For the Videx TimeWand II

Page 61

application setting is merely for your convenience. If you wish to program a TimeWand II without an application, set the default to “None” by pressing <F6>. To create a new application, press the <F9> key and enter the name for the application. The Create/Edit Application screen then appears. The Create/Edit Application screen and building an application are explained in detail in Chapter 3. To delete an application, highlight the application and press the <F8> key. Deleting an application erases the files for that application from the disk. (Note: You cannot delete an application if it is the default application. You must first change the default to another application before you can delete the application.)

Warning! Deleting an application erases all of the files for that application from the hard disk. Use the delete function with caution.

To edit an existing application, highlight the application and press the <F7> key. The Create/Edit Application screen for that application then appears.

Chapter 2 TimeWand II Application Builder Reference

57

Page 62

Computer Set Up Screen From the Wand Set Up screen, press <F2> to go to the Computer Set Up screen. The Computer Set Up screen (Figure 2-4) enables you to change the defaults for the computer’s communication settings. The Computer Set Up screen is divided into three windows. Use the left and right arrow keys to move the cursor through the three windows. (Note: The window’s contents do not appear on the screen until the cursor is moved into the window with the arrow keys.)

Figure 2-4 Computer Set Up Screen

Files Window The Files window specifies the destinations and names of the ASCII text files received from the TimeWand II. The path name for these files can be up to 21 characters in length. When transferring data from the TimeWand II, you specify the format of either a “raw scan file” or a “formatted text file.” The names and destinations of these data files are specified here. For more information on these data files, see the section on the Transfer Data Screen beginning on page 59.

58

Chapter 2 TimeWand II Application Builder Reference

Page 63

Baud Rate Window The Baud Rate window specifies the baud rate at which the computer and TimeWand II communicate. The software uses a default of 19200 baud. To change the default, use the arrow keys to highlight the desired baud rate and press <Enter>. Note: The TimeWand II’s baud rate is set when the wand is programmed. After programming, all communication with the TimeWand II must occur at the same baud rate.

Com Port Window The Com Port window specifies the default serial (Com) port that is used to communicate with the TimeWand II. The software uses COM1 by default. To change the default to COM2, use the arrow keys to highlight COM2 and press <Enter>. Only COM1 and COM2 are supported.

Program Wand Screen The TimeWand II must be programmed before it can read bar codes. It is just like a computer, in that it must have a program within it to tell it what to do. The files needed to program a TimeWand II are stored on the computer’s hard disk. Programming the wand means loading the TimeWand II with the information it needs to operate properly. This information includes the wand ID, the symbology program, and the application that controls the prompts and the sequence of the bar codes. Programming the TimeWand II involves two steps: initializing the TimeWand II and loading it with an application.

Chapter 2 TimeWand II Application Builder Reference

59

Page 64

Initialization involves resetting the TimeWand II, and then loading it with a symbology file and a wand ID. Initializing a TimeWand II is like formatting a floppy disk: it must be done before the wand can store data and it only needs to be done once (unless you change the operating system symbology program). Any data stored in a programmed wand is lost if the wand is reprogrammed before the data is transferred. A TimeWand II, once initialized, can read and store bar codes and then transfer them to the computer. The TimeWand II’s only prompt is “Please scan” and the bar codes are accepted in any sequence. Once programmed with an application, the TimeWand II displays prompts and accepts bar codes as directed by the application. For information on creating an application, refer to the Building Applications section beginning on page 75. When programming the TimeWand II, certain defaults are available. The factory settings for these defaults are: WAND SET UP: Wand ID = VIDEX Symbology = TW2OS303.SYM Application = STANDARD.APX COMPUTER SET UP: Raw Scan File = DATA.BCD Formatted Text File = DATA.TXT Baud Rate = 19200 Serial Port = COM1 These defaults can be changed in the Set Up screens.

60

Chapter 2 TimeWand II Application Builder Reference

Page 65

The Program Wand screen (shown in Figure 2-5) is accessed from the Main Menu screen.

Figure 2-5 Program Wand Screen The screen area entitled “Wand Programming Status” lists the following information for each wand ID: date and time of last programming, the status as to whether the wand was successfully programmed, and the symbology, application, and baud rate with which the wand was programmed. Inside the “Wand Programming Status” area, there is a cursor which can be moved around with the arrow keys. It is not necessary to use the cursor to highlight the wand ID you wish to program. The cursor is there merely to give you the ability to scroll the list inside the box if the list of IDs gets too long for it to be seen at one time. To initialize a TimeWand II, press <F5>. A box with the default settings for Wand ID, Symbology, and Application appears. These settings may be changed by highlighting one of them and pressing <Enter>. Another window with choices for that setting appears. Use the arrow keys to highlight your choice and press <Enter>. The default setting is temporarily changed to the setting you specify.

Chapter 2 TimeWand II Application Builder Reference

61

Page 66

When you are satisfied with the communications settings, press <F5> to proceed with the initialization of the TimeWand II. You are prompted to reset the TimeWand II, insert it into the recharger/downloader, and press any key on the computer keyboard. When initializing a TimeWand II, it is VITAL that you have only one TimeWand II inserted into the recharger/downloader at a time. The computer tries for 20 or 30 seconds to communicate with the TimeWand II. Once communication has been established between the wand and the computer, the initialization process begins and the TimeWand II displays “Loading...”. The TimeWand II then flashes “SYM loaded” and/or “APX loaded” followed by the charge status when the initialization process is completed. After the wand is initialized, the Wand Programming Status box on the screen is updated. The <F4> key enables you to load an application or change the application that is loaded in a previously initialized TimeWand II. When you press <F4>, a window appears warning you that any data in the wand will be lost when the application is loaded. If there is any data in the TimeWand II, transfer it to the computer before you load the new application. The ID and Application settings can be changed by highlighting the parameter and pressing <Enter>. Another window displaying choices for that parameter appears. Highlight your choice and press <Enter> to select it. Press <F4> to proceed with the loading of the designated application. After the application is loaded, the Wand Programming Status is updated.

62

Chapter 2 TimeWand II Application Builder Reference

Page 67

Transfer Data Screen Bar code data stored in the TimeWand II is transferred to the computer through the serial port and stored in an ASCII file on the computer’s hard disk. When transferring data from the TimeWand II, certain defaults are available. The factory settings for these defaults are: COMPUTER SET UP: Raw Scan File = DATA.BCD Formatted Text File = DATA.TXT Baud Rate = 19200 Serial Port = COM1 The Raw Scan File and Formatted Text File parameters refer to the names of the ASCII text files in which the data is stored when it is transferred from the TimeWand II. These defaults can be changed in the Computer Set Up screen. The Transfer Data screen is accessed from the Main Menu screen. The Transfer Data screen is shown in Figure 2-6.

Figure 2-6 Transfer Data Screen

Chapter 2 TimeWand II Application Builder Reference

63

Page 68

At the left side of the screen is a table entitled “Wand Transfer Status.” The table shows transfer information for each wand ID (the date and time of the last transfer and the number of scans transferred). There is a cursor which can be moved around inside the box using the arrow keys. It is not necessary to use the cursor to highlight the wand ID from which you wish to transfer data. The cursor is there merely to give you the ability to scroll through the list inside the box if the list gets too long for it to be seen at one time. The box on the right side of the screen, entitled “Data Transfer Window,” displays the ASCII text file of data transferred from the TimeWand II. (The Data Transfer Window only displays the first 10K of the file). Press <F4> to see the text file that contains data from the last transfer. To transfer data, insert the TimeWand II into the recharger/ downloader. Press the scan button to “wake up” the wand. (The wand automatically wakes up by itself within 60 seconds if you do not press a button.) After awakening, the TimeWand II display flashes “Power Connected” followed by the charge status. Press the <F5> key, and a menu box appears at the lower-right portion of the screen. By using the arrow keys, you may move the cursor between the two menu choices: “Scan data” and “Output file.”

64

Chapter 2 TimeWand II Application Builder Reference

Page 69

Highlight the “Scan data” choice and press <Enter>. By using the arrow keys, you may move the cursor between the two choices for scan data: “Append scans” and “Erase previous scans.” These choices refer to the data that was previously transferred and stored on the hard disk. When data is transferred from the wand to the computer, it is stored in an ASCII text file. (The file’s name and path are specified under the Computer Set Up screen.) Subsequently, when new data is transferred, some decision must be made whether the new data should be appended onto the end of the existing text file, or whether the new data should overwrite (and erase) the existing file. Highlight your preference and press <Enter> to select it. Highlight the “Output file” choice and press <Enter>. Using the arrow keys, you can move the cursor between the two choices: “Raw scan file” and “Formatted text file.” Selecting “Raw scan file” produces an ASCII text file with the following format: H 19970905110839 00 VIDEX 19970905102552 00 C23 19970905102552 00 TW008 19970905102552 00 KC44 19970905102553 00 55 19970905102553 00 KC77 19970905102553 00 61 19970905102554 00 C28 19970905102554 00 TW016 19970905102554 00 KC55 19970905102554 00 32 19970905102555 00 KC71 19970905102555 00 110 19970905102556 00 KC7 19970905102556 00 58 T 000 A further explanation of the “Raw scan file” format can be found in Appendix C. Chapter 2 TimeWand II Application Builder Reference

65

Page 70

To easily import your data into application software, you may wish to select “Formatted text file.” The formatted text file arranges your data in a tabular format, which allows easier import of your data into other programs. Highlight “Formatted text file” and press <Enter>. A menu box appears allowing you to define the parameters used to format the data: delimiter, quote marks, wand ID, and date and time stamp. Highlight the parameter you wish to change and press <Enter>. Another window with choices for that parameter appears. Highlight the choice you want and press <Enter> to select it. Press <Esc> when you are satisfied with the format. A comma-delimited formatted text file would look like this: C23, TW008, KC44, 55 C23, TW008, KC77, 61 C28, TW016, KC55, 32 C28, TW016, KC71, 110 C28, TW016, KC45, 69 C28, TW016, KC7, 58 C28, TW008, KC88, 62 C28, TW008, KC45, 151 Press <F5> again to transfer the data from the TimeWand II. If you have specified “Erase previous scans” you receive a warning message that the file containing the previous scans will be erased. Press <F5> again to proceed with the transfer. The program goes through the list of wand IDs, one at a time, trying to communicate with each one. When a connection with a TimeWand II is established, the program instructs the TimeWand II to transfer its data. After the transfer, the TimeWand II’s clock is set to match the computer’s clock, and the wand’s data is cleared. The computer continues to go through the list of wands for approximately 70 seconds, or until the <Esc> key is pressed, or until data has been transferred from all of the wands in the list. 66

Chapter 2 TimeWand II Application Builder Reference