Page 81

The Item# and the quantity both belong to level 3; this means that when an Item# entry is made, a quantity entry must follow.

Chapter 3 TimeWand II Applications

77

Page 82

RETAIL.APX Application The RETAIL.APX application (Figure 3-3) is a three-field application that records the customer, the part code, and the quantity of parts. This type of application is useful for recording transactions of almost any type; it can be customized to ship items, record orders, inventory, storage locations, and so on.

Figure 3-3 RETAIL.APX Application The RETAIL.APX application requires the following: 1. A CUSTOMER entry must be entered first; the entry must begin with an C. This field belongs to Level 1. 2. An ITEM entry must be entered; the entry must be contained in the GOOD.XRF cross-reference file. This field belongs to level 2. 3. And the QUANTITY of each item must be entered; the quantity entry must be composed of numeric characters. This field also belongs to Level 2. The ITEM and QUANTITY fields both belong to level 2; this means that if an ITEM entry is made, a QUANTITY entry must follow. 78

Chapter 3 TimeWand II Applications

Page 83

STANDARD.APX Application The standard application (Figure 3-4) is a one-field application that accepts any data. This type of application is useful when strict control of data entry is not required.

Figure 3-4 Standard Application - Edit Application Screen The standard application will accept any entry; it has no special requirements.

Chapter 3 TimeWand II Applications

79

Page 84

Building Applications Discussion The two screens used to edit and build applications are the Wand Set Up screen and the Create/Edit Application screen. The Wand Set Up screen has an application window that lists the current applications. To edit an application, press <F7> and the application will be displayed in the Create/Edit Application screen. To create a new application, press <F9> and the software will step you through building a new application. The Wand Set Up screen and the Create/Edit Application screen are discussed in detail in the following sections on pages 76–86. Beginning on page 87 is a section that steps you through building a sample application.

80

Chapter 3 TimeWand II Applications

Page 85

Wand Set Up Screen The Wand Set Up screen (Figure 3-5) contains the Wand ID, Symbology, and Application windows.

Figure 3-5 Wand Set Up Screen

Wand ID Window The Wand ID window maintains the list of wand IDs. A wand ID is a unique name or number assigned to a TimeWand II. The default ID is displayed at the top of the window. This ID appears as the default when programming the TimeWand II. To change the default, use the arrow keys to highlight the desired ID and then press <F10>. To add an ID, press the <F9> key. To delete an ID, highlight the ID and press <F8>. The default ID cannot be deleted.

Chapter 3 TimeWand II Applications

81

Page 86

Symbology Window The Symbology window lists the current TimeWand II operating system symbology program. The TimeWand II must be programmed with its operating system symbology program before it can read bar codes.

Application Window The Application window lists the existing applications. The default application is shown at the top of the window. To change the default, highlight the application of your choice and press <F10>. If you wish to program a TimeWand II without an application, set the default to “None” by pressing <F6>. To edit an existing application, highlight the application and press the <F7> key. The software asks you to verify that you want to edit the file. Press <Enter>, and the Create/Edit Application screen for the application appears. To delete an application, highlight the application and press the <F8> key. Deleting an application erases the files for that application from the disk.

Warning! Deleting an application erases all of the files for that application from the hard disk. Use the delete function with caution.

To create a new application, press the <F9> key and enter the name for the application. The Create/Edit Application screen appears. The Create/Edit Application screen and building an application are explained in the following sections.

82

Chapter 3 TimeWand II Applications

Page 87

Create/Edit Application Screen The Create/Edit Application screen (Figure 3-6) is where applications are created and edited. You can create an application to control the sequence of the entries and to control the prompts that appear on the wand’s display.

Figure 3-6 Create/Edit Application Screen The first step in creating an application is to add the fields. To add a field, press the <F9> key. You are then prompted to enter the field name. The field name may be any alphanumeric combination up to 16 characters in length. The field name will be used as the prompt on the TimeWand II display for that field. After adding a field name, it is necessary to specify the level number for that field. The level number determines the sequence in which the fields are scanned. To specify a field’s level number, use the arrow keys to highlight the Level Number for that field, press <Enter>, type the level number, and press <Enter> again. The <F10> key sorts the fields according to their level numbers. When the TimeWand II reads a bar code, it must be able to discern which field of the application the bar code belongs to; Chapter 3 TimeWand II Applications

83

Page 88

this is the purpose of the Match Criteria column. The TimeWand II compares the entry with the match criteria specified for each field. The menu choices which appear when specifying the match criteria help you build the pattern(s) you need. The use of those menus can be mastered with experimentation. The match criteria may consist of either a pattern of letters and/or numbers, or a list of bar codes in a cross-reference (.XRF) file. When specifying the matching criteria, the “X-REF File” menu choice enables you to specify a cross-reference file as the matching criteria. The Default column lists the default entry for the field. Note: The first field in a level cannot have a default. The <F6> key compiles the application. Each application must be compiled before it can be loaded into the TimeWand II. Before an application is compiled, it exists only as ASCII text which you can see on your computer screen. When it is compiled, it is translated into a Hex format that the TimeWand II can understand. Compiled applications are stored in files that have a .APX extension. If there are any errors in the compilation process, they appear in the Compile Application window. All errors must be corrected before the application can be compiled successfully and loaded into the TimeWand II. The <F8> key deletes a field. Highlight the field you wish to delete and press <F8>. The <F5> key is merely a short-cut from the Create/Edit Application screen to the Program Wand section of the program. The <Esc> key takes you back to the Wand Set Up screen.

84

Chapter 3 TimeWand II Applications

Page 89

The following section describes the different columns in the Create/Edit Application screen.

LEVEL NUMBER Column This column lists the level number. The level number represents the order of data entry that is enforced when using the application. Level numbers start with 1.00. The level number determines in what order the fields are scanned. Several fields may be assigned to the same level by using the tenths and hundredths of the level number. If more than one field belongs to the same level number, then when data for the first field in the level is entered, data for all the other fields in the level must also be entered. Data must be entered consecutively for all fields in a particular level.

FIELD NAME Column This column lists the field names for the application. A field name can be up to 16 characters of text. The field name will serve as the prompt that appears on the wand’s display during each scan step.

MATCH CRITERIA Column This column lists the match criteria for the field. The match criteria can be a match pattern composed of standard characters, token characters, or a combination of both; the name of a cross-reference file; or no pattern (which accepts any entry). When an entry is made, the wand verifies that the data meets the specific criteria. The match criteria creates a filter for the data being entered during each scan step. The filter gives you greater control over the data collection process. When you enter the Match Criteria column and press <Enter>, you are given a choice of the match criteria listed in the following table: Chapter 3 TimeWand II Applications

85

Page 90

Match Criteria

Description

BEGINS WITH

User input must begin with the entered text.

LENGTH

User input must be the given number of characters long.

MATCH EXACTLY

User input must exactly match the entered text.

PATTERN

User input must match the match pattern. See pages 82–84 for information on TimeWand II match patterns.

X-REF FILE

User input must be contained in a cross-reference file.

NO PATTERN

User input can be any data.

The following sections describe the various Match Criteria.

BEGINS WITH If you choose BEGINS WITH for the match criteria, the software prompts you to enter the bar code’s starting character. The user input must begin with the character entered in the box.

LENGTH If you choose LENGTH for the match criteria, the software prompts you to enter the length of the bar code and whether the bar code is alphabetic, numeric, or alphanumeric. The length and type of the user input must equal the length and type entered. MATCH EXACTLY If you choose MATCH EXACTLY for the match criteria, the software prompts you to enter the exact match for the bar code entry. The user input must exactly match the entered text. 86

Chapter 3 TimeWand II Applications