Once the transfer is complete, the data is processed and stored in an ASCII text file. The first 10K of the ASCII text file is displayed in the Data Transfer Window. You may use the arrow keys to scroll through and view the data. Press the <Esc> key to leave the Data Transfer Window and return the cursor to the Wand Transfer Status box. At that time, the transfer status of the wands is updated. Press <Esc> again to return to the Main Menu screen. The raw scan file is appended to a file called HIST.BCD, which is a history file of all scan data transferred from TimeWand IIs. The HIST.BCD file provides a back-up copy or history of all of the data transferred to the computer. This file needs to be managed because, in the process of appending data each time TimeWand IIs are transferred, the file can grow quite large.

Chapter 2 TimeWand II Application Builder Reference

67

Page 72

The following flow chart diagram illustrates how TimeWand II Communications & Application Builder handles the TimeWand II data files during the transfer process.

TWII DATA FILE HANDLING TimeWand II data is transferred into:

TEMP.UNL

Temporary file for wand data. Deleted automatically after each wand is transferred.

APPEND HIST.BCD

DOWNLOAD.DBF

CONVERT ROUTINE

DATA.BCD

History file of all scan data as it came out of the TWII(s).

Temporary file used by Clipper® to process the scan data.

Runs after all wands have been transferred. (A stand-alone version of the convert routine called CONVERT2.EXE can also be run from the DOS prompt.)

Same as TWI DATA.TXT raw scan file.

Formatted text file for import into application programs.

Figure 2-7 TimeWand II Data File Handling

Quit The last choice on the Main Menu screen is Quit. It is very important that you quit the program properly before turning off or rebooting the computer. Terminating the computer abnormally can cause the loss or corruption of important program and data files. 68

Chapter 2 TimeWand II Application Builder Reference

Page 73

Chapter 3 Building TimeWand II Applications Applications TimeWand II applications provide additional control over the data collection process. The primary purpose of an application is to collect data and create a data file with the collected data. What distinguishes one application from another is the way it collects data. When creating an application, there needs to be something unique about the bar codes or entry for each step; this allows the TimeWand II to know that the criterion has been met to advance to the next step. TimeWand II applications are software files that contain instructions for a wand. A TimeWand II application can be loaded into a wand that is programmed with an operating system symbology program. The application file works in conjunction with the operating system symbology program and allows control of the display prompts and sequence of data entry. Cross-reference files, such as part numbers and their descriptions, may be built into an application for easy validation of data input.

Chapter 3 TimeWand II Applications

69

Page 74

Building Applications Discussion Following is an explanation of the theory and principles behind a TimeWand II application. This explanation is intended to give you a deeper understanding of applications and how to build them. An application consists of a set of “fields” arranged in a hierarchy. Fields in a hierarchy are best explained with an example. If you were building an inventory application to count the items contained in bins at different warehouses, you could build this application using four fields: Warehouse, Bin #, Item #, and Quantity. We want the user to first scan a bar code representing the Warehouse, then the Bin #, then the Item #, then the Quantity. If there are multiple items in the bin, you want the user to scan Item # and Quantity repeatedly for each item in the bin. When the user completes a bin, you want them to scan the next Bin #, then the Item #s in that bin and their Quantities. When the user completes a warehouse, you want them to scan the next warehouse, its bins, items, and quantities, and so on. In order to get good data, you want the user to scan the fields in their proper sequence. For instance, you do not want the user to scan an Item # without first scanning a preceding Warehouse or Bin #. Also, you do not want the user to scan a Bin #, then scan a Quantity without identifying the Item #. Fields in a TimeWand II application follow a set of hierarchical rules which require the user to scan items in their proper sequence. These rules are explained below. Each field is assigned a level number. Level numbers start with 1.00. These level numbers determine in what sequence the fields are scanned. Several fields may be assigned to the same level by using the tenths and hundredths of the level number.

70

Chapter 3 TimeWand II Applications

Page 75

The user is required to begin by scanning the first field on level 1. All of the fields on the level must be scanned. After all of the fields on the level have been scanned, the user can scan the first field on the next level, or scan the first field on any of the previous levels. For example, after scanning down to the bottom of level 3:

1.0 field 1.1 field 1.2 field 2.0 field 3.0 field 3.1 field 3.2 field 3.3 field 4.0 field 4.1 field 5.0 field 5.1 field 5.2 field

Chapter 3 TimeWand II Applications

71

Page 76

The user could scan these fields:

1.0 field 1.1 field 1.2 field 2.0 field 3.0 field 3.1 field 3.2 field 3.3 field 4.0 field 4.1 field 5.0 field 5.1 field 5.2 field

Note: The user could not scan the field(s) on level 5 unless all of the fields on level 4 were scanned first, because the user cannot skip any levels while moving down the hierarchy. In the inventory example, INVENTRY.APX, we assign Warehouse a level number 1.0, Bin # a level number 2.0, Item # a level number 3.0, and Quantity a level number 3.1. This prevents scanning out of sequence because the hierarchy forces the user to start on level 1 and prevents any skipping of levels while going down the hierarchy. It also forces the user to scan or key in a Quantity for each Item #, because after an Item # is scanned (the first field on level 3), all of the fields on level 3 must be scanned.

72

Chapter 3 TimeWand II Applications

Page 77

The application screen for the INVENTRY.APX application looks like this:

Figure 3-1 INVENTRY.APX Application Screen The application, once entered into the Create/Edit Application screen, must be “compiled” into a form that the TimeWand II can understand. Compiled applications are stored in files with a .APX extension. To compile an application, press the <F6> key. When the application is compiled and loaded into the TimeWand II, each field name appears on the first line of the display as a prompt. INVENTRY.APX has already been created and compiled and is included with the software.

Chapter 3 TimeWand II Applications

73

Page 78

Below are Code 3 of 9 bar codes for this application. Once you have learned how to program your TimeWand II, you may wish to program the TimeWand II with INVENTRY.APX and scan these bar codes to get a feel for how applications work. Warehouse:

Bin #:

*C82* *TR237*

Item #:

*E0002*

After scanning the Item #, pressing the scan button prompts you to scan the quantity. Use the numeric keys (followed by the = key) on the TimeWand II to enter a quantity. Now scan: Bin #:

*TR248*

Item #:

*E0003*

Use the numeric keys (followed by the = key) on the TimeWand II to enter a quantity.

74

Chapter 3 TimeWand II Applications

Page 79

Now scan: Warehouse:

Bin #:

Item #:

*C94* *TR237* *E0012*

Use the numeric keys (followed by the = key) on the TimeWand II to enter a quantity. You may also wish to scan a few bar codes out of sequence to see how the application reacts. For instance, scan Warehouse, then Item #. You will see that you are unable to skip any levels while going down the hierarchy. Again, the <Esc> key takes you from the Create/Edit Application screen to the Wand Set Up screen. The TimeWand II Communications & Application Builder for DOS software includes three complete applications: INVENTRY.APX, RETAIL.APX, and STANDARD.APX. The following sections describe each application. Appendix J contains sample bar codes that can be used with these applications.

Chapter 3 TimeWand II Applications

75

Page 80

INVENTRY.APX Application The INVENTRY.APX application (Figure 3-2) is a four-field inventory application that records the warehouse, the bin number, the item number, and the quantity of items. This type of application is useful for inventory applications of almost any type; it can also be customized to keep track of items going to various locations, to locate items, and so on.

Figure 3-2 INVENTRY.APX Application The INVENTRY.APX application requires the following: 1. A warehouse entry must be entered first; the entry must begin with a C. This field belongs to Level 1. 2. A Bin# entry must be entered next; the entry must be two alpha characters followed by three numeric characters. This field belongs to Level 2. 3. An Item# entry for an item in the bin must be entered; the entry must be contained in the PART.XRF cross-reference file. This field belongs to level 3. 4. And the quantity of items must be entered; the quantity entry must be composed of numeric characters. This field also belongs to level 3.

76

Chapter 3 TimeWand II Applications