Vicon's two-page product specification (2000) for the V1400X-IDL and V1400X-IDL-230 Intelligent Distribution Line Control, which connects a Vicon control and matrix system to up to 10 RS-422/485 input or output stations. It gives a contractors' specification and the electrical, environmental, connector, operating and mechanical data.

Device
Intelligent distribution line control linking a Vicon control and matrix system to up to 10 RS-422/485 input or output stations p. 1
Connectors
6-pin removable screw terminal blocks: CPU (J11) and one per station (STAT J1-J10); rear grounded female power connector p. 2
Control format
RS-422/485, simplex or half duplex, at 4800, 9600 or 19,200 baud p. 2
Input voltage
V1400X-IDL: 120 V, 60 Hz. V1400X-IDL-230V: 230 V, 50 Hz; 9 Watts p. 2
Fault isolation
Detects corrupt stations (device locking, incorrect wiring, excessive noise) and isolates them from the others p. 2
Indicators
Red power LED, green CPU LED, green station LEDs on the front panel p. 2
Mounting
Desk (bumpers provided) or standard 19 inch (48 cm) rack p. 1, 2
Size and weight
1.7 in. high, 19.0 in. wide, 7.5 in. deep (4.3 x 48.3 x 19.1 cm); 6.5 lb (2.9 kg); shipping weight 8.2 lb (3.7 kg) p. 2
Fuse
120 VAC: 3AG, 0.25 A, slo-blo; 230 VAC: 3AG, 0.125 A, slo-blo p. 2
Operating temperature
32 to 122° F (0 to 50° C), up to 90% relative humidity, noncondensing; storage -40 to 150° F (-40 to 65° C) p. 2
Line cord
Standard 3-conductor SV No. 18 AWG cable with grounding plug p. 2
Construction
Steel chassis and cover, black baked enamel finish; indoor unit p. 1, 2
Product code
V1400X-IDL: product code 6825 p. 1

Good to know

  • The contractors' specification calls for an indoor unit only. p. 1
  • The 230 VAC model is the CE compliant one. p. 1
  • The heat figure assumes all electrical energy becomes heat; real heat output is lower. p. 2

Questions this sheet answers

How many stations can the Vicon V1400X-IDL connect?

Up to 10 Vicon RS-422/485 input or output devices, plus one CPU line. p. 1, 2

What baud rates does the V1400X-IDL support?

4800, 9600 or 19,200 baud, simplex or half duplex RS-422/485. p. 2

Is there a 230 V version of the Vicon V1400X?

Yes. The V1400X-IDL-230 runs on 230 V, 50 Hz; the V1400X-IDL runs on 120 V, 60 Hz. p. 1, 2

What happens if one station on the V1400X-IDL is miswired?

The unit detects the corrupt station, shows its status on the front panel LEDs and isolates it from the normal stations. p. 1, 2

The file

Size and text

Pages2
PDF476 KB
TextText from the PDF itself.

Every page · 2

Read it here

Each page as it is printed, and its words beside it, so a phone can search and copy them.

Page 1 of Vicon V1400X Spec Sheet

The text of page 1, from the PDF itself

Product Specification

The V1400X-IDL Intelligent Distribution Line Control Unit (IDL) is designed to provide convenient connection of a Viconbased Control and Matrix System to 10 Vicon RS-422/485 Input or Output Devices (Stations) using 6-position, removable Terminal Block connectors. This IDL provides “intelligent control” via microprocessor controlled circuitry which can individually detect the status of each Station and CPU line, display it via front panel LEDs, and shut down those corrupt Stations. Thus, the IDL can prevent Stations that are locked, incorrectly wired or that have high noise levels from interfering with the other stations. The IDL can be mounted on a desk or in a standard 19 inch (48 cm) rack and is available in a 120 VAC or 230 VAC model. The 230 VAC model is CE compliant.

V1400X-IDL and V1400X-IDL-230 Intelligent Distribution Line Control

  • Rack or desk mounting
  • Convenient removable terminal blocks
  • Standard RS-422/485 communucation
  • Provides “pass-through” control for up to 10 I/O devices

Contractors’ Specification INTELLIGENT DISTRIBUTION LINE CONTROL The Intelligent Distribution Line Control shall provide convenient connection of a Vicon-based CPU Control System to a maximum of 10 Vicon Input or Output Devices using RS-422/485 protocol on 6-position, removable Terminal Block connectors. The IDL shall have intelligence by employing a microprocessor to monitor the system status. It shall have the capability of detecting corrupt Station and CPU line communication and displaying their status using front panel LEDs. It shall have the ability to shutdown any,

Vicon Product Facts Vicon part number 8009-7017-00-00

or all, Station lines that it cannot communicate with. The IDL shall be mounted on a desk or in a standard 19 inch (48 cm) rack and shall be available in a 120 VAC or 230 VAC model. The IDL shall be strictly an indoor unit constructed of sheet steel with a black enamel finish. Height, width and depth shall not exceed 4.0 in. (10.2 cm), 20.0 in. (50.8 cm) and 12.0 in. (30.5 cm), respectively. Weight shall not exceed 6.5 lb (2.9 kg). The Distribution Line Control shall be Vicon’s base Model V1400X-IDL.

Model No: V1400X-IDL\ Product Code: 6825/ SEC: 11 SPEC: V017 REV: 300 V1400X-IDL-230 6825-01 Product specifications subject to change without notice.

Page 2 of Vicon V1400X Spec Sheet

The text of page 2, from the PDF itself

Technical Information ELECTRICAL

ENVIRONMENTAL

Input Voltage: V1400X-IDL: 120 V, 60 Hz. V1400X-IDL-230V: 230 V, 50 Hz. Power Consumption: 9 Watts. Heat Equivalent: 0.5 btu/min (0.13 cal/min). Note: These figures represent the conversion of 100% of the electrical energy to heat. Actual percentage of the heat generated will be less and will vary from product to product. These figures are provided as an aid in determining the extent of cooling required for an installation. Line Cord: Standard 3-conductor SV No. 18 AWG cable with grounding plug. Fuse: 120 VAC: 3AG, 0.25 A, slo-blo 230 VAC: 3AG, 0.125 A, slo-blo. Radio Frequency Emission Rating: FCC Class A. European Community (CE) Standards: EN 50081-1 generic emissions. EN-50082-1 generic immunity.

Operating Temperature Range: 32 to 122° F (0 to 50° C). Operating Humidity Range: Up to 90% relative, noncondensing. Storage Temperature Range: -40 to 150° F (-40 to 65° C). Storage Humidity Range: Up to 90% relative, noncondensing.

WD V1400X-IDL1234STATION5678910CPU POWERVICONH

CONTROLS & CONNECTORS Power (LED): Red front panel LED indicates power condition. Power (connector): Rear panel 120 or 230 VAC grounded female connector. CPU (LED): Green front panel LED indicates CPU condition. STATION (LEDs): Green front panel LEDs indicate Station conditions. CPU (J11): 6-pin removable Screw Terminal Block connector. Station (STAT J1-J10): 6-pin removable Screw Terminal Block for each connector. OPERATIONAL General: Unit is operated using external devices (1 CPU and up to 10 I/O Devices). If one or more Stations become corrupt (device locking, incorrect wiring or excessive noise), the unit will isolate these stations from the remaining normal ones. Control Format: RS-422/485 protocol data, simplex or half duplex operation at 4800, 9600 or 19,200 baud. MECHANICAL Mounting: Desk mount (bumpers provided) or Rack mount. Dimensions: Height: 1.7 in. (4.3 cm). Width: 19.0 in. (48.3 cm). Depth: 7.5 in. (19.1 cm). Shipping Dimensions: Height: 4.0 in. (10.2 cm). Width: 20.0 in. (50.8 cm). Depth: 12.0 in. (30.5 cm). Shipping Weight: 8.2 lb (3.7 kg) Weight: 6.5 lb (2.9 kg). Construction: Steel chassis and cover. Finish: Black baked enamel chassis and cover. 89 Arkay Drive Hauppauge, NY 11788 www.vicon-cctv.com

2 Copyright © 2000 Vicon Industries Inc. All rights reserved.

TEL: 631-952-2288 FAX: 631-951-2288 TOLL FREE: 800-645-9116

Vicon and its logo are registered trademarks of Vicon Industries, Inc.

More documents · 1

For the same models