The text of a manual · part 2 of 7
PT-805 User's Manual, pages 11 to 20
Pages 11 to 20 of 70
The original document is the PDF (2.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the Unitech PT815
Page 11
2.2 Battery Installations
NOTE Although a Lithium battery is installed it is electrically disconnected during shipment from the manufacturer. Prior to using the PT-805 for the first time, please set the Lithium battery backup switch to ON. ( see installation procedure below )
NOTE The PT-805 NiCd battery pack has been fully discharged before shipment. Prior to using the PT-805 for the first time, charge the NiCd batteries overnight or approximately 14 to 16 hours.
Procedure:
1. Remove the hand strap retainer at one end to provide access to the battery cover. 2. Remove the battery cover on the underside of the PT-805.
4. Set the Lithium battery backup switch to ON.
< - / a vA “ c ON OF
Page 12
5.
6.
Insert the main batteries:
@ NiCd battery: First, plug the charge connector of the NiCd battery pack t to the PT- 805, (See figure below). Then place back the whole pack inside the compartment. (reversing step 3).
V7,
A
@ Alkaline batteries: Orient them as shown by the polarity symbols in the battery compartment. Make sure that the battery poles are correctly oriented. Skip step 6, when using Alkaline batteries.
Replace the battery cover and replace the hand strap retainer. (reversing step 2 and 1).
If you are using NiCd pack, charge the NiCd batteries for 14 to 16 hours.
sv DC ar
ADAPTER WALL OUTLET
\
Page 13
2.3. Type of Batteries
Rechargeable NiCd Battery Pack One of the power source options for the PT-805 is the rechargeable NiCd battery pack, which consists of four AA-size NiCd batteries. The pack supplies 4.8V DC power with a capacity of 700 mAH (mA Hour) after being fully charged.
Alkaline Batteries
Alternately, PT-805 can use 4 AA-size Alkaline batteries. Use Alkaline batteries with a capacity of 700 mAH or more (normally with a capacity of 1000 mAH) are recommended.
Page 14
2.4 Backup Battery
The PT-805 uses an internal 3-Volt CR2032 Lithium battery for backup to the RAM memory and system real time clock when the main battery power is not available, such as being taken out or discharged. Under normal conditions, it takes years of inactivity or storage for the terminal to lose its backup power.
2.5 Low Battery Indication
Main Battery
A low main battery condition is indicated by a flashing LCD display when the PT-805 is in use. When a main battery low condition occurs, the main battery can continue to supply power for about two hours under normal use. The PT-805 will still work normally, with a flashing LCD indicating a main battery low condition. However it may reach the system power cutoff point and automatically turn off the PT-805.
The period of time the PT-805 may be used before reaching the cutoff point varies due to the power consumption of different scanners. Though it should not cause any data loss, a system cutoff may leave an incomplete transaction in the data collection operation. In this condition the unit continues to backup data and application programs in RAM memory, but it will not function until the batteries have been recharged or replaced.
Lithium Backup Battery When you turn on a PT-805 which has had its Lithium battery discharged or physically disconnected by having the on/off switch set to OFF, a backup battery low warning will be shown on the PT-805 LCD, as follows:
REPLACE LITHIUM BATTERY !
In this situation you should check the Lithium battery enable-switch and set the switch to ON if it is in OFF position. Upload your data from the PT-805 to the PC and have the Lithium battery replaced when the above message is shown with the switch set to ON. Contact your local sales or service representative for replacement of the Lithium battery.
-10-
Page 15
NOTE Data may not be backed up and data loss may occur if both the main battery and the Lithium battery are discharged. Refer to Section 2.1 Installation for proper management of the power source used in the PT-805.
Battery Service Time
Information below is provided as a reference. The actual service time may vary due to different application, type of battery, and operating environment. The user should understand the battery power system of PT-805 described in this chapter for maximum performance.
Continuous Operation: | When data is continuously entered by keypad or
WAND scanner. 1500 mAH Alkaline batteries: 12-14 hours 700 mAH NiCd battery pack (fully charged): 8-10 hours Data Backup: When the PT-805 is powered off. By main battery: 1500 mAH Alkaline batteries: 1.5 years
700 mAH NiCd battery pack (fully charged): 12 months
By Lithium battery: 8 months (in a situation where the main battery is unavailable)
2.6 Battery Replacement
The main batteries can use NiCd pack or Alkaline Batteries which are the same physical size, and installed in the same battery compartment of the PT- 805 (see Figure 2-1). Please refer to installation procedures in Section 2.1 Battery Considerations for replacement of the main battery. Contact your local sales or service representative for replacement of the backup battery.
Figure 2-1 Battery Compartment
-11-
Page 16
2.7 Recharging the NiCd Battery Pack
When the PT-805 gives a low battery indication (flashing LCD), the NiCd batteries need to be recharged. Plug a power adapter into the PT-805 and into a wall outlet. The installed NiCd battery pack will be fully recharged at the normal rate of 14 to 16 hours (see Figure 2-2).
9V DC JACK DC ADAPTER > <= WALL OUTLET
Figure 2-2 PT-805 with Power Supply
NOTE The AC-DC power adapter is only for NiCd battery pack recharging. It will not recharge Alkaline batteries.
Charging Consideration It is important to consider the surrounding temperature whenever you are charging NiCd batteries. The process is most efficient at normal room temperature or slightly cooler. It is essential that you charge batteries within the stated range of 32°F to 113°F (0°C to 45°C).
CAUTION Charging batteries outside of the specified range could damage the batteries and shorten their life cycle.
Effects of Overcharging Batteries Overcharging occurs when a battery is left in a charging device after it has been fully charged. NiCd batteries are capable of withstanding a reasonable amount of overcharging at the charging rate provided by a PT-805 portable terminal and charging modules without any damage being caused. However, if the NiCd batteries are charged for too long, they can sustain a temporary reduction of capacity. A battery left to charge for several weeks may appear to have minimal capacity. This type of failure is remedied by temporarily ' depleting the battery of its power and recharging it in the charging module to -12-
Page 17
rejuvenate it. This condition can be prevented by avoiding overcharging for long periods of time. The recommended charge time for NiCd batteries (charged with a portable terminal) is 14 to 16 hours.
2.8 Storage and Safety Precautions
NiCd batteries should be stored in an open circuit condition and placed where there is no risk of accidental shorting or other damage. Although charged NiCd batteries may not be used for several months, the capacity may be reduced due to backup support and internal resistance. They will then require recharging prior to use. NiCd batteries may be stored at temperatures between -4°F and 158°F (-20°C to 70°C ), however they may be depleted more rapidly at the high end of this range.
-13-
Page 18
Chapter3 Input Method
A Look at the PT-805
CHO GHD CA) HD (wut) (gran) Gaued) Grard) Ceon®) CGns*) Crer®) Coe TLL Pl TL Lis LL | eer
Figure 3-1 PT-805 Keypad
-14-
|
{ i
JTi bi bt di Pi dt bi did ld tb bib bd td
Page 19
3.2 Using the Keypad
The PT-805 keypad consists of control keys, function keys, letter keys, and numeric keys (see Figure 3-1). All keys except [ON/OFF] will produce a sound (tone) when pressed. The operation of these function keys on the keypad is described as follows:
3.3. Control Keys
There are three control keys, [ON/OFF], [SHIFT], and [CAPS]. Their function are :
[ON/OFF] Pressing the [ON/OFF] key when the PT-805 is off causes the LCD to display an initial message, followed by a ">" ready prompt. An "OFF" condition occurs when:
@ The [ON/OFF] key is pressed while the terminal is ON
@ The batteries are removed
@ The battery voltage is exhausted beyond the low voltage cut-off point.
@ The auto power off function is enabled and time out results without any keys being pressed or bar code data input.
The contents of CMOS RAM, data and programs are protected by backup battery when the PT-805 is turned off.
[SHIFT]
The [SHIFT] key toggles the keypad between the selection of upper right and the lower left functions on the keys of the keypad. Once the [SHIFT] key is pressed, the keypad will change from a normal state to a shifted state and vice versa. In the shift function, the secondary function of the keys are permitted and the cursor on the LCD will be displayed as a flashing black block, "g” Table 3-1 gives the keypad function in various modes, some keys, such as [ENTER], have the same usage in both normal state and shifted state.
[CAPS] The [CAPS] key toggle the keypad between the selection of upper and lower case letter keys. The [CAPS] only has an effect on the letter keys (see Table 3-1).
-15-
Page 20
Table 3-1 Keypad Functions
KEY [SHIFT] [SHIFT & CAPS} INPUT A a XRANS B b CALCU Cc c STATU D d EDIT E e INS F f RPL G g DEL H h + I i
- J j
* K k
/ L 1
$ M m ; N n
: O ) CLEAR P p 7 Q q 8 R r
9 S s
4 T t
5 U u 6 Vv Vv
1 WwW w 2 xX x
3 Y y 0 Z A < % % > # #
. BS BS SP SP SP ENTER ENTER ENTER EXIT EXIT EXIT