Page 10

Installation Unpacking and Inspection All Vicon equipment is tested and inspected before leaving the factory. It is the carrier’s responsibility to provide suitable delivery. Inspect the cartons upon delivery and, if damage is present, make detailed notes on the carrier’s bill. Then, obtain the carrier agent’s signature and file a damage claim as soon as possible. Open the cartons and inspect the equipment for damage. Save the cartons and packing material. If damage is present, contact the carrier and file a damage claim immediately. If the equipment must be returned to Vicon for repair, follow the instructions in the Shipping Information Section of this manual.

Physical Installation The IDL is designed for desktop use or for installation in an EIA standard 19-inch (483 mm) instrument rack. During rack installation, it is important that approximately 1.75 inch (45 mm) of space is left between each rack mount unit for ventilation. This spacing also provides easier access to equipment back panels.

Accessory Kit An Accessory Kit is provided which includes 4 rubber bumpers, a replacement Fuse, a power cord with the correct molded plug and 11 pre-terminated, 6 position Terminal Block plug-in Modules.

Desk Mount The IDL can be used on a solid desk surface. Use the 4 rubber bumpers provided to make a stable base. Attach an adhesive-backed bumper to each corner of the bottom surface and press firmly.

Rack Mount The IDL can be rack mounted using hardware supplied with the Rack. Simply place the IDL at the desired position and attach it using 4 screws. No additional support is required.

Cabling The IDL must be connected to power, CPU and I/O Device controls. This sub-section will detail complete cabling, which is comprised of Power, CPU and I/O Device Connection sub-sections.

Power Connection The IDL is factory set for its operating voltage and requires only proper use of the provided line cord. NOTE: Do not apply power to the IDL until all cabling with the CPU and I/O devices has been completed. Verify that the correct fuse is installed in the Active Fuse Holder as shown in Figures 1 and 2. Attach the provided Power Cord to the Rear Panel Power Block. NOTE: Vicon strongly recommends the use of line conditioners, voltage regulators and uninterruptible power supply systems (UPS) to prevent voltage fluctuations that can affect operation and cause damage to the equipment. Figure 2 Rear Panel Power Block

6 • Installation

XX017-01-00 Rev 702 V1400X-IDL Intelligent Distribution Line Control

Page 11

CPU Connection The IDL uses standard RS-422 protocol on connector J11 (6-pin Terminal Block connector). Prepare a length of Shielded, Dual Twisted-Pair Cable to have 6 dressed wires. Use the pin designations in Figure 3 for J11. See the Reference Section of this manual for applicable CPU Control System manuals denoting Keypad pin designations. Refer to the Reference Section of this manual for Table 1, Shielded, Dual Twisted-Pair Cable Maximum Operating Distances. 1. Fabricate the cable as described above. It is recommended to label both cable ends. 2. Connect the CPU end of the cable to the Keypads connector on the CPU. 3. Terminate the IDL wire ends of the cable into the CPU (J11) Terminal Block and press it into the Panel Connector. Figure 3 J11 Pin Definition for CPU Cable

The IDL uses standard RS-422 protocol on connectors J1-J10 (6-pin Terminal Block connectors). Prepare a length of Shielded, Dual Twisted-Pair Cable to have 6 dressed wires. Use the pin designations in Figure 4 for J1-J10. Refer to the applicable I/O Device manual for pin designations. Refer to the Reference Section of this manual for Table 1, Shielded, Dual Twisted-Pair Cable Maximum Operating Distances.

V1300X-DVC/V1300X-RVC Keypads Connect the 6 dressed wires from the other end of the Station 1 (J1) cable to the Terminal Block (J1) on the Keypad. Use the pin designations in Figure 5 for connection. NOTE: STAT 1/J1 is used to represent any of the 6- position Panel Connectors.

Figure 4 J1-J10 Pin Definition for I/O Device Cable

XX017-01-00 Rev 702 V1400X-IDL Intelligent Distribution Line Control

Installation • 7

Page 12

1. Fabricate the RS-422 protocol cable as described above. It is recommended to label both cable ends. 2. Connect the Master Keypad end (open wires) of the cable to the Screw Terminal Block (J1) on the Keypad, as shown in Figure 5. 3. Press the 6-position Terminal Block end of the cable into the STAT 1/J1 connector. 4. (Optional) Connect Slave Keypads as described in Vicon Installation and Operation Manual X777. 5. Connect additional cables to consecutive Station connectors (2, 3, 4, etc.). NOTE: All unused station (STAT) port Terminal Blocks are terminated with an end-of-line jumper. Remove this small wire between the Response In - signal (Pin 5) and Ground (Pin 4) when using the port.

Figure 5 STAT 1 (J1) - STAT 10 (J10) Pin Definition for V1300X-DVC/RVC Cable

8 • Installation

XX017-01-00 Rev 702 V1400X-IDL Intelligent Distribution Line Control

Page 13

V1400X-DVC System Console Connect the 6 dressed wires from the other end of the Station 1 (J1) cable to the RJ-45 Termination Box screw terminals. From here, use the RJ-45 to RJ-45 6foot cable, provided with the System Console, to connect between the Termination Box and the System Console. 1. Fabricate the cable as described above. Connect the 6 dressed wires to the RJ-45 Termination Box as shown in Figure 6. 2. Connect the System Console (RJ-45 connector) end of the 6-foot cable to the RJ-45 connector on the System Console, as shown in Figure 6. 3. Connect the other end of the 6-foot cable (RJ-45 connector) to the Termination Box. 4. Connect additional cables to consecutive Station connectors (2, 3, 4, etc.). NOTE: All unused station (STAT) port Terminal Blocks are terminated with an end-of-line jumper. Remove this small wire between the Response In - signal (Pin 5) and Ground (Pin 4) when using the port. NOTE: Refer to Vicon Instruction Manual XX090 for information on daisy chaining additional System Console units to the V1400X-DVC Master System Console.

Figure 6 STAT 1 (J1) - STAT 10 (J10) Pin Definition for V1400X-DVC Cable

XX017-01-00 Rev 702 V1400X-IDL Intelligent Distribution Line Control

Installation • 9

Page 14

Receivers and Domes For Terminal Block applications, connect the 6 dressed wires from the other end of the Station 1 (J1) cable to the Terminal Block on the appropriate device. Use the pin designations in Figures 7-13 for connection.

Terminal Block Applications 1. Fabricate the RS-422 protocol cable as described above. It is recommended to label both cable ends. 2. Connect the end (open wires) of the cable to the appropriate Screw Terminal Block on the Receiver, as shown in Figures 7-13. 3. Press the 6-position Terminal Block end of the cable into the STAT 1/J1 connector. 4. (Optional) Connect a daisy-chained Receiver as described in the corresponding Vicon Receiver Installation and Operation Manual. Figure 7 STAT 1 (J1) - STAT 10 (J10) Pin Definition for V1200RLM-1 Cable

5. Connect additional cables to consecutive Station connectors (2, 3, 4, etc.).

NOTE: All unused station (STAT) port Terminal Blocks are terminated with an end-of-line jumper. Remove this small wire between the Response In - signal (Pin 5) and Ground (Pin 4) when using the port.

Figure 8 STAT 1 (J1) - STAT 10 (J10) Pin Definition for V1319R Cable

10 • Installation

XX017-01-00 Rev 702 V1400X-IDL Intelligent Distribution Line Control

Page 15

RJ-45 Connector Applications (Surveyor2000) For RJ-45 connector applications, connect the 6 dressed wires from the other end of the Station 1 (J1) cable to the RJ-45 Termination Box screw terminals. From here, use the provided RJ-45-to-RJ-45 6-foot cable to connect between the Termination Box and the RJ-45 connector on the appropriate device. 1. Fabricate the cable as described above. Connect the 6 dressed wires to the RJ-45 Termination Box. 2. Connect the Receiver (RJ-45 connector) end of the 6-foot cable to the appropriate connector as shown in Figure 13. 3. Connect the other end of the 6-foot cable (RJ-45 connector) to the Termination Box. 4. (Optional) Connect a daisy-chained Receiver as described in the corresponding Vicon Receiver Installation and Operation Manual. 5. Connect additional cables to consecutive Station connectors (2, 3, 4, etc.). Figure 9 STAT 1 (J1) - STAT 10 (J10) Pin Definition for V1301R Cable

Figure 10 STAT 1 (J1) - STAT 10 (J10) Pin Definition for V1311RB Cable

Figure 11 STAT 1 (J1) - STAT 10 (J10) Pin Definition for V7UVS Cable

XX017-01-00 Rev 702 V1400X-IDL Intelligent Distribution Line Control

Installation • 11

Page 16

Figure 12 STAT 1 (J1) - STAT 10 (J10) Pin Definition for V15UVS Cable Figure 13 STAT 1 (J1) - STAT 10 (J10) Pin Definition for Surveyor2000 Cable

NOTE: The RJ-45 connector can be used instead of the Terminal Block on the Surveyor2000.

12 • Installation

XX017-01-00 Rev 702 V1400X-IDL Intelligent Distribution Line Control

Page 17

Operation The V1400X-IDL allows up to 10 I/O Devices to be connected to CPU-based Matrix systems. Since the V1400X-IDL has panel indicators and no controls, individual I/O Devices are used for operation. Refer to the Reference Section of this manual for I/O Device and CPU Instruction Manual numbers.

Requirements and Characteristics Addressing All I/O Devices’ addresses must be unique within an IDL unit (no two I/O Devices can be addressed 1, for example). In the event that two or more Stations share the same address, the IDL will intermittently enable and disable those individual Stations.

Basics When Input Devices are connected, all can operate the CPU simultaneously. Any combination of Keypads or System Consoles can be used with an IDL unit. When Output Devices are connected, all devices can be operated by the CPU simultaneously. Any combination of different Receiver types can be used with an IDL unit. Operation of the IDL is transparent to the user when proper monitor partitioning and camera seize control is established on the CPU. The DL/IDL switch must be selected for intelligent mode prior to powering on the unit. If the switch is toggled with power applied, the unit must be reset (temporarily unplug unit) for the mode to be toggled. Refer to the Instruction Manual for the particular CPU control system for information on establishing monitor partitioning and camera seize control. Figure 14 shows the IDL with individual Station ports setup in 2 typical configurations using V1300XDVC/RVC Keypads and V1400X-DVC System Consoles as Input Devices. The CPU can be controlled from all Input Devices. However, Keypad 2 can only control the CPU when Keypad 1 (Master Keypad) is powered on. All four Input Devices must have unique addresses or operation conflicts will occur. Up to 10 Input Devices can be connected to the IDL.

Figure 14 Typical System Setup With Input Devices

NOTE: Do not connect Input Devices (Keypads/System Consoles) and Output Devices (Receivers/Domes) to the same IDL unit, as they will not operate correctly.

XX017-01-00 Rev 702 V1400X-IDL Intelligent Distribution Line Control

Operation • 13

Page 18

Figure 15 shows the IDL with individual Station ports setup in a typical configuration using Receivers and Domes as Output Devices. The CPU can control all Output Devices. Dome 1 can be operated even when the V1311RB Receiver is malfunctioning or not powered on because this Receiver has a built-in failsafe device. However, Receivers that do not have built-in failsafe circuitry must be powered on and operative for successive daisy-chained devices to operate. All Output Devices must have unique addresses or operation conflicts will occur. Up to 10 Output Devices can be connected to the IDL.

Figure 15 Typical System Setup With Output Devices Figure 16 shows 3 IDLs daisy chained to a CPU. IDLs have 9 remaining STAT ports for I/O Devices, except for the last unit which has 10 STAT ports available. IDL 1 communicates directly with the CPU, passing information from and to its connected I/O devices. IDL 2 communicates with the CPU through IDL 1, which passes information from and to its connected I/O devices. However, if IDL 1 is malfunctioning or is not powered on, IDL 2 and IDL 3 will lose communication with the CPU, because there is no failsafe circuitry provided in the IDL. IDL 3 communicates as IDL 2 does, through IDL 1. NOTE: Do not connect Input Devices (Keypads/System Consoles) and Output Devices (Receivers/Domes) to the same IDL unit, as they will not operate correctly.

Figure 16 Typical System Setup With Daisy-Chained IDLs

14 • Operation

XX017-01-00 Rev 702 V1400X-IDL Intelligent Distribution Line Control