Page 19
CCD Setup & Configuration, Enable Bar Code Symbologies Configuration
The 'Enable Bar Code Symbologies' configuration is used to enable or disable the various codes that the reader is able to decode. Multiple bar code symbologies can be enabled simultaneously.
Begin ON Code 39
OFF
*
Interleaved 2 of 5
*
Codabar
*
UPC-A EAN/JAN-13
*
EAN-8
*
UPC-E
*
EAN/UPC Add-on 2/5
Code 128
* *
MSI/Plessey
*
Code 93
*
End
16
*Default
Page 20
CCD Setup & Configuration, Code Identification Configuration
The 'Code Identification' configuration provides the option to precede each bar code symbology read with a character that identifies the type of symbology read. Only one code identifier is allowed for each specific type of bar code. These can be found in Appendix C on page 36. For example, to set the code identifier for Code 39 to be "A": (1) Scan the 'Begin' bar code on this page (2) Scan the 'Code 39' option (3) Turn to page 35 and scan the two bar codes associated with letter "A" (4) Scan the 'Set' option in Appendix C. (5) Scan the 'End' bar code on this page. In this example, each and every time a Code 39 bar code symbology is scanned, the letter "A" will precede the bar code value.
Begin Code 39 Interleaved 2 of 5 Codabar EAN-13/UPC-A EAN-8 UPC-E MSI/Plessey Code 128
End
17
*Default
Page 21
CCD Setup & Configuration, Code 39 Configuration
Code 39 is variable length and is the most frequently used symbology in industrial bar code systems today and is extensively used within the Department of Defense (DOD). The principal feature is to encode messages using the full alphanumeric character set. The Code 39 bar code uses four special characters "$", "/", "+". "%" which can be paired with alphanumeric characters to extend to the full ASCII character set. Standard Code 39 contains only 43 characters (0-9, A-Z, $, /, %, +, -, ., SPACE) and can be extended to a 128 character symbology (full ASCII) by combining one of the special characters ($, /, %, +) with a letter (A-Z) to form the characters that are not present in the standard Code 39 symbology.
Begin Off
On/Off On
*
Standard Type
*
Type Full ASCII
Transmit Start/Stop Character
No
*
Yes No
*
Verify Checksum Yes
Transmit Check Character
No Yes
*
End
18
*Default
Page 22
CCD Setup & Configuration, Code 128 Configuration
Code 128 is the most easily read bar code with the highest message integrity due to several separate message check routines. Of all the common linear symbologies, Code 128 is the most flexible. It supports both alpha and numeric characters, has the highest number of characters per inch, and is variable length. Code 128 is usually the best choice when implementing a new symbology. United Parcel Service (UPS) extensively uses this symbology.
Begin Off
On/Off On
*
End *Default
19
Page 23
CCD Setup & Configuration, MSI Plessey Configuration
MSI Plessey is a variable length numeric symbology primarily used in marking retail shelves. Each character consists of four bars with intervening spaces for each encoded digit, one or two symbol check digits, and a reverse start code.
Begin Off
*
On/Off On
End *Default
20
Page 24
CCD Setup & Configuration, Interleaved 2 of 5 Configuration
Interleaved 2 of 5 is a variable length, numeric bar code with an even number of digits. It is typically used in industrial and master carton labeling and also in the automotive industry. The symbology uses bars to represent the first character and the interleaved (white) spaces to represent the second character. The 'Interleaved 2 of 5' configuration provides the option to define up to three (3) fixed bar code lengths (i.e. number of characters). For example, to define the length of the bar code symbology, you must refer to Appendix B on page 34 and follow the steps below: (1) Scan the 'Begin' bar code on this page (2) Scan the 'Define Length' option (3) Use the lookup table (Appendix B) to find the value (0 - 255) and to define the bar code length. If, for example, the length is to be "10", the lookup value is "0A". Scan "0" first and then scan "A". This step can be repeated one to three times. (4) Scan the 'Set' option in Appendix B. (5) Scan 'End'.
Begin Off
*
On/Off On No
*
Transmit Check Digit Yes No
*
Verify Check Digit Yes
Define Length
End
21
*Default
Page 25
CCD Setup & Configuration, Codabar Configuration
Codabar is a variable length symbology capable of encoding up to 16 characters. Codabar can encode six special alphanumeric characters, capital letters A through D, T, N, *, E, and all numeric digits. Codabar is one of the oldest bar code symbologies and is still used in some library applications. Codabar symbology is not recommended for any new applications.
Begin
Off
On/Off On
*
No
*
Transmit Start/End Yes
ABCD/ABCD
ABCD/TN*E
Start/End Transmit Type abcd/abcd
* abcd/tn*e
End
22
*Default
Page 26
CCD Setup & Configuration, UPC-A Configuration
UPC-A (Universal Product Code-A) is a fixed length symbology and is the most common bar code used for retail product labeling. It is seen in most grocery stores across the United States. The symbology encodes a 12-digit, numeric-only number. The first six digits are assigned by the Uniform Code Council (UCC) in Dayton, Ohio. The next five digits are assigned by the manufacturer, and the final digit is a modulo 10 check digit. The nominal height for the UPC-A bar code is one inch. The reduced size is 80% of the nominal size.
Begin
Off
On/Off On
*
No
*
Truncate Leading Digit Yes
No
*
Truncate Leading 0 Yes
No
Transmit Check Digit Yes
*
End
23
*Default
Page 27
CCD Setup & Configuration, UPC-E Configuration
UPC-E (Universal Product Code-E) is also a fixed length symbology and is a compressed six digit code used for marking small packages including magazines and paperback books. UPC-E symbols are UPC-A symbols that have been zero suppressed (i.e. consecutive zeros are not included in the symbol). The printed value of the UPC-E code is a twelve digit code. The nominal height for the UPC-E bar code is one inch. The reduced size is 80% of the nominal size.
Begin
Off
On/Off On
*
No
*
Truncate Leading Digit Yes
No
Transmit Check Digit Yes
*
End
24
*Default