Manual · Wasp
CCD Programming Guide
Manual41 pagesPDF 617 KB
Programming guide for the Wasp CCD keyboard wedge bar code scanner: installation, quick start and configuration bar codes.
Filed with · 1 model
Also filed with these models on the old site
Summary
What is in it
The programming guide for the Wasp CCD hand-held bar code scanner, a contact keyboard wedge reader that needs no software or drivers. It explains installation between the PC and keyboard, the supported symbologies, and the Begin, setting and End bar code method used to change settings: defaults, terminator, preamble and postamble, buzzer and delay, keyboard type and language, scanning control, individual symbologies, interface options and serial port settings. Appendices hold test symbols and lookup tables.
Its parts
- Introduction
- Installation
- Quick Start
- Bar Code Symbologies
- CCD Setup & Configuration
From the manual · read page by page
Key facts from this manual
Each line names its page in the PDF.
The programming guide for the Wasp CCD Scanner, a hand-held keyboard wedge bar code reader; the guide calls it only the Wasp CCD and never names the UF-101. It holds the programming bar codes for restoring defaults, prefixes and suffixes, trigger modes, symbologies, keyboard type and language, and the optional RS-232 settings.
- Type
- Hand-held CCD bar code reader with a trigger and no moving parts p. 4
- Interface
- Keyboard wedge for PC AT/XT and PS/2 keyboards, needing no software or drivers; RS-232 is a special option p. 1, 4, 31
- Keyboard types
- PC AT, PS/2 50 60 70 80; PC XT; PS/2 25 30; Macintosh p. 14
- Reading range
- Depth of reading up to 1.4 inches; bar codes up to 3.15 inches long p. 4
- Scan rate
- 50 scans per second p. 4
- Minimum X-dimension
- 5 mils (0.005 in./0.127 mm) p. 7
- Symbologies
- Code 39, Code 128, Interleaved 2 of 5, UPC-A, UPC-E, EAN/JAN-8, EAN/JAN-13, Codabar, MSI Plessey, Code 93 p. 7
- Enabled by default
- Code 39, Codabar, Code 128, UPC-A, UPC-E, EAN/JAN 13, EAN/JAN 8; Interleaved 2 of 5, MSI/Plessey and 2 and 5 digit supplements are off p. 34, 35, 36
- Cables
- Keyboard wedge Y-cable with DIN 5 ends, plus Din 5 to Din 6 converter cables p. 5
- Serial option
- Baud rates 150 to 19200 (9600 default); 7 or 8 data bits; none, even or odd parity; Xon/Xoff or RTS/CTS flow control p. 32, 33
- Scan modes
- Trigger pressed; trigger with 3 second delay (default); on/off trigger with 3, 30 or 120 second delay; auto scan; continuous scan p. 16, 17, 18
- Keyboard languages
- US, French, German, Spanish, Swiss, UK p. 30
- Prefix and suffix
- Up to 7 characters each p. 11
- Settings memory
- Non-volatile; settings stay when the PC is turned off p. 8
What this manual walks you through
- Connecting the keyboard wedge cable between the PC and keyboard p. 5
- Programming a setting with the Begin, setting and End bar codes p. 8
- Restoring the factory default settings p. 1, 9
- Adding prefix and suffix characters to scanned data p. 11, 39, 40
- Setting buzzer volume, buzzer duration and intercharacter delay p. 12, 13
- Choosing trigger, auto scan and continuous scan modes p. 16, 17, 18
- Enabling symbologies and setting code identifier characters p. 19, 20
- Setting check digits, start and stop characters and fixed lengths per symbology p. 21, 22, 23, 24, 25, 26, 27, 28
- Setting the serial port baud rate, data bits, parity and flow control p. 32, 33
- Practicing with the bar code test symbols p. 34, 35, 36
Good to know
- The scanner does not work properly when plugged into the mouse port. p. 5
- RS-232 is a special option obtained through Wasp product support. p. 31
- If characters go missing, set the intercharacter delay to Fast; if stray characters appear, set it to Slow. p. 12
- With Number Lock set, digits pass only while the keyboard's Num Lock is on. p. 15
- Auto Scan will not read the same bar code twice in a row; Continuous Scan will. p. 18
Questions this manual answers
How do I reset the Wasp CCD scanner to factory settings?
Scan the default bar code on the Set Default page; it restores the factory settings. p. 1, 9
Does the Wasp CCD scanner need drivers?
No. It needs no software or drivers and enters data as keyboard data. p. 1
How far away can the Wasp CCD scanner read a bar code?
Up to 1.4 inches, and it reads bar codes up to 3.15 inches long. p. 4
Which bar codes are enabled by default on the Wasp CCD?
Code 39, Codabar, Code 128, UPC-A, UPC-E, EAN/JAN 13 and EAN/JAN 8; Interleaved 2 of 5, MSI/Plessey and the supplements are disabled. p. 34, 35, 36
Can the Wasp CCD scanner connect by RS-232?
RS-232 is a special option obtained through Wasp product support; the keyboard wedge is the default interface. p. 31
The whole text · 5 parts
Read the manual here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
The file