The text of a manual · part 4 of 7
Webscan Barcode Verifiers TruCheck User Manual, pages 31 to 40
Pages 31 to 40 of 68
The original document is the PDF (5.0 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the Webscan TruCheck TC-418, Webscan TruRemote TC-403, Cognex TruCheck TC-418 and Cognex TruRemote TC-403
Page 31
Codewords- Reports on the codewords for PDF-417, MPDF, CC-A, CC-B, and CC-C symbols. Image of Symbol- Includes an image of the symbol on the report. ECC Details- Report will include information about the error correction process.
Page 32
This is an example of the 2D settings screen. You can access this screen from the options menu in the upper left hand corner of the interface.
Alternatively, you can simply click the 2D button (depicted below) also located in the upper left hand corner of the interface.
One or more symbologies can be selected, but it is recommended for speed that only the symbologies used in the desired application be selected. Aperture Size- This is the sampling size used to test the reflectance values of individual elements within the code or finder pattern, and can be selected or entered manually. ‘Auto Aperture’ uses what would be appropriate for the application specification and/or code size – Auto 80% uses a test aperture 80 percent of the size of the barcode’s X dimension. Aperture size has an effect on the grade. Bigger apertures will see bar width growth as being detrimental, smaller apertures may be negatively impacted by defects. Aperture size can be called out in the application specification, quality specification, or both.
Page 33
Application standards configure the verifier to grade according to an individual entity’s rules for what criteria is to be used to grade the codes and whether or not the encoded data meets the data formats for the application. 2D application standards currently implemented are the GS1 rules and the US DOD UID mandate. GS1- Selection will auto select the correct test aperture if selected as ‘Auto Aperture’ and will require the data format to meet the rules as well as a quality grade of ‘C’ or better. GS1-Auto- When the code has a Function 1 character encoded as the first character, the code will be graded according to what is spelled out in the ‘GS1 General Specification’. Codes not encoded with the Function 1 character will not grade according to GS1 rules. GS1-Always- Would require the code be GS1 formatted in order to get a passing grade. Codes not encoded with the Function 1 character will fail. MIL-130-STD UID- This application standard will properly report the quality standard used to grade the code and data structure used when unique identifiers are created. The Military Standard spells out what standard grades are acceptable and users are reminded when a selection doesn’t meet the revision level or where data is not properly formatted. Pass Grade- Users may simply want to select a minimum passing grade based on a certain letter on numerical grade value. (A-F or 0.0-4.0) UDI/HIBC – This application standard checks symbols that meet UDI requirements using either GS1 or HIBCC guidelines. Format Check ISO/IEC 15434 – This application standard checks data for many industry standards which encode information using ISO/IEC 15434 data structures.
Dot Peen- Use this option for barcodes created with the dot peening process, which is a process where dots are peened onto a metal surface. This helps connect the dots in the decode process.
Page 34
Invert Image- For images printed white on black. X-Dimension Range- Utilized with the AIM-DPM quality standard to define the range of X dimensions used to decode a symbol, also used as stick size range when utilizing the DOT PEEN option. Avg Angles- Are used when the now obsolete version of ISO-15415 is used to verify Data Matrix. Angles are created on the user interface to assist in the alignment of the code where the grade was based on an average of five different scans at different angles. The options below only pertain to QR Code. ISO-18004 Compliant- Verifies QR code in strict adherence to the ISO-18004 specification Adjust for Substrates- Uses a one module quiet zone to threshold the light space elements. This is beneficial for QR Codes printed on films or plastic where the internal spaces cannot achieve the reflectance levels of a four module quiet zone. This helps a printer determine print quality without modulation degradation due to substrate. Mobile QR (Reduced QZ) – Only one module quiet zone is tested. Printers can check print quality ignoring artwork that interferes with the 4 module quiet zone specified in ISO-18004. Override acceptance criteria to Warn or Fail when the grade is close to boundary conditions. This is a Webscan proprietary measurement, based on calculations that predict whether slight variations in the image, could produce a large change in the "grid" of module centers which could potentially change the overall grade of a data matrix symbol.
These are the selections that determine what Quality Standards and optional sections will print on the reports.
Traditional Parameters- Includes Minimum Reflectance Difference (MRD) in the reported General Characteristics both in the verification report and on the user interface. MRD quantifies the minimum difference anywhere across the barcode. These worst-case black and white modules need not be adjacent to one another. Image of Symbol- Puts the image used for verification on the verification report. ASCII Values- Turns on the reporting of the encoded ASCII values. Values are reported on the verification reports as well as in the “Data Detail” tab.
Page 35
ISO-15415- Reports and displays in accordance with the International Standards Organization Barcode Quality test specification for two-dimensional symbols. Selecting this standard allows for the selection of ISO 15415 reporting options: AIM-DPM- Select this if you want to utilize the AIM-DPM verification standard. This can be selected with or without the Dot Peen selection. AS-9132- Reports and displays in accordance with the SAE AS9132 quality requirement standard for part marking Data Matrix code. This option is only selectable when Data Matrix is chosen in the Symbologies. Cell Size Diagnostics- Enables reporting detailed clock track information showing heights and width for Data Matrix clock track elements. AIM:ISO (ISO 16022:2000) – Reports and Displays in accordance with the ISO-16022 Symbology and Quality Specification for Data Matrix code. See Table 3.1 for information pertaining to this standard. This option is only selectable when Data Matrix is chosen in the Symbologies. All other reporting options are organized by grading standard. The following reporting options have the same meaning regardless of under which standard they appear: Quality Parameters – Enables reporting of a standard’s quality parameters and their corresponding values and grades. Selecting this is highly recommended, as this information makes visible the reasons for poor results in a standard. Mod Values – Reports show the individual modulation values from each data cell in the symbol. Modulation values can be viewed on the User Interface “Advanced” tab regardless of this selection. (See also:"Contrast Uniformity" on page Codewords – Turns on reporting of the codewords when verifying symbols. Values are reported on printed and saved reports as well as in the “Data Detail” tab. ECC Details – Turns on reporting of error correction details, which appear within the “General Characteristics” tab. Suppress on Fail – In verification, if the symbol fails (grades below the pass grade of) the standard, and it passes another selected standard, and then this standard’s results will not be included on the verification report. For example, if this option is set in the ISO 15415 standard options and both the ISO 15415 and AIMDPM standards are enabled, and the ISO 15415 grade for the verification is below the pass grade while the AIM-DPM grade is at or above the pass grade, then the ISO 15415 standard results will not appear on the verification report.
Page 36
When “Save Report” is selected, the type of reports that will be saved are these selections. One or more must be selected when Save is on. If a strip report is desired, the option for Thermal, Dot Matrix and Generic can be selected. The Thermal and Dot Matrix options support the Star character print set.
Auto Print Report - This option will trigger a report be printed to the ‘Default Windows Printer’ every time a code is verified. Auto Print Strip Report– Same as above but the report is printed to a Windows installed Strip Printer. Auto Print Summary - In Multi-Mode, where summary reports are created, they can be automatically printed for each verify. Auto Prompt for Excel - If Excel functionality is required and no template is open, this will prompt the user to open a sheet. CSV Scan Details - This option will populate the Excel sheet with all 10 scans or “# scans” from the “1D Setting Menu”. The default is one line in the Excel sheet for each verify. Save Report - This option saves reports electronically to the path defined next to it. The path can be a local hard drive or file server the user has permission to write to. Several settings define what the reports contain and what formats to save. Append PDF - This option is used if multiple reports are to be saved in one Adobe PDF file. Enter the file location and name, and as long as this option is selected, all reports will be appended. Save Summary Report– In Multi-Mode, summary reports can be saved. If this option is not selected and ‘Save Report’ is selected, Multi-Mode individual, reports will be saved but not the summary. Append Summary PDF - Same as Append PDF but for Multi Mode Summary reports
Page 37
Define Report File Name Format - Saved reports are named in a default format consisting of SymbologyData– Date Stamp. Alternate naming conventions can be defined as seen below. Select the fields in order from “Available Fields” to “Selected Fields”.
This option can be accessed from the “File” menufollow the drop down and click on “User Password Options”. You will be prompted to enter a password; the default is “user”. The password protection is provided for the settings menus and the calibration menu. NOTE: The default password is “user”, all lower case.
“User Information” can be found in the “Options” menu under “User Information”. This information is also in the “Settings” screen, under the “Report and Print Options” section. User Information- Information required on reports can be selected here. Company Name, Operator, Product Name, Batch #, Job Number, and a Logo path can be defined. If you check the “Windows User Name” box, the “Operator” field will be automatically filled in with the username of the user logged into Windows. This dialog box can also be selected from the ‘Options Menu -> User Information’.
Page 38
This feature can be accessed by going to the “Help” menu and following the drop down to “Revision Log”. The “Revision Log” gives you a history of revisions to the software. This will allow you to document or review changes made in the latest software update.
This feature can be accessed by going to the “Help” menu and following the drop down to “About.” The “About” screen will show you your current version of software and its release date.
Page 39
The ANSI parameters section lists each of the nine ANSI parameters and gives a summary of the measurements based on all scans taken. Each parameter is completely explained below. Note that some of these parameters are average values over all of the scans, and the averages may skew or alter the apparent results. For a rigorous review of the ANSI process given on each of your codes, you should check the ANSI Matrix for each code, described in the next section. This section may be very helpful in situations where the barcode cannot even be read. Therefore, the descriptions of each parameter below will explain what is measured in the case where a code is read and not read. When a code is not read, the scan is analyzed for apparent quiet zones, and the bars and spaces in between are used for the ANSI analysis. 1. EDGE: Edge Determination Checks that each edge between bar and space can be detected and no false bars or spaces appear due to “splitting” of bars or ink splattered into spaces. If at least one scan results in a decoded barcode, the EDGE value is the number of bars and spaces, not including quiet zones, in the code. If no scans result in a decoded barcode then the EDGE value shown is the number of bars and spaces found between quiet zones (or apparent quiet zones) on the scan on which the most bars and spaces were found. The Scan Reflectance Profile graph can also be very helpful in analyzing a code that cannot be decoded. 2. Rl/RD: Minimum Reflectance Checks that the darkness of the bars is sufficient. Strictly speaking, the amount of light reflected by the bars (bar reflectance) must be less than half the light reflected by the spaces (space reflectance). The values shown are the light reflectance and the dark element reflectance separated by a slash. The light reflectance is the maximum reflectivity found in the scan (lightest or best space), and the dark reflectivity is the minimum reflectivity found in the scan (darkest or best bar). The requirement is for the minimum reflectivity to be no more than half the maximum reflectivity. If this requirement is met, the grade will be A, otherwise it will be F. 3. SC: Symbol Contrast Measures the contrast between the brightest space and darkest bar. The result is assigned a letter grade of A, B, C, D, or F, with A being the highest contrast. The contrast is the difference between the maximum reflectivity (lightest or best space) and the minimum reflectivity (darkest or best bar). Note that Symbol Contrast is the difference between light and dark, and Rl/Rd above checks the ratio of these values. A > 70 B 55-70 C 40-55 D 20-40 F <20 4. MinEC: Minimum Edge Contrast Checks that the contrast between adjacent bars and spaces is high enough. When a barcode is scanned, a reading device must locate the edges between each bar and space. If the difference in the light and dark elements is not significant, this may not be achieved. Note that MinEC finds the worst-case contrast difference between each bar to space transition, whereas symbol contrast finds the best-case difference at any point across the barcode.
Page 40
5. MOD: Modulation Modulation checks the edge contrast as a fraction of the overall or best case contrast measured in symbol contrast. Modulation is an important measure of minimum edge contrast since most barcode reading devices employ “adaptive thresholding circuits” of some type that are sensitive to a symbol’s contrast in order to detect transitions between bars and spaces. If all bars and spaces were the same brightness, the minimum edge contrast would be equivalent to symbol contrast. In this case, modulation would be 100 percent. If some spaces are less bright than the brightest one, modulation will be some fraction of the overall contrast. Modulation therefore measures the amount of available contrast that is manifested in the worst-case bar to space transition. The percentage is assigned a letter grade. Excessive ink spread or bar growth can result in low modulation because very narrow spaces appear to be filled in by the encroaching bars in the Scan Reflectance Profile. If you have read down to here, you deserve a reward! Call Webscan at 1-877-WEBSCAN for your FREE gift. 6. Def: Defects The worst-case change in reflectance within a single bar or space is a defect. The largest difference in reflectivity found in a single bar or space is measured as a percentage of the symbol contrast and assigned a letter grade. Defects normally measure breakups or voids within bars, ink spots in spaces, or even the grain of a substrate in spaces. This very serious issue for scanners was not directly addressed by traditional verification techniques. 7. DCD: Decode The widths of each bar and space are measured and used to interpret the data content of the barcode according to a specific mathematical formula appropriate for the barcode type. If the barcode cannot be decoded according to the formula, the accuracy of the bar and space widths are inadequate. The printout shows the number of scans decoded over the number of scans taken, e.g. 8/10 means 8 out of 10 scans decoded. 8. DEC: Decodability Determines how accurate the bar and space widths are and how easily the widths can be determined. A perfectly accurate barcode will have 100 percent decodability, but decodability as low as 25 percent is often acceptable. Decodability is always measured in terms of the formula used to interpret the bar and space widths into the data content of the barcode. In order to read barcodes, thresholds between element widths are normally established according to prescribed “decode algorithms”. Decodability is normally the percentage of the overall tolerance range for a bar or space width that is not used up by inaccuracies. See Appendix B for an example. 9. QZ: Quiet Zone This refers to a dedicated amount of blank space on the left and right of the barcode. Each symbology specifies a minimum quiet zone. For example, UPC-A barcodes should have at least a nine module quiet zone on each side, whereas an EAN-13 barcode permits legal quiet zones to be as small as seven modules.