Page 19

Page 19 of 41 Send/No-send Leading Digit (SEND) Send/No-send Check Digit (SEND) UPC-E

Enable/disable decoding (ON) Send/No-send Leading Digit (SEND) Send/No-send Check Digit (SEND) Enable/disable Zero-Expansion (OFF)

EAN-13

Enable/disable decoding (ON) Send/No-send Leading Digit (SEND) Send/No-send Check Digit (SEND)

EAN-8

Enable/disable decoding (ON) Send/No-send Check Digit (SEND)

EAN/UPC ADD-ON Disable/Optional/Required (DISABLE) Send/No-send Check Digit (SEND)

3.2.3.2

Code 128

Enable/disable decoding (ON)

EAN 128

Enable/disable decoding (ON)

Code 93

Enable/disable decoding (ON)

Code 32

Enable/disable decoding (ON)

User code 1

Enable/disable decoding (OFF)

User code 2

Enable/disable decoding (OFF)

ASCII Terminal Configuration

The TERM command enables the WDT2200 to run a built-in Terminal emulator. The WDT2200 will operate as a dumb ASCII terminal when the user select this feature and disable the FormCaching menu.

When the TERM SETUP menu (shown below) appears on the WDT2200 LCD, proceed to set up the portable terminal communication parameters. When finished, go to the User Mode menu and press 2 (2.TERM) to make the WDT2200 operate as an ASCII dumb terminal. Terminal ID Each WDT2200 "Terminal" can be identified by an 8character string Terminal ID assigned by the user. Initially, the default ID is "WDT2200". Valid characters for assigning Terminal ID are alphanumeric characters ('A'-'Z', '0'-'9'). Hit [ENT] to make the selection. © 2003 Wasp Technologies, Inc.

<<TERM SETUP>> TERM ID.

WDT2200

Page 20

Page 20 of 41

Online

Use the [ ] key to toggle between REMOTE and LOCAL, then hit [ENT] to make the selection.

<<TERM SETUP>> ONLINE REMOTE

REMOTE The WDT2200 will output data gathered from the bar code port or keypad to its RS-232 port. LOCAL The WDT2200 does not transmit gathered data to its RS232 port. Echo

Use the [ ] key to toggle between ON and OFF, then press [ENT] to make the selection. The collected data will be displayed on the WDT2200 LCD when Echo is set to ON, otherwise data will not be displayed when it is set to OFF.

AutoLF

Use the [ ] key to toggle between ON or OFF, then hit [ENT] to make the selection. When AutoLF is set to ON, the WDT2200 will append a LF (10 hex) character to the input data block.

Mode

Use the [ ] key to toggle between BLOCK and CHAR, then hit [ENT] to make the selection. See section 3.2.2 for the description of Block and Character modes.

Line/Page

Use the [ ] key to toggle among LINE, PAGE and BOTH, then hit [ENT] to make the selection. The Line/Page parameter is useful only if dumb terminal operation has been specified as BLOCK mode. The Line/Page entry designates the termination character. The termination character can be set as: LINE Line termination: CR ( 0D hex) PAGE Page termination: CTRL-Z ( 1A hex) BOTH Line termination and page termination

3.2.3.3

Memory Configuration

This feature allows the user to allocate available RAM between the Execution Program and RAM disk area, and can only be done when there is no data stored in RAM. The RAM memory in the WDT2200 is divided into three sections: ♦System Variable

About 29KB of RAM memory is reserved for WDT2200 parameters.

♦RAM Disk Area

Area used to store programs and data files, similar to a physical disk of a PC.

♦Program Execution Area

Area where the applications and data are loaded, similar to the main memory in a PC.

© 2003 Wasp Technologies, Inc.

Page 21

Page 21 of 41 To reallocate memory, go to the Supervisor Mode screen and press 3 (3.M_SIZE) to setup the Execution Program Area size, key in the new memory size then press [ENT]. You can allocate available RAM between the Execution Program and RAM Disk area. The size of RAM Disk will decrease when you increase the size of the Execution Program area, and vice versa. The second line in the EXEC MENU shows Min and Max number of kilobytes that can be allocated to the Execution Area.

3.2.3.4

FormCaching Application Program

FormCaching is a built-in application program that allows users to create a data entry application by specifying field prompt, field length, data type, input method and delimiter, etc. without writing a program and loading it (download or manually) to the WDT2200.

Enable the FormCaching application by selecting 4 (4.FORM) in the Supervisor mode menu. When FormCaching is enabled, the WDT2200 will first ask the user to specify data fields in four categories including field prompt, data length, and data type and device type. After defining all data fields, the user must press [CMD] then the [Alpha] key to end the setup of the data field.

© 2003 Wasp Technologies, Inc.

Page 22

Page 22 of 41 FormCaching Specification DATA FIELD DEFINITION: maximum field number=8 Category Range Description 1 FIELD PROMPT Max.16 characters set field prompting 2 MIN/MAX 1-48 set minimum field length DATA LENGTH and maximum field length 3 DATA TYPE 1.NUMERIC numeric data (0~9) or 2.ALPHANUM alphanumeric data (20H~FCH) 4 DEVICE TYPE 1.KEY ONLY input by keyboard only, 2.SCAN ONLY bar code scanning only or 3.BOTH both DATA RECORD DEFINITION Category Range Description 5 BETWEEN 1.APPEND SCREEN specify to clear or append screen FIELD 2.CLEAR SCREEN between two fields 6 FIELD 1. , 2. ; assign field delimiter DELIMITER 3.SPACE 4.TAB 7 RECORD 1.CR assign record delimiter DELIMITER 2.LF 3.CRLF 8 DATE STAMP 1.NONE 2.YYYYMMDD assign date stamp and specify the FIELD 3.MMDD 4.MMDDYYYY format of date stamp 5.DDMM 6.DDMMYYYY 9 TIME STAMP 1.NONE assign time stamp and specify FIELD 2.HHMM the format of time stamp 3.HHMMSS 10 FIELD DELAY 0-6 specify time delay between each record input in second

When FormCaching is enabled, a data file named FORM.DAT will be created in the WDT2200. FORM.DAT stores the data as entered by the user after FormCaching is invoked. The WDT2200 will not allow the user to redefine the data fields in FormCaching once the FORM.DAT has been created. The file FORM.DAT must be deleted in order to implement any change in the configuration of FormCaching. Running The Resident FormCaching Application Program Enable the FormCaching, the WDT2200 built-in application can be ran by switching the portable terminal to the User mode of operation and selecting “2.TER”, select “2.FORMCACHING”. The FormCaching application program will follow the setting (as previously defined by the user) as it displays prompts, requests input, and stores data in the FORM.DAT file. Pressing [CMD] then the [Alpha] key will abort the current record inputting action. The user may use the [ ] key to browse a previously input data record and press [CLR] to clear the record and then input new values. Pressing [CMD] then [Alpha] at the beginning of the first input field of a record will abort the FormCaching application and the portable terminal will go to the Ready mode. After collecting data, the FORM.DAT file can be uploaded to a Host/PC either by invoking the Kermit server in the User mode or remotely through the Windows-based, communication utility Communication Manager.

© 2003 Wasp Technologies, Inc.

Page 23

Page 23 of 41 WDT2200 FormCaching Defaults The WDT2200 enables FormCaching. By default, the following settings apply: DATA FIELD DEFINITION: field number=2 Category Setting Field #1 FIELD PROMPT ITEM: DATA LENGTH 32 DATA TYPE ALPHANUM DEVICE TYPE BOTH Field #2 FIELD PROMPT QTY: DATA LENGTH 4 DATA TYPE NUMERIC DEVICE TYPE KEY ONLY DATA RECORD DEFINITION Category Setting BETWEEN FIELD Append screen FIELD DELIMITER , RECORD FELIMITER CR DATE STAMP FIELD NONE TIME STAMP FIELD NONE FIELD DELAY 0

3.2.3.5

POWER or ON-OFF

The WDT2200 provides system power on/off feature. 1.)RESUME, 2.)AUTO OFF, or 3.)ALARM 1.RESUME

Once 5 is selected, user can define

When the Resume function is enabled, the WDT2200 will resume program execution from the last turn-off point when it is again powered on. The default setting is ON (enabled). 1. 2.

Press 1 (1.RESUME) At the STATUS SETUP Menu, use the [ ] key to select between RESUME ON (enable Recovery) and RESUME OFF (disable recovery) 3. Press [ENT] to complete the setting

2.AUTO OFF Use the [ ] key to set the auto-off timeout from 1 to 9 minutes. The WDT2200 will turn itself off automatically after being idle for the time period specified in the AUTO OFF setting. The default setting of AUTO OFF is 5 minutes. The auto-off feature is disabled when set to 0 minutes. A smart power management system is built into the WDT2200 hardware and software to conserve battery power. The WDT2200 power transition flow is as follows:

© 2003 Wasp Technologies, Inc.

Page 24

Page 24 of 41 program running press [PWR] (switch off)

ACTIVE wait on keyin/scan OR call INT 22H press [PWR] (switch on)

POWER ON

SHUT DOWN key in bar code scan RS232 input Auto-off timeout POWER FAILURE

STAND BY

NMI press [PWR] (switch off)

♦Active

All system hardware is activated in Active mode. The system will enter Stand-by mode if it waits on input or call INT 22H.

♦Stand by

In the Stand-by mode, if a key is depressed, a bar code or RS-232 input occurs the WDT2200 will return to Active mode. Otherwise, the portable terminal will enter Shutdown mode if the WDT2200 has been idle for the specified timeout period as set in AUTO OFF.

♦Shut Down In Shutdown mode, the main power is cut off from the WDT2200 excluding its RAM and Real Time Clock. NOTE: To conserve battery power, keep the WDT2200 in STAND BY mode while waiting for input. 3.2.3.6 Password Definition This function is used to create a password. The password is used to OLD PASSWORD: prevent an unauthorized user from entering the Supervisor mode and 2200 accidentally changing the WDT2200 configuration parameters. The NEW PASSWORD: Password may consist of maximum ten (10) alphanumeric characters ('A'-'Z', '0'-'9'). The Default password is “2200”. At the User Mode menu: 1. Press 6 (6.PSWD) 2. Enter the new password 3. Press [ENT] to change the Password

© 2003 Wasp Technologies, Inc.

Page 25

Page 25 of 41

3.2.3.7 Initialization The user can command the WDT2200 to execute a Cold Start that will clear all data stored in the RAM Disk and configure the terminal to default values.

Make sure your data has been backed up to a Host/PC before performing this function. At the Supervisor Mode menu: SELECT 7

Select 1

Select 2

When 1.COLD START is selected, press [1] for YES to confirm and execute a Cold Start, purge the RAM DISK and return to the Ready Mode menu. Press [0] for NO, abort Cold Start and return to User Mode Menu When 2.PROGRAMMING is selected, there is three items can be choose. This is one of the main feature provide by the WDT2200. User can select one of the program to add/erase user’s program saved in the FlashROM of the WDT2200, or updating the WDT2200 system BIOS firmware. 1. ADD PROGRAM the WDT2200 allows a user to store the application program into the FlashROM. The size of the FlashROM for the application program is 128KB. When ADD PROGRAM was selected, the WDT2200 will shows the available FlashROM free information on the screen. The user may save multiple application programs into the FlashROM if free space is still available. The user may move the application program from the RAM disk to the FlashROM and free up RAM disk for data storage. This feature will also prevent any application program lost due to any accidental system failure or cold start. 2. DELETE PROGRAM allows a user to delete all of the application programs stored in the FlashROM. The user will not be allowed to delete any single application program but the user can delete all the application programs stored in the FlashROM. User will need to confirm the program delete twice in case of any accidental input. 3. UPDATE BIOS, the WDT2200 allows the user to update or change the system BIOS in the field. Once UPDATE BIOS been selected, the WDT2200 will search for any update BIOS file in the RAM disk and then perform the update. If a BIOS file is not found, the WDT2200 will wait for the file to be downloaded from the communication port. After the upgrade is completed, the WDT2200 will automatically execute a COLD START. When this function has been chosen, you will see the following windows:

© 2003 Wasp Technologies, Inc.

Page 26

Page 26 of 41 Erase all data In RAM & FLASH ! Continue ? (YES/NO)

Select YES

< PROGRAMMING > Are you sure ? 1=YES/0=NO

If BIOS file found Select 1

< PROGRAMMING > Change BIOS to V.5.X 1=YES/0=NO

Select NO

<SYSTEM INITIAL> 1.COLD START 2.PROGRAMMING

Select 1

< PROGRAMMING > Please download BIOS file … If BIOS file not found

WARNING

: Before doing any system initialization, please make sure that you have already backed up / uploaded all data files stored in the WDT2200 to your Host/PC.

3.2.3.8

Diagnostics

1. The WDT2200 has a built-in diagnostics program to test the terminal's hardware. The test routines are data destructive. Therefore, before running the diagnostic program, make sure you back up the data in the WDT2200.

When a H/W or S/W service has been made on the WDT2200, such as maintenance, repair or upgrade, it is strongly recommended to run the diagnostic program. Diagnostic menu

At the Supervisor Mode menu:

0.All 1.RAM 2.KEY 3.232 4.LCD 5.RTC 6.SCANNER 7.RAM BCAKUP 8.EXIT

1. Press 8 (8.DIAG) 2. The LCD will display the diagnostic menu as shown on the left 3. Select 0-8 to run the desired diagnostic routine

SELECT (0-8)?_

0. All

Run all diagnostic routines from 1 to 8 shown below.

1. RAM

Fixed pattern stuck at fault check (00, FF, 55, AA). Address test: write odd, even address data into corresponding memory location, and verify it.

2. KEY

The LCD shows the legend of a key as it is pressed. Press [CMD], then [1] to return to the diagnostic menu.

3. 232

Loop back the WDT2200 RS232 port by connecting TxD and RxD pins together. All communication parameters are set to default values except baud rate is set to 57600 bps. The status of the tests is shown on the LCD. Darken the dots of the LCD screen and cycle power to the LCD backlight to check if the LCD functions OK.

4. LCD

© 2003 Wasp Technologies, Inc.

Page 27

Page 27 of 41 5. RTC

Current time/date is displayed. Verify. Press any key to return to the diagnostics menu.

6. SCANNER

Connect a bar code scanner to test bar code input by scanning bar code labels. Press any key to return to the diagnostics menu.

7. RAM BACKUP

Follow the instruction displayed on the LCD to press the [PWR] key to turn the power off and on to verify the memory backup.

8. EXIT

Return to the Ready mode of operation.