Manual · Vicon
V1400X-IDL Intelligent Distribution Line Control
Manual25 pagesPDF 369 KB
Installation and operation manual for the Vicon V1400X-IDL Intelligent Distribution Line Control for RS-422 video control systems.
Covers · 1 model
The models it covers
Summary
What is in it
The installation and operation manual for the Vicon V1400X-IDL Intelligent Distribution Line Control, which connects a Vicon control and matrix system (CPU) to up to 10 Vicon RS-422 input or output devices and isolates faulty stations. It covers quick installation, unpacking, desk and rack mounting, cabling to the CPU, keypads, consoles, receivers and domes, addressing and operation verification, fuse replacement, shipping, cable recommendations and technical information.
Its parts
- Quick Installation
- Introduction
- Installation
- Operation
- Maintenance
- Shipping Instructions
- Reference
- Technical Information
From the manual · read page by page
Key facts from this manual
Each line names its page in the PDF.
A 2002 Vicon installation and operation manual for the V1400X-IDL Intelligent Distribution Line Control and its 230 VAC version, the V1400X-IDL-230, which links a Vicon control and matrix system to up to 10 RS-422 keypads, consoles, receivers or domes. It walks through mounting, wiring each station port, checking operation and replacing the fuse, and ends with the technical specifications.
- Device
- Distribution line control linking a Vicon control and matrix system (CPU) to up to 10 RS-422 input or output devices, isolating faulty stations p. 8
- Connectors
- CPU on J11 and stations STAT J1 to J10, each a 6-pin removable screw terminal block p. 23
- Control format
- RS-422, full duplex, 4800, 9600 or 19200 baud p. 24
- Power
- V1400X-IDL: 120 V, 60 Hz; V1400X-IDL-230: 230 V, 50 Hz; 9 watts p. 8, 23
- Input and output devices
- Inputs: V1300X-DVC/RVC, V1400X-DVC; outputs: V1200R-LM, V1301R, V1311RB, V1319R, V15UVS, V7UVS, V5UVS, SUR2000 p. 22
- Compatible CPUs
- V1200X, V1300X, VPS328/V1422 p. 22
- Size and weight
- 1.7 in. (43 mm) high, 19.0 in. (483 mm) wide, 7.5 in. (191 mm) deep; 6.5 lb (2.9 kg) p. 24
- Operating environment
- 32 to 122°F (0 to 50°C); up to 90% relative humidity, noncondensing p. 24
- Fuse
- 120 VAC: 5mm x 20mm, 0.25 A, slo-blo; 230 VAC: 5mm x 20mm, 0.125 A, slo-blo p. 23
- Mounting
- Desktop on rubber bumpers or an EIA 19-inch rack, with about 1.75 inch (45 mm) between rack units p. 10
- Indicators
- Red power LED, yellow CPU LED (intelligent mode only), green station LEDs p. 23
- DL/IDL switch
- Rear slide switch: IDL is intelligent mode, DL simply passes commands p. 8, 23
- Accessory kit
- 4 rubber bumpers, a spare fuse, a power cord and 11 pre-terminated 6-position terminal block plug-in modules p. 10
- Recommended cable
- Shielded twisted pair: Belden 9406, 9402, 8723, 8162, 9729 or 9182 p. 22
What this manual walks you through
- Mounting the unit on a desk or in a 19-inch rack p. 10
- Wiring the CPU cable to the J11 terminal block p. 11
- Connecting V1300X-DVC/RVC keypads to the station ports p. 11, 12
- Connecting a V1400X-DVC System Console through an RJ-45 termination box p. 13
- Wiring receivers and domes, including the Surveyor2000 by RJ-45 p. 14, 15, 16
- Daisy-chaining several IDL units to one CPU p. 18
- Checking operation after power-on with input or output devices p. 19
- Replacing the fuse in the rear power block p. 20
- Packing and returning a unit for repair p. 21
Good to know
- Input devices (keypads, consoles) and output devices (receivers, domes) must not share one IDL unit. p. 17
- Every device on one IDL needs its own address; stations sharing an address are switched on and off intermittently. p. 17
- The IDL has no failsafe: if the first unit in a daisy chain fails or is off, the units after it lose the CPU. p. 18
- Unused station terminal blocks carry an end-of-line jumper between pin 5 and pin 4, which must be removed when the port is used. p. 12
- Set the DL/IDL switch before power-on; a change made with power applied needs the unit unplugged to take effect. p. 17
Questions this manual answers
How many devices can connect to a Vicon V1400X-IDL?
Up to 10 input or output devices; when IDLs are daisy chained, each unit but the last has 9 station ports left. p. 17, 18
What do the CPU LED blinks mean on the V1400X-IDL?
After it detects the baud rate (about 45 seconds), one blink means 4800 baud, two mean 9600 and three mean 19200. p. 19
Why is a station LED off on the V1400X-IDL?
The IDL found that line corrupt and shut the station down; it lights the LED again when the line becomes valid. p. 19
What fuse does the V1400X-IDL take?
A 5mm x 20mm slo-blo fuse: 0.25 A on 120 VAC units, 0.125 A on 230 VAC units. p. 23
What does DL mode do on the V1400X-IDL?
It passes commands only, without detecting station status or locking onto the baud rate. p. 8
Contents
Chapters and sections
Each line opens the PDF at its page.
The whole text · 3 parts
Read the manual here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.