves to close off the last space of the stop character. Data is encoded in one of three character sets (referred to as character Set A, B, and C), allowing for double density numeric encodation as well as encoding all possible ASCII characters (ASCII values 0 through 127). Code 128 is embodied in many application specifications, including barcode GS1-128 symbology (formerly UCC/EAN-128). The Code 128 symbology can encode data using three different "character sets" or more specifically, mappings between symbol characters and data characters known as Character Set A, Character Set B, and Character Set C. The Data Detail Tab will show the encodation of Code 128 symbols, displaying each symbol character and the corresponding data encoded. The particular start character that was used, control characters that switch between character sets, check digit, and stop characters are all shown. The data encoded uses the two-character notation for unprintable ASCII characters defined in 14.2 ASCII Code Representation.
Page 59
For Code 128, the element widths will contain a summary showing minimum, average, and maximum values for one, two, three, and four module bars and spaces separately, as well as the measured elements’ widths and deviations from nominal.
W
E
B
S
C
A
N
Code 39 is a discrete two-width symbology composed of characters containing nine elements, three of these nine being wide elements. The wide elements are a fixed multiple of the narrow element width. The multiple should be in the range of 2 to 3. This multiple is commonly referred to as the "Ratio" and is reported in General Characteristics.
The TruCheck also supports TLC 39. TLC 39 is a variant of Code 39 created to support a linked composite component for Telecom applications.
Interleaved 2 of 5 is a continuous two-width barcode symbology. ITF 14 is a GS1 form of I 2 of 5, and the TruCheck™ USB software will evaluate symbols encoded according to selected standards, either I 2 of 5 standard, or GS1 – ITF14. In order to select which standard is applied, there is a drop down menu box in the decode options of the settings window. Since Interleaved 2 of 5 is a two-width symbology, ratio will be reported in General Characteristics.
0 1 2 3 4 5
Code 93 is a linear symbology composed of characters made up of six elements fit into 9 modules. W E
B
S
C
A
N
Pharmacode symbols (also known as "Laetus Pharmacode" are linear symbols that contain no start/stop characters. By default, the TruCheck™ verifier will not detect Pharmacode symbols, so if Pharmacode symbols are to be verified, there is an option in the “type of code” section of the settings menu that must be checked. It is recommended that you activate this setting only when needed, because stray marks and other types of symbols can sometimes have the proper spacing to qualify as a valid Pharmacode symbol. This issue can be avoided by turning off Pharmacode whenever Pharmacode symbols are not being verified. Due to the lack of any start character or other means to determine the forward direction of the symbol, a Pharmacode symbol can read differently in each direction. Therefore, the data in a Pharmacode symbol is reported twice, in both the data field of the main screen, as well as the data detail tab. An “F”, expressing the data as interpreted by a foreword scan, indicates the first. The second is indicated by an “R”, indicating the data as interpreted by a reverse scan.
Page 60
0
1
2
3
4
5
MSI and Plessey codes are continuous binary symbologies in which data is encoded by groups of 4 bars and four spaces. Each bar/space pair represents a one or zero based on whether the bar or space is wide while the other is opposite. Groups of four such "bits", form a character. There is a check digit at the end, which can be displayed or removed from the data on the report depending on a settings choice.
The design of PDF 417 provides for the symbol being “line scanable”. First, each row is composed of self-clocking characters, much the same way as an ordinary linear barcode. The ’417′ in the name of the symbology comes from the structure of each character. It is 8 elements (4 bars and 4 spaces) arranged within 17 unit modules. (The ‘PDF’ part of the name stands for ‘portable data file’ and suggests that the data capacity of the symbol is large enough to represent all of the data associated with the item that the label is on, as opposed to a number that refers to a record in a non-portable data file (such as a price look table) in a computer database. Each row can be read in a way that is similar to the process of reading a linear barcode. However, each row further contains a special character at each end (adjacent to the start and stop characters) which identify the row number within the symbol for this row. There is also other information in these special characters, including the total number of rows and the total number of columns in the symbol. In this way, a scan of a PDF 417 symbol can yield part of the decode information of the symbol which can be combined with other scans (of the other rows) to result in a complete decode. Thus, PDF 417, like other multi-row stacked symbologies are “line scanable”. For PDF 417, the number of rows and columns (in the data section, not including the row indicator columns) will be given in the General Characteristic’s section, along with Error Correction information, such as Error Correction Level (which can be 0 through 8), Error correction budget, number of errors and erasures. In addition, the scan-reflectance-profile grade for the start and stop characters is given in General Characteristics for each in tracing the cause of the final grade. General Characteristics will also contain the Aspect Ration which is the row height divided by the module size. (Thus, a symbol with row height that is 3X will have aspect ratio of 3). Also, a Compact PDF 417 symbol (one with its right row indicator and stop character) will be noted in General Characteristics.
GS1 DataBar is a linear symbology that can be printed in multi-row stacked forms in many cases. Even GS1 symbols that have only 1 linear component should be treated 0 0 0 0 0 0 0 0 0 0 1 2 3 6 as stacked symbols for the purposes of setting up a scan region. GS1 DataBar must be enabled in the “type of code” section of the settings menu. The “# of scans” option in the settings menu has no effect on GS1 DataBar symbols; the appropriate number of scans will be decoded according to the technical specifications, and is typically ten per row, or composite section of the overall code.