Page 28

Page 28 of 41

Chapter 4. HARDWARE OVERVIEW 4.1 INTRODUCTION The WDT2200 is a handheld data terminal that has an integrated laser-scanning module or clipon pen module for bar code reading. A rechargeable Li-ion battery pack powers the WDT2200. A CR2032 lithium button cell backup battery preserves data stored in RAM when the power main battery is used up or during the replacement of the main battery.

WDT2200 Hardware Configuration

© 2003 Wasp Technologies, Inc.

Page 29

Page 29 of 41

4.2 FEATURES • • • • •

16-bit Microprocessor, 16Mhz Clock Real Time Clock Integrated Circuit (IC) 2.5MB CMOS (RAM) Memory.

• • •

3V 190mAH Lithium Data Backup battery. Power Low Status Indicator for Main and backup batteries.

26 alphanumeric rubber keys with 1 scanner trigger switch 128x64 pixel graphic backlit LCD with selection between 16-column by 4-line in 8x16 font and 20-column by 8-line in 6x8 font • Power by Li-ion @ 3.6V 880mAH Rechargeable Battery-pack.

4.3

256KB Flash ROM, 128k for DOS-based system, the other 128K for user application program use.

I/O Ports 4.3.1 The WDT2200 has three interface ports: An RS232 I/O serial port can be used to communicate with a host PC and normal charge from RS232 cable when cable is connected with 9VDC/1A power adapter. Pin

1 2 3 4 5 6 7 8 9 10 11 12 4.3.2

Signal

Direction

DCD RXD TXD

Input Output

Receive date Transmit date

DTR

Output

Data Terminal Ready

GND

Reference

Ground

DSR

Input

Data Set Ready

RTS CTS

Output Input

Request to send Clear to send

RI Bat(+) Bat(-) Ext 9V

Description

Not support

Not support

Scanner The WDT2200 has provision for an integrated laser or CCD scan engine and a built-in decoder for reading bar code labels. There is a single scanner-trigger switch above the keypad. The scanning window of the integrated unit sits flush with the top surface of the portable terminal.

© 2003 Wasp Technologies, Inc.

Page 30

Page 30 of 41

4.3.3

WDT2200 CHARGING/COMMUNICATION CRADLE

An optional charging/communication cradle (docking station), gives users a convenient environment for daily use of the WDT2200. The cradle has provisions for a quick charge circuit to fully charge the main Li-ion battery pack installed in the unit in about 2~3 hours. The cradle also allows users to link the WDT2200 to a host computer through RS-232 for data communication.

© 2003 Wasp Technologies, Inc.

Page 31

Page 31 of 41

5

COMMUNICATION INSTALLATION

The RS-232 port of the WDT2200 can communicate with the serial port of a host computer. There are two ways to carry out communication sessions: (1) LOCAL

: Directly connect to the serial port of your computer system.

5.1.1 LOCAL CONNECTION: In the Local connection method, the WDT2200 is directly connected by a null modem cable to the serial port of the host computer. This is the way to download or upload files from/to your WDT2200. Note that the communication parameters must be matched on your WDT2200 and host computer or the communication will fail. CONNECTING THE WDT2200 TO A HOST COMPUTER Host Computer 9 Pins

2 RXD 3.TXD 5 GND 7.RTS 8 CTS

WDT2200

3 TXD 2 RXD 5 GND 8 CTS 7 RTS

When the flow control is set to CTS/RTS, the CTS (RTS) signal of one end is necessary to be linked to the corresponded RTS (CTS) on the other end. © 2003 Wasp Technologies, Inc.

Page 32

Page 32 of 41

5.1.2 REMOTE CONNECTION: The remote connection of the WDT2200 is established by linking a pair of modems through the telephone line. Once your WDT2200 has been connected with a modem to a telephone line, you can dial from the WDT2200 to a remote host computer. The computer needs to be attached to a modem through the telephone line. After the line is connected, the data communication process can start between the WDT2200 and PC/Host as if the two were linked locally. CONNECTING THE WDT2200 TO A external MODEM : WDT2200 Modem

2 RXD 3 TXD

2 RXD 3 TXD

4 DTR 5 GND

6 DSR 7 GND

6 DSR 7 RTS

20 DTR 5 CTS

8 CTS

4 RTS

© 2003 Wasp Technologies, Inc.

Page 33

Page 33 of 41

5.3

DOWNLOADING AND UPLOADING

The WDT2200 supports the MULTI protocol and ESC commands for serial data communication. Once the WDT2200 and PC are physically connected, a data communication processing will be established when a program running on the PC sends the ESC command consistent with the protocol specified in the WDT2200. Connection Point-to-point Multi-point

Protocol supported OFF, or MULTI MULTI

Before you download or upload a file from the PC to the WDT2200, connect your WDT2200 and HOST using the LOCAL method.

© 2003 Wasp Technologies, Inc.

Page 34

Page 34 of 41

5.3.1

Downloading an AppGen Pro application from Host to WDT2200

This function downloads an existing AppGen application from the host to the WDT2200. On the WDT2200: • Connect the RS-232 port of the WDT2200 to the COM port of your PC by a null modem cable. • Press the power key to turn on the WDT2200. • Check the protocol and communication parameters of the WDT2200. These settings must match the settings as defined in the configuration of the AppGen application program. If the AutoSeek baud rate function is enabled on AppGen’s PTComm Manager, you don’t need to be concerned about the WDT2200’s baud rate setting, but Protocol setting should be set as Multi and the other communication parameters should be set to “N,8,1”. On the HOST: • Run the AppGen program. • Open the job file which is targeted to run on the WDT2200. • Press F4 key (or click the Make Job icon, or select Built Make Job). 5.3.2

Uploading AppGen data from WDT2200 to HOST

Having collected the data into the WDT2200, the user can upload one or more collected data files to a PC. On the WDT2200: • Connect the RS-232 port of the WDT2200 to the PC’s COM port PC with a null modem cable. • Press the power key to turn on the WDT2200. • Check the protocol and communication parameters of the WDT2200. These settings must match the settings as defined in the configuration of the AppGen application program. If AutoSeek baud rate function is enabled on AppGen’s PTComm Manager, you don’t need to care about the WDT2200’s baud rate setting, but the Protocol setting should be set to Multi and the other communication parameters should be set to “N,8,1” On the HOST: Run the AppGen program. Press F10 key (or click PTComm Manager icon, or select Tools PTComm Manager Double click the Portable icon on right-upper windows and it will list all of the files which are stored on the WDT2200 • Click and drag the file which will be sent back to PC, dropping it into the left window at the correct folder. • • •

© 2003 Wasp Technologies, Inc.

Page 35

Page 35 of 41

5.3.3

Downloading a file from Host to WDT2200 using the Kermit Server

This function downloads a file from host to the WDT2200. On the WDT2200: • Connect the RS-232 port of the WDT2200 to the COM port of your PC via a null modem cable. • Press the power key to turn on the WDT2200. • Check the WDT2200 protocol and communication parameter settings. • Press and hold down the [CMD] key for 2 seconds to enter User mode, then select “3.COM” in User mode to enter Kermit server mode. (See On the HOST, immediately below, to do file downloading from the Host side). Note : You can press [CMD] and [Alpha] to exit the Kermit server and return to Ready mode On the HOST: • • •

Run the WDT2200’s KERMIT.EXE utility program on the Host PC. First set the communication parameters to match the portable’s, then invoke the download command by entering “SEND filename”. Enter [Q] to return to DOS.

© 2003 Wasp Technologies, Inc.

Page 36

Page 36 of 41

5.3.4

Uploading files from WDT2200 to HOST using the Kermit Server

Having collected the data into the WDT2200, the user can upload one or more collected data forms to your PC. On the WDT2200: • Connect the RS-232 port of the WDT2200 to the COM port of your PC with a null modem cable. • Press the power key to turn on the WDT2200. • Check the WDT2200 protocol and communication parameter settings. • Press and hold down the [CMD] key for 2 seconds to enter the User mode, then select “3.COM” in User mode to enter the Kermit server mode. (See On the HOST, immediately below, to do file uploading from the Host side) On the HOST: • Run the WDT2200’s KERMIT.EXE utility program on PC. • First, set communication parameters to match the portable’s, then invoke the upload command by entering “GET filename”. • Enter [Q] to return to DOS.