Page 17

PulseStar PC Software - Tab Windows

Figure 10 - Configure Tab

Configure Tab This tab shows the list of PulseStars in your system, the name or serial number assigned to them, and the last date and time of communications. New PulseStars are automatically added to the list when they are encountered by the communications software. To assign a name or enter the serial number, simply type in the desired name. The transfer grid will automatically update to show the changes. Tab headings & buttons: Factory ID Unique ID of PulseStar Name or Serial Number - User defined name or serial number Last Communications Date and time of last communication

Page 14

Page 18

PulseStar PC Software - Tab Windows Delete button - Remove PulseStar from list. Advanced button - Brings up the list of settings to program into the PulseStar the next time it is encountered. When a PulseStar is new, it is configured to the four settings shown in Figure 11.

Figure 11 - Advanced Configurations

Duration of “good read” pulse – This tells the PulseStar how long to run its motor to indicate that an iButton has been read and recorded. The factory default is 1000 milliseconds (1 second). Since the “good read” pulse is the largest current draw in the system, increasing this value could significantly reduce battery life. Conversely, decreasing the duration could improve battery life, particularly if reading more than 50 iButtons daily. Increasing the duration of the pulse also effectively reduces the number of iButtons that can be read in a short period of time because PulseStar cannot read an iButton while it is pulsing. PulseStar Communications software automatically sets it to 500 milliseconds (1/2 second) at its first communications. “Good read” pulse intensity – This setting increases or decreases the duty cycle of the motor. The factory setting of 5 represents a 50% duty cycle. Increasing the “Good read” pulse intensity to 10 (or 100% duty cycle) effectively doubles the current draw of the motor and could significantly reduce battery life. Delay before recording ID of same iButton – Since the PulseStar will read and record iButton ID’s very quickly, it is likely to read and record an iButton more than once when you only intended to record it once. This setting imposes a delay in 2 second increments that gives you some time to remove the reader from the iButton after the iButton ID is recorded in the PulseStar’s memory and the PulseStar emits its pulse. This delay is not imposed when you read iButtons with different IDs. Page 15

Page 19

PulseStar PC Software - Tab Windows Attempt to read data from iButtons – The PulseStar can read and record data from iButtons written in the Dallas default data structure. Since this function adds to the overall iButton reading time, it is turned off by default but may be enabled by toggling this control. Set As Default button – Takes the settings from the current window and stores them as the default. The following pop-up appears:

Figure 12 - Set As Default

Unless you choose otherwise, all PulseStars in the system will be updated to the new default settings when they are encountered. Restore Default button – Retrieves your stored defaults from memory and writes them to the fields in the window. Status button - displays the configuration settings read from the PulseStar during its most recent communications.

Figure 13 - PulseStar Status

Page 16

Page 20

PulseStar PC Software - Tab Windows

Status of communications with Blue Dot reader

Figure 14 - iButton Tab iButton Tab This tab displays a list of iButtons in your system. To assign a name or description to an iButton, simply type in a name. The Transfer grid will automatically update with the new name. iButtons not in the list will be automatically entered into the list during communications. If you wish to add iButtons from the Edit menu, choose “Manually Add iButton” to type into the entry form (Figure 15). Alternatively you can use the Blue Dot reader to manually add iButtons. The Blue Dot reader is an optional accessory. Before using the Blue Dot reader, make sure that the correct serial port has been selected for this device. (From the Settings menu, choose Communications, and then select an iButton reader serial port.) Tab headings: iButton ID iButton Name -

Unique factory ID User-defined name

Figure 15 - Manually Add iButton

Page 17

Page 21

PulseStar PC Software - Drop-Down Menus File Menu New - Create new data file Open - Open existing data file Save As - Save as Access database file (*.mdb) or as text file (*.txt) Print Setup - Standard print setup Print - Standard print options Exit - End program

Edit Menu Cut - Future use Copy - Future use Paste -Future use Remove Record(s) - Removes record(s) (Transfer and Configuration screens) Remove iButton - Removes iButton from iButton screen Manually Add iButton - Allows user to add iButtons manually

Settings Menu Communications Data Transfer Serial Port - Select the communication port to which the base station is physically attached. Blue Dot Reader Serial Port - Select the communication port to which the iButton Reader cable is physically attached. PulseStar Settings Clear PulseStar data after transfer (Default) Set PulseStar clock after transfer - Update each PulseStar after download is complete. (Default) Warn if battery voltage drops below threshold - Allows user to set low battery voltage threshold. (Default 2.51V)

Figure 16 Communications Options

Page 18

Page 22

PulseStar PC Software - Drop-Down Menus Raw Scan File Output to Videx raw data file in addition to writing to the database This option allows the software to create a Videx raw data file in addition to the database file (.mdb) that is created automatically. This option is provided to allow compatibility with previously existing applications. Contact Videx Customer Service for more information. Data File Name - Allows user to select location and name of data file. Replace iButton ID with iButton data when there is data read from the iButton - When this option is checked, the PulseStar will read the data that has been written to the iButton’s memory instead of the ID of the button, and write it to the raw scan file. Data Indentation - Select Spaces, Tab, or None - This option allows user to select what type of indentation will be used in the data file.

Figure 17 Raw Scan File Options

Look for PulseStar - When this menu option is checked, the software continually searches for the PulseStar for data transfer.

Page 19

Page 23

PulseStar PC Software - Drop-Down Menus Help Menu About - Version of PulseStar Software

Figure 18 - About PulseStar Communications

Page 20

Page 24

PulseStar Battery Replacement The PulseStar is shipped with a 3V lithium battery. The life of this battery in sleep (storage) mode is up to 1 year or up to 40,000 reads when using default settings. Exact battery life depends upon actual use. CAUTION: To help insure data integrity, download the PulseStar prior to changing the battery. The system is designed to avoid data loss, but observing this caution provides added protection. To replace the battery, remove the battery cap using the spanner wrench provided with the PulseStar (Figure 19).

Figure 19 - PulseStar Spanner Wrench

Unscrew the battery cap counterclockwise. Replace the old battery with a new one, replace the battery cap, and tighten until snug. The new battery should be installed with the positive terminal facing toward the PulseStar read head (Figure 20). Replacement batteries are available in most photography outlets.

Figure 20 - Battery Installation

Page 21