Page 37

Page 37 of 41

6

Troubleshooting

1. If the low-power icon indicator of the main battery is shown on the LCD screen: Charge the battery pack for 2~3 hours. 2. If can not power up the WDT2200 after pressing power key: •

Charge the battery pack for 2~3 hours.

3. If you can not power up the WDT2200 after charging battery pack for 2~3 hour: • •

Check if the battery pack is placed and connected properly in the battery compartment, or Replace the battery pack and charge it for 2~3 hours. If problem persists, call for service.

4. If the WDT2200 does not upload data to host: • •

Confirm that the WDT2200 communication parameters (COM port, baud rate, data bits, parity, stop bit ) match the Host’s settings, or Confirm that the communications cable is plugged in tightly, or

5. If host can not download application programs to the WDT2200: • •

Confirm that the WDT2200 communication parameters (COM port, baud rate, data bits, parity, stop bit ) match the Host’s settings, or Confirm that the communications cable is plugged in tightly.

6. If the scanner does not scan: • • •

Check if the type of scanner port is set correctly, or Check if the symbology used is enabled, or If it still fails, call for service.

7. If the keypad does not work properly: • •

Verify operation steps against the user manual, or Power the WDT2200 off and on, then press some keys to check if an audible beep is generated for each key pressed. If not, call for service.

© 2003 Wasp Technologies, Inc.

Page 38

Page 38 of 41 8. If encounter any other abnormal symptoms:

Caution: The following process will clear all data in the WDT2200 RAM disk memory) Reset (cold start) the WDT2200, press [CMD], [ ] and the power key simultaneously, press [3] in “Start Menu” press ENTER. See if the symptoms go away. If not, call for service.

© 2003 Wasp Technologies, Inc.

Page 39

Page 39 of 41

7

POWER SOURCES

A rechargeable Li-ion battery provides the main power source. A Lithium button cell battery is used to back up the system’s real time clock and content in the RAM memory when the main power source is not available. NOTE. When using the WDT2200 for the first time, the main battery must be charged for 3 hours. The WDT2200 checks the power level of the main battery when the portable terminal is in use, however, the backup battery is only checked during power-on-test. Either low battery condition will signal the user via a warning message on the LCD. When the main battery reaches a low condition, the LCD flashes a warning Message (“Main Battery Low”) at one minute intervals while the portable terminal is on. The main battery can continue to supply power in normal operation for approximately 10~30 minutes. However, the level may reach the WDT2200 power cutoff point and automatically turn the Portable terminal off. In this situation, the lithium battery continues to back up data and application programs in RAM and the WDT2200 cannot be powered up until the main battery is recharged or replaced.

© 2003 Wasp Technologies, Inc.

Page 40

Page 40 of 41

7.3

MAIN/BACKUP BATTERY REPLACEMENT AND INSTALLATION Main Battery 1. Make sure the unit is turned off.

2. Turn the unit face down. Turn the locking screw counterclockwise ¼ turn.

3. Remove the main battery pack from the battery compartment. Do not disturb the backup battery in the lower compartment or all data will be lost! 4. Insert a new main battery pack and replace the cover.

Lithium Back up Battery 1. Remove the main battery, as above, then remove the backup battery cover and the backup battery itself. 2. Insert a new CR2032 Lithium battery into the backup battery holder with correct orientation.

3. Insert the main battery pack, replace the cover and tighten the screw. Back up your PDT data replacing the Lithium backup battery!

© 2003 Wasp Technologies, Inc.

Page 41

Page 41 of 41

7.4

MAIN POWER BATTERY CHARGING WITH AC/DC ADAPTOR (Regular/Normal Charge)

When the PDT shows the “Main battery low” message or icon, the battery pack in the WDT2200 needs to be recharged. Plug one end of an AC-9VDC/1Amp power adapter into the DC-jack of RS232 cable and the other end into a wall outlet. The battery pack will be fully recharged after 2-3 hours. The WDT2200’s CR2032 Lithium backup battery is not rechargable. 7.5

MAIN BATTERY CHARGING WITH CRADLE

Connect power adapter to the cradle and insert the WDT2200. The battery of PDT can be fully charged in about 2~3 hours and the status of battery charging is indicated by the LED on the front panel of the cradle. The LED will be red when charging and green when the main battery is fully charged, ready for use.

© 2003 Wasp Technologies, Inc.

Page 42

Page 42 of 41

7.6

MAIN BATTERY STORAGE & SAFETY PRECAUTIONS

Charging Considerations It is important to consider the surrounding temperature whenever you are charging the Li-ion battery pack. The process is most efficient at normal room temperature or slightly cooler. It is essential that you charge batteries within the stated range of 32°F to 113°F (0°C to 45°C). Charging batteries outside of the specified range could damage the batteries and shorten their life cycle. Effects Of Overcharging Batteries Overcharging may occur when a Li-ion rechargeable battery is charged at a regular or quick charging rate after it has been fully charged, but there is no risk of overcharging while charged in trickle charging rate. If Li-ion batteries of the WDT2200 are charged by a power adapter plugged directly to its DC jack for too long, they can sustain a temporary reduction of capacity due to overcharging. A battery left to charge for several weeks may appear to have minimal capacity. This type of failure can be remedied by temporarily depleting the battery of its power and recharging it to rejuvenate it. This condition can be prevented by avoiding overcharging for long periods of time or always using the cradle to charge the batteries of the PDT. The cradle starts the charging process in quick charging rate and switches to trickle charging rate when it detects the battery is fully charged. Storage and Safety Precautions Batteries should be stored in an open circuit condition and placed where there is no risk of accidental shorting or other damage. Although charged Li-ion batteries may be left unused for several months, their capacity may be reduced due to internal resistance. If this happens, they will require recharging prior to use. Li-ion batteries may be stored at temperatures between -4°F and 158°F (-20°C to 70°C), however they may be depleted more rapidly at the high end of this range.

© 2003 Wasp Technologies, Inc.