Page 19

CCD Setup & Configuration, Enable Bar Code Symbologies Configuration

The 'Enable Bar Code Symbologies' configuration is used to enable or disable the various codes that the reader is able to decode. Multiple bar code symbologies can be enabled simultaneously.

Begin ON Code 39

OFF

*

Interleaved 2 of 5

*

Codabar

*

UPC-A EAN/JAN-13

*

EAN-8

*

UPC-E

*

EAN/UPC Add-on 2/5

Code 128

* *

MSI/Plessey

*

Code 93

*

End

16

*Default

Page 20

CCD Setup & Configuration, Code Identification Configuration

The 'Code Identification' configuration provides the option to precede each bar code symbology read with a character that identifies the type of symbology read. Only one code identifier is allowed for each specific type of bar code. These can be found in Appendix C on page 36. For example, to set the code identifier for Code 39 to be "A": (1) Scan the 'Begin' bar code on this page (2) Scan the 'Code 39' option (3) Turn to page 35 and scan the two bar codes associated with letter "A" (4) Scan the 'Set' option in Appendix C. (5) Scan the 'End' bar code on this page. In this example, each and every time a Code 39 bar code symbology is scanned, the letter "A" will precede the bar code value.

Begin Code 39 Interleaved 2 of 5 Codabar EAN-13/UPC-A EAN-8 UPC-E MSI/Plessey Code 128

End

17

*Default

Page 21

CCD Setup & Configuration, Code 39 Configuration

Code 39 is variable length and is the most frequently used symbology in industrial bar code systems today and is extensively used within the Department of Defense (DOD). The principal feature is to encode messages using the full alphanumeric character set. The Code 39 bar code uses four special characters "$", "/", "+". "%" which can be paired with alphanumeric characters to extend to the full ASCII character set. Standard Code 39 contains only 43 characters (0-9, A-Z, $, /, %, +, -, ., SPACE) and can be extended to a 128 character symbology (full ASCII) by combining one of the special characters ($, /, %, +) with a letter (A-Z) to form the characters that are not present in the standard Code 39 symbology.

Begin Off

On/Off On

*

Standard Type

*

Type Full ASCII

Transmit Start/Stop Character

No

*

Yes No

*

Verify Checksum Yes

Transmit Check Character

No Yes

*

End

18

*Default

Page 22

CCD Setup & Configuration, Code 128 Configuration

Code 128 is the most easily read bar code with the highest message integrity due to several separate message check routines. Of all the common linear symbologies, Code 128 is the most flexible. It supports both alpha and numeric characters, has the highest number of characters per inch, and is variable length. Code 128 is usually the best choice when implementing a new symbology. United Parcel Service (UPS) extensively uses this symbology.

Begin Off

On/Off On

*

End *Default

19

Page 23

CCD Setup & Configuration, MSI Plessey Configuration

MSI Plessey is a variable length numeric symbology primarily used in marking retail shelves. Each character consists of four bars with intervening spaces for each encoded digit, one or two symbol check digits, and a reverse start code.

Begin Off

*

On/Off On

End *Default

20

Page 24

CCD Setup & Configuration, Interleaved 2 of 5 Configuration

Interleaved 2 of 5 is a variable length, numeric bar code with an even number of digits. It is typically used in industrial and master carton labeling and also in the automotive industry. The symbology uses bars to represent the first character and the interleaved (white) spaces to represent the second character. The 'Interleaved 2 of 5' configuration provides the option to define up to three (3) fixed bar code lengths (i.e. number of characters). For example, to define the length of the bar code symbology, you must refer to Appendix B on page 34 and follow the steps below: (1) Scan the 'Begin' bar code on this page (2) Scan the 'Define Length' option (3) Use the lookup table (Appendix B) to find the value (0 - 255) and to define the bar code length. If, for example, the length is to be "10", the lookup value is "0A". Scan "0" first and then scan "A". This step can be repeated one to three times. (4) Scan the 'Set' option in Appendix B. (5) Scan 'End'.

Begin Off

*

On/Off On No

*

Transmit Check Digit Yes No

*

Verify Check Digit Yes

Define Length

End

21

*Default

Page 25

CCD Setup & Configuration, Codabar Configuration

Codabar is a variable length symbology capable of encoding up to 16 characters. Codabar can encode six special alphanumeric characters, capital letters A through D, T, N, *, E, and all numeric digits. Codabar is one of the oldest bar code symbologies and is still used in some library applications. Codabar symbology is not recommended for any new applications.

Begin

Off

On/Off On

*

No

*

Transmit Start/End Yes

ABCD/ABCD

ABCD/TN*E

Start/End Transmit Type abcd/abcd

* abcd/tn*e

End

22

*Default

Page 26

CCD Setup & Configuration, UPC-A Configuration

UPC-A (Universal Product Code-A) is a fixed length symbology and is the most common bar code used for retail product labeling. It is seen in most grocery stores across the United States. The symbology encodes a 12-digit, numeric-only number. The first six digits are assigned by the Uniform Code Council (UCC) in Dayton, Ohio. The next five digits are assigned by the manufacturer, and the final digit is a modulo 10 check digit. The nominal height for the UPC-A bar code is one inch. The reduced size is 80% of the nominal size.

Begin

Off

On/Off On

*

No

*

Truncate Leading Digit Yes

No

*

Truncate Leading 0 Yes

No

Transmit Check Digit Yes

*

End

23

*Default

Page 27

CCD Setup & Configuration, UPC-E Configuration

UPC-E (Universal Product Code-E) is also a fixed length symbology and is a compressed six digit code used for marking small packages including magazines and paperback books. UPC-E symbols are UPC-A symbols that have been zero suppressed (i.e. consecutive zeros are not included in the symbol). The printed value of the UPC-E code is a twelve digit code. The nominal height for the UPC-E bar code is one inch. The reduced size is 80% of the nominal size.

Begin

Off

On/Off On

*

No

*

Truncate Leading Digit Yes

No

Transmit Check Digit Yes

*

End