Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact
Page 1 of CCD Programming Guide

Manual · Wasp

CCD Programming Guide

Manual41 pagesPDF 617 KB

Programming guide for the Wasp CCD keyboard wedge bar code scanner: installation, quick start and configuration bar codes.

Download the PDF617 KB

Filed with · 1 model

Also filed with these models on the old site

Summary

What is in it

The programming guide for the Wasp CCD hand-held bar code scanner, a contact keyboard wedge reader that needs no software or drivers. It explains installation between the PC and keyboard, the supported symbologies, and the Begin, setting and End bar code method used to change settings: defaults, terminator, preamble and postamble, buzzer and delay, keyboard type and language, scanning control, individual symbologies, interface options and serial port settings. Appendices hold test symbols and lookup tables.

Its parts

  1. Introduction
  2. Installation
  3. Quick Start
  4. Bar Code Symbologies
  5. CCD Setup & Configuration

From the manual · read page by page

Key facts from this manual

Each line names its page in the PDF.

The programming guide for the Wasp CCD Scanner, a hand-held keyboard wedge bar code reader; the guide calls it only the Wasp CCD and never names the UF-101. It holds the programming bar codes for restoring defaults, prefixes and suffixes, trigger modes, symbologies, keyboard type and language, and the optional RS-232 settings.

Type
Hand-held CCD bar code reader with a trigger and no moving parts p. 4
Interface
Keyboard wedge for PC AT/XT and PS/2 keyboards, needing no software or drivers; RS-232 is a special option p. 1, 4, 31
Keyboard types
PC AT, PS/2 50 60 70 80; PC XT; PS/2 25 30; Macintosh p. 14
Reading range
Depth of reading up to 1.4 inches; bar codes up to 3.15 inches long p. 4
Scan rate
50 scans per second p. 4
Minimum X-dimension
5 mils (0.005 in./0.127 mm) p. 7
Symbologies
Code 39, Code 128, Interleaved 2 of 5, UPC-A, UPC-E, EAN/JAN-8, EAN/JAN-13, Codabar, MSI Plessey, Code 93 p. 7
Enabled by default
Code 39, Codabar, Code 128, UPC-A, UPC-E, EAN/JAN 13, EAN/JAN 8; Interleaved 2 of 5, MSI/Plessey and 2 and 5 digit supplements are off p. 34, 35, 36
Cables
Keyboard wedge Y-cable with DIN 5 ends, plus Din 5 to Din 6 converter cables p. 5
Serial option
Baud rates 150 to 19200 (9600 default); 7 or 8 data bits; none, even or odd parity; Xon/Xoff or RTS/CTS flow control p. 32, 33
Scan modes
Trigger pressed; trigger with 3 second delay (default); on/off trigger with 3, 30 or 120 second delay; auto scan; continuous scan p. 16, 17, 18
Keyboard languages
US, French, German, Spanish, Swiss, UK p. 30
Prefix and suffix
Up to 7 characters each p. 11
Settings memory
Non-volatile; settings stay when the PC is turned off p. 8

What this manual walks you through

  • Connecting the keyboard wedge cable between the PC and keyboard p. 5
  • Programming a setting with the Begin, setting and End bar codes p. 8
  • Restoring the factory default settings p. 1, 9
  • Adding prefix and suffix characters to scanned data p. 11, 39, 40
  • Setting buzzer volume, buzzer duration and intercharacter delay p. 12, 13
  • Choosing trigger, auto scan and continuous scan modes p. 16, 17, 18
  • Enabling symbologies and setting code identifier characters p. 19, 20
  • Setting check digits, start and stop characters and fixed lengths per symbology p. 21, 22, 23, 24, 25, 26, 27, 28
  • Setting the serial port baud rate, data bits, parity and flow control p. 32, 33
  • Practicing with the bar code test symbols p. 34, 35, 36

Good to know

  • The scanner does not work properly when plugged into the mouse port. p. 5
  • RS-232 is a special option obtained through Wasp product support. p. 31
  • If characters go missing, set the intercharacter delay to Fast; if stray characters appear, set it to Slow. p. 12
  • With Number Lock set, digits pass only while the keyboard's Num Lock is on. p. 15
  • Auto Scan will not read the same bar code twice in a row; Continuous Scan will. p. 18

Questions this manual answers

How do I reset the Wasp CCD scanner to factory settings?

Scan the default bar code on the Set Default page; it restores the factory settings. p. 1, 9

Does the Wasp CCD scanner need drivers?

No. It needs no software or drivers and enters data as keyboard data. p. 1

How far away can the Wasp CCD scanner read a bar code?

Up to 1.4 inches, and it reads bar codes up to 3.15 inches long. p. 4

Which bar codes are enabled by default on the Wasp CCD?

Code 39, Codabar, Code 128, UPC-A, UPC-E, EAN/JAN 13 and EAN/JAN 8; Interleaved 2 of 5, MSI/Plessey and the supplements are disabled. p. 34, 35, 36

Can the Wasp CCD scanner connect by RS-232?

RS-232 is a special option obtained through Wasp product support; the keyboard wedge is the default interface. p. 31

The whole text · 5 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 91-9
  2. Pages 10 to 1810-18
  3. Pages 19 to 2719-27
  4. Pages 28 to 3628-36
  5. Pages 37 to 4137-41

The file

Revision and size

RevisionRev H
PublisherWasp Technologies
Pages41
PDF617 KB
TextText from the PDF itself; page 38 is a scan, read by OCR, which may hold reading errors.

The first pages · 3 of 41

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 41
Page 2
Page 2of 41
Page 3
Page 3of 41

More documents · 1