Page 9
Connecting the Base Station to a Computer The following steps describe how to connect a PulseStar Base Station to the computer’s serial port. You will need a computer, PulseStar Base Station, and a Videx serial port cable (TWC-001 (DB25) or TWC-008 (DB9)).
Figure 5 - PulseStar Base Station Connections
1.
Shut down the computer.
2.
Plug the Base Station’s power transformer (Output: 12 VDC 300 mA) into an electric outlet.
3.
Plug the other end of the transformer cable into the Power socket on the side of the Base Station. See Figure 4.
4.
Verify that the Power light on the Base Station is lit.
5.
Connect the serial port cable’s connector (9-pin or 25-pin) to your computer’s serial port. You can use com ports 1, 2, 3, or 4. (Note: The serial ports on a DOS/Windows computer are always a male connector. Pin-outs for the Videx serial port cables are provided on the software CD.)
6.
Connect the serial port cable’s RJ-11 plug to the Computer port of the Base Station.
7.
The Base Station must be placed at least three inches away from the computer and monitor to prevent the possibility of high levels of electromagnetic interference hindering communications.
Page 6
Page 10
Using Multiple PulseStar Base Stations
Figure 6 - Base Stations in Series
Up to 10 Videx Base Stations, holding 20 PulseStars, can be connected in series to a single serial port; this allows the user to transfer data from multiple data collectors in a single transfer process. You can transfer data from up to 20 units at a time. Note: The additional base stations are powered from the first one, so no additional power transformers are required in most cases.
Connecting the Base Stations To connect multiple Base Stations: 1) Connect the first Base Station to the computer’s serial port: a) Plug the Base Station’s transformer into an electric outlet and connect the other end into the Base Station’s Power connection. b) Use the serial port cable to connect the computer’s serial port to the Base Station’s Computer port. c) The Base Station should be placed at least three inches away from the computer and monitor. 2) To add additional Base Stations: a) Use an interconnect cable (TWC-006) to connect the Extension port of the first Base Station to the Computer port on the second Base Station. b) Continue the same pattern of connection for each additional unit.
Page 7
Page 11
Using Multiple PulseStar Base Stations To avoid problems when using multiple Base Stations, you need to be aware of the following caution: Caution: When transferring data from the PulseStars, do not interrupt the process by removing a PulseStar from its Base Station or aborting the program. The system is designed to avoid data loss, but observing this caution provides added protection.
If you should inadvertently remove a PulseStar while it is in the process of transferring data, the software displays a message that it was unable to communicate with the unit and then continues to try to transfer the data from all of the other PulseStars. The data in the interrupted unit will not clear and can be transferred after the others have completed their data transfer.
Page 8
Page 12
iButton An iButton (also known as an Touch Memory Button) is a memory chip housed in a stainless steel container. The stainless steel container protects the memory chip and also provides an electrical path for communication. The top of the button is connected to the enclosed memory chip circuit, and the bottom and sides of the button provide a signal ground. When a PulseStar touches an iButton, the top and the sides of the button are connected and an electrical path is established. Through this path, data is transferred at up to 16,000 bits per second. All iButtons contain a unique serial number (12 hexadecimal digits) that is programmed into the button at the factory. The serial number is unalterable and uniquely identifies each button. The PulseStar reads the ID number in all iButtons. Optionally you can configure the PulseStar to read data written to buttons in Dallas default data structure from the following iButtons: 1982, 1985, 1986, 1992, 1993, and 1994. In addition to the iButton ID number, the data stored in the iButton’s memory can be transferred from the iButton to the PulseStar. This option is OFF by default and must be enabled with PulseStar Communications software.
Page 9
Page 13
Software Installation If the PulseStar Autoplay window (Figure 7) appears when you insert the PulseStar CD into your CD drive, you can use it to install and explore the contents of the CD. If the default settings on your Windows system prevent the Autoplay window from appearing, you can simply follow the instructions in this document to install and explore the contents of this CD. To install PulseStar software, click the “Install PulseStar Software” button in the PulseStar Autoplay window. (Or, use Windows Explorer to locate and open the PulseStar CD and double click the “Setup.exe” file.) When the installer appears, follow the on-screen instructions.
Figure 7 - PusleStar Autoplay window
Page 10
Page 14
Getting Started Start PulseStar Communications by selecting Programs and then PulseStar Communications from the Windows Start menu. When PulseStar Communications first starts, it will attempt to use COM1 on your computer. If COM1 is not available, it will display the message “Unable to Open COM1” in the status bar at the bottom of the window. To use a different COM port, choose “Communications” (F2) from the “Settings” menu, and select one of the four available COM ports as your Data Transfer Serial Port. Then click OK. If “Looking for PulseStar on COMx” does not appear in the status bar, then from the “Settings” menu, choose “Look for PulseStar” to start the process. The Receive light on the PulseStar Base Station should now be lit. Now insert a PulseStar into the base station. PulseStar Communications will find it, configure it, and add it to the list of PulseStars in the Configuration tab. If there is any data it will transfer it, clear the data from the PulseStar, set the PulseStar’s clock, and display the data in the Transfer tab. It will also add any iButtons to the list in the iButtons tab that are not already there.
Page 11
Page 15
PulseStar PC Software - Tab Windows
Status of communications with PulseStar
Name and location of data file
Figure 8 - Transfer Tab
Transfer Tab This tab shows data transferred from the PulseStar. In this window you may sort or filter the data, then export or print it. Click on column headers to sort. (Note: Cannot sort on iButton data.) Data can be filtered by “Factory ID,” “Name or Serial Number,” or “iButton Name or ID.” To filter data, first highlight the field to be filtered by single clicking on it. Then if you double click on that cell, filtered data will appear in the Transfer window. To return the view to showing all data, double click on any of the column header fields. Tab headings: Factory ID Unique ID of PulseStar Name or Serial Number - User-defined serial number or name for PulseStar
Page 12
Page 16
PulseStar PC Software - Tab Windows Date and Time iButton Name or ID iButton Data -
Date and time of iButton read iButton ID read Data retrieved from iButton. To read this data, first highlight the iButton data field by single clicking on it. Then if you double click on that field, the iButton data will be displayed (Figure 9).
FacilityNameAcmeWarehouseFacilityOwnedByAcmeInc FacilityHasFourEntriesFacilityAddressOnePlazaPlace LaurenceHarborNewJerseyFacilityRestrictionsNoEmployee EntryAfterSevenPMFacilityEmergencyPrimaryContact JamesWhiteSecondaryContactMikeBrownFacilityLocatedIn DistrictFiveFacilityChemicalHazardCodeOneFacilityLockDown TwoCorporateManagersNeedToAuthorizeFacilityOpening AfterLockDown
Figure 9 - iButton Data
Page 13