Filed in the catalog under the Wasp UF-101

Page 10

CCD Setup & Configuration, Terminator Configuration

The 'Terminator' configuration is used to specify the end-of-text message. The terminator character is the last character sent to the keyboard buffer and comes after the Postamble characters if they are configured. It is primarily used to denote the end of the bar code value. Tip: If you need another character that is not listed as one of the terminator characters, you can use the 'Postamble' Configuration to add a suffix character or string.

Begin None

Carriage Return

*

Space

Escape

End *Default

7

Page 11

CCD Setup & Configuration, Preamble/Postamble Configuration

The 'Preamble/Postamble' configuration is used to add a prefix or suffix set of characters to the bar code value. Up to 7 characters may be added for each option separately. Preamble and postamble characters can function concurrently, but need to be configured separately. To add preamble or postamble characters, follow the steps below: (1) Scan the 'Begin' bar code on this page (2) Scan the 'Preamble' or 'Postamble' option (3) Use Appendix C on page 36 to locate the characters you want to add as preamble or postamble characters. Find the two character 'Code' associated with the character you want to add. Scan the two characters on page 35. Make sure that you scan the two bar codes associated with each letter before preceding to the next character. This step can be repeated up to six more times - seven total. For example, to add the letter "A," scan the "4," and then the "1" on page 35. The letter "A" will always appear in your data as a prefix or suffix to the bar code value. (4) Scan the 'Set' option on page 35. (5) Scan the 'End' bar code on this page.

Begin

Preamble Note: Please use Appendix C regarding the prefix string. You may add up to 7 characters as a Preamble.

Postamble Note: Please refer to Appendix C regarding the suffix string. You may add up to 7 characters as a Postamble.

End

8

Page 12

CCD Setup & Configuration, CCD Hardware Configuration:

The 'CCD Hardware' configuration supports the general control options for the CCD reader. These options include the buzzer volume, buzzer duration, and intercharacter delay. The intercharacter delay should be changed only if the transfer rate cannot be maintained between the CCD reader and the keyboard buffer of the computer. Note: The default for the intercharacter delay is set to 'Medium' and is the most common configuration; however, your PC may be different. When you scan a bar code, if some characters are missing, use the 'Fast' option to speed up the transfer rate. If some stray or scrambled characters appear at your cursor, use the 'Slow' option to slow down the transfer rate.

Begin

* Highest

High

Buzzer Volume Medium

Low

Lowest cont. on next page End

9

*Default

Page 13

CCD Setup & Configuration, CCD Hardware Configuration (cont.):

Begin

0.3 Seconds

Buzzer Duration * 0.1 Seconds

1 Second

* Medium

Fastest

Intercharacter Delay Fast

Slowest

Slow

End

10

*Default

Page 14

CCD Setup & Configuration, Keyboard Type Configuration

The 'Keyboard Type' configuration is used to program the reader for the type of computer it is attached to. This configuration is only used when the 'Interface Options' configuration is set to 'Keyboard'.

Begin

*PC AT, PS/2 50 60 70 80

PC XT

Keyboard Type

PS/2 25 30

Macintosh

End *Default

11

Page 15

CCD Setup & Configuration, Keyboard Setting Configuration

The 'Keyboard Setting' configuration provides specific options on how to pass your data to the keyboard buffer. 'Lower Case' is the default and toggles upper to lower case letters. For example, "A" is modified to "a". 'Upper Case' toggles lower to upper case letters. Either 'Lower Case' or 'Upper Case' can be enabled, but not both simultaneously. When 'Alphanumeric' is enabled all characters are passed unmodified. When 'Number Lock' is enabled, numbers that are in your bar coded values will be passed to the keyboard buffer if the "Num Lock" key is enabled on your keyboard. If the "Num Lock" key is disabled, numbers that are in your bar coded values will not be passed to the keyboard buffer of your computer.

Begin

*Lower Case

Upper/Lower Case Alphanumeric

Upper Case

*Alphanumeric

Alphanumeric/Number Lock

Number Lock

End *Default

12

Page 16

CCD Setup & Configuration, CCD Scanning Control Configuration

The 'CCD Scanning Control' configuration allows the user to customize how the trigger is to operate, the length of time in which the LEDs (i.e. the CCD photodetectors) are on, and activates auto scanning. The Wasp CCD has seven (7) options to control this configuration. Only one option can be enabled at a time. Note: When the LEDs are visible, the CCD scanner can read the bar code symbologies that are enabled. See 'Enable Bar Code Symbologies' for further information.

Begin

Trigger Pressed When this option is selected, the LEDs become visible when the trigger is pressed, and the LEDs will immediately go off when the trigger is released.

Trigger pressed

* Trigger with 3 Sec. Delay This is the default option for the Wasp CCD scanner. When this option is selected, the LEDs become visible when the trigger is pressed, and will remain on for three (3) seconds or until a bar code is scanned.

* Trigger with Delay

Tip: The delay option is a useful feature if you are scanning multiple bar codes back-to-back. 'Trigger with 3 Sec.Delay' is the default because it is the optimal configuration when you are setting up the Wasp CCD reader. Three bar codes are generally scanned for each step: 'Begin', an option, and 'End'. When this option is enabled, the trigger is typically only pressed one time to scan all three steps.

cont. on next page End

13

*Default

Page 17

CCD Setup & Configuration, CCD Scanning Control Configuration (cont.)

Begin

On/Off Trigger with 3 Second Delay When this option is selected, the LEDs become visible when the trigger is pressed, and will remain on for 3 seconds. The LEDs will turn off automatically after 3 seconds whether a bar code is successfully scanned or not or if the trigger is pressed again.

On/Off Trigger - 3 Second Delay

On/Off Trigger with 30 Second Delay When this option is selected, the LEDs become visible when the trigger is pressed, and will remain on for 30 seconds. The LEDs will turn off automatically after 30 seconds whether a bar code is successfully scanned or not or if the trigger is pressed again.

On/Off Trigger - 30 Second Delay

On/Off Trigger with 120 Second Delay When this option is selected, the LEDs become visible when the trigger is pressed, and will remain on for 120 seconds. The LEDs will turn off automatically after 120 seconds whether a bar code is successfully scanned or not or if the trigger is pressed again.

On/Off Trigger - 120 Second Delay cont. on next page End

14

*Default

Page 18

CCD Setup & Configuration, CCD Scanning Control Configuration (cont.)

Begin

Auto Scan When this option is enabled, the LEDs are always visible and the CCD reader will operate continuously without the need of using the trigger. In this mode, the CCD reader will not read identical bar code values back-to-back (i.e. one right after another).

Auto Scan

Continuous Scan When this option is enabled, the LEDs are always visible and the CCD reader will operate continuously without the need of using the trigger. This mode is very similar to the 'Auto Scan' mode with the exception that the CCD reader will read identical bar code values backto-back.

Continuous Scan

End *Default

15