Page 25

PulseStar Battery Information The following chart provides an estimate of the days of battery life for PulseStar; it assumes that the PulseStar will be used 9 hours in a day, then downloaded and put into sleep mode. The PulseStar pulse duration is set at 1000 milliseconds (1 second) when it is shipped from the factory. PulseStar Communications software automatically sets it to 500 milliseconds (1/2 second) at its first communications.

PulseStar Low Battery Level Warning Both the PulseStar reader and PulseStar Communications software provide a low battery warning. The warning is triggered when the measured battery voltage drops below a threshold. If it does, the PulseStar’s LED stops flashing and, if enabled, the PC will post a warning after completing communications with the PulseStar.

By default, the threshold voltage is 2.51, but it may be adjusted if desired. You may select from 2.19, 2.35, 2.51, 2.66, and 2.82 volts. The new threshold is programmed into each PulseStar at its next communication session.

Page 22

Page 26

PulseStar Flashing LED A light-emitting diode in the read head of the PulseStar is a status indicator. The following light patterns indicate the corresponding status: 1 flash every 2.3 seconds

PulseStar battery level is above the low threshold, and it is checking every flash for a communications signal from the PC.

Double flash every 4.6 seconds

PulseStar battery level is above the low threshold, but it is not checking for communications from the PC. This is the low power sleep mode set by the PC after data transfer.

Steady on

PulseStar infrared communications circuit is powered on and is ready to communicate with the PC. Typically this mode is invoked by the PC software, but it may also be invoked by reading the same iButton 10 times in a row. The next button touch turns off the IR circuit and the LED.

Off

PulseStar battery level is below the low threshold or PulseStar is nonfunctional.

Page 23

Page 27

Developers Please refer to the technical documents included on the PulseStar Communications CD.

PulseStar Error Codes and Descriptions Error Number

Error Text

1000

"No error has occurred."

1001

"An attempt to allocate or reallocate memory failed."

1002

"An attempt to access a file failed."

1003

"An attempt to manipulate a comm port failed."

1004

"A synchronization error occurred while attempting to communicate with a button reader."

1005

"The function was interrupted by user input."

1006

"An invalid PulseStar ID was detected."

1007

"An invalid command was sent to the PulseStar."

1008

"No data is available."

1009

"A time-out occurred."

1010

"A bad bit value was specified for the PulseStar configuration bit variable."

1011

"No data is available."

1012

"Attempt to synchronize with the PulseStar failed."

1013

"One or more parameters contained an illegal value."

1014

"An error of unknown type occurred."

Page 24

Page 28

PulseStar Troubleshooting If you have problems with your PulseStar system, try the following troubleshooting tips. If you continue to have problems, contact Videx Customer Service by phone at (541)758-0521, by fax at (541)752-5285, or by e-mail at support@videx.com. My computer will not download data from the PulseStar. 1.)

If the status bar at the bottom of the PulseStar window displays “Unable to Open Comx,” then the serial port may be in use by another program or device. To free up the serial port for use by the PulseStar, disable that program or device.

2.)

If the status bar displays “PulseStar Communications are idle,” from the “Settings” drop-down menu, be sure that “Look for PulseStar” is checked.

3.)

If the status bar displays “Looking for PulseStar on Comx” or “Unable to Open Comx,” make sure that the correct serial port has been selected. You can change the serial port by clicking on “Settings” and then selecting “Communications.”

4.)

If the status bar displays “Looking for PulseStar on Comx,” try cleaning the outside surface of the PulseStar’s IR link (the recessed circular area in the read head). If dust or debris accumulates here, it can interfere with the PulseStar’s ability to communicate. A Q-tip or similar item can be used to clean this area.

5.)

If the status bar displays “Looking for PulseStar on Comx,” be sure that the PulseStar is firmly seated in the downloader.

6.)

If the PulseStar LED is not flashing, replace the battery.

Page 25

Page 29

PulseStar Specifications Physical: Sealed plated aluminum case that resists scratches, drops, and water Weight: 3.7 oz (105 g ) Dimensions: Length 5 1/8”; diameter 15/16” (130.2 x 23.8 mm) Memory: 48K byte chip Storage Capacity: Up to 5400 iButton ID reads Battery: 3V lithium, 2/3 “A” size (Eveready Energizer EL123AP or equivalent) Battery Life: Up to 1 year or up to 40,000 continuous reads (default settings) Clock: Real-time clock with capacity to operate up to 1 minute after battery disconnected Communications: IrDA Layer 1 (HP/SIR) Transfer Rate: Full memory will transfer in approximately 26 seconds (57,000 bps) Data Output: Access database and/or ASCII text file iButton: Reads ID in all iButtons. Optionally reads data written to buttons in Dallas default data structure (not TMEX) from these iButtons: 1982, 1985, 1986, 1992, 1993, and 1994. Data is stored in memory with button ID. This option is OFF by default and must be enabled with software. Storage Temperature: -40° to 149°F (-40° to 60°C) Operating Temperature: 32° to 122°F (0° to 50°C) Humidity: 5% to 95% noncondensing

PulseStar Downloader Specifications Dimensions: 4.0” x 4.1” x 1.8” (102 x 105 x 46 mm) Weight: 8.2 ounces (232.5 g) Number of Readers: 2 Power Supply Adaptors: 120 volt, 60 Hz; 220 volt, 50 Hz Indicator Lights: Transmit, Receive, Power Connection Ports: Computer, Extension, Power Serial Communications: Standard RS-232 Page 26

Page 30

PulseStar Configuration Options Motor duty cycle (Read/Write):

Read RAM in iButton:

1 - 10 (default 5 which is 50%) PC software presents this as “Good read” pulse intensity. On -Off (default Off) This option increases read time on all buttons if enabled.

DLL Settings Motor running time (Read/Write):

0 - 12 seconds (default 1000 milliseconds) PC software calls this Duration of “good read” pulse. Allows range of 100 1000 ms. NOTE: 0 - 1 second adjustable through PulseStar Communications Software.

Time between automatic IrDA sync retries:

0 to 586 seconds (default 2.3 seconds)

Time attempting to sync:

Turn off ability to wake up by shorting contact:

1 - 255 ms (default 10 ms)

On - Off (default On)

Refer to “Data Communications DLL Specification for PulseStar” document for information regarding additional settings. Technical documents can be located on the PulseStar Communications CD.

Page 27

Page 31