The text of a manual · part 1 of 7
PT-805 User's Manual, pages 1 to 10
Pages 1 to 10 of 70
The original document is the PDF (2.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the Unitech PT815
Page 1
~PT-805
USER’S MANUAL
§BGO0E HEQOOE HOGOON oi
September, 1994
Rev. 1.2
Page 2
Note:
Your PT-805 is installed with a rechargeable NiCd battery pack in its battery compartment.
The battery pack has been fully discharged prior to shipment. Please refer to the procedures below for the first time installation.
Procedures:
1.
3.
4.
Remove the hand strap retainer 5. at one end to provide access to the battery cover.
Remove the battery cover on the underside of the PT-805.
Remove the main battery pack from the PT-805.
Set the Lithium battery backup
7 switch to ON.
4
/
/)
ON
<<
OFF ,
Insert the main batteries:
@ NiCd battery:
First, plug the charge connector of the NiCd battery pack to the PT-805, (See figure below). Then place back the whole pack inside the compartment. (reversing step 3).
‘Replace the battery cover.
(reversing step 1). Replace the hand strap retainer.
If you are using NiCd pack, charge the NiCd batteries for 14 - to 16 hours., -
Page 3
TABLE OF CONTENTS |
Chapter1 Overview
1.1 Read This First... scsesceecesessesecseeeeessssecsecsesensensats 1 1.2 Features of the PT-805 000... eeeececceeecceseseeseseeseeneensessacseees 2 1.3 Application Development Environment................:cccceeeees 4 1.4 Conventions Used..............:eccssssseccetecneeseeneeceneesssnensensesenssnees 5
Chapter 2 Installation
2.1 Battery Comsiderations.................ccccssccsssssssesseescecsssenseseeenes 6 2.2 Battery Installations............0......cccsssssesscceeeeceeceseeeeesecereenesaes 7 2.3 Type of Batteries.............. cece ceeseceseenssesssereasentceeseceenasenes 9 2.4 Backup Battery.............ccccccssccssscssesssecsssssseesseesecessesereseevees 10 2.5 Low Battery Indication...0.........esccccsccseesesecscctcssesseseneees 10 2.6 Battery Replacement.....0........cccceececesseesseteeeeeeeeenees aseeaeees 11 2.7 Recharging the NiCd Battery Pack..00...0.....cccccseseesseeeees 12 2.8 Storage and Safety Precautions.............0cccccscsscsessssseeeeees 13
Chapter 3 Input Method
3.1 A Look at the PT-805...........cccccscccssssssscsseeessessssecessseeeeees 14 3.2 Using the Keypad.................cccssssesssesssessseessesseceeesssenseeeneens 15 3.3 Control KeyS............cccccssscsssccsscessccssecssscesecsnsesnsessceseeeneseeees 15° 3.4 Function KeyS..........cccccccssccssccsetecssecsesessesesecsseessessesenesseeets 17 3.5 Alphabetic Keys and Special Character Keys...............000 17 3.6 Numeric and Arrow KeyS..............ccccsscsssssscessesescseseeseeseeens 18 3.7 Connecting a Wand to the PT-805..0........ ec cecccseeseeeseeees 18 3.8 Connecting a Laser Scammet...............ccccesesceeeeseeeeteeeeaees 19
Chapter 4 Resident Operating Program(ROP)
4.1 Introduction... eee ssecsceereeseeseseesetscrsensseesenessseeeeeees 20 4.2 System Reset PT-805 and Enter Diagnostic.................00 22 4.3 Power On the Terminal... cece ee cecsceeeeeeeeeseeeteceeeenns 22 4.4 Ready Mode... cssecscestecsscssecsscsesrscrecssessssessssssseesees 23 4.5 INPUT Function... cecccsscseesecescsssssscnscnecneesssseseasees 25
4.5.1 Entering Data... eesccseccecscesseecetseeeeneesasessees 28
4.5.2 Editing Data... ceecesseeseeeseceseseseceesereseeeeneee 29
Page 4
4.5.3 Forms Created from Job Generator...................::00 31
4.6 STATUS Funnction.............c:ccccceceecesceeesscsccsssscssonscasseseestes 33 4.7 XRANS Function. ............ceeccceeeeseesseeeeseessnesscaecnseeesaronsees 33 ATA SOmd oo. ccccccceccesseesecneeeteeeeecsessessecsssssesnenessesseeeaees 33 4.7.2 RECEIVE.........cccccecsncccercectsecesseeecnsesentescssesesesseseeeeseeens 34 4.8 Supervisor Mode.............cscscssessssseeessceeereesesnsesssensenenees 35 4.9 SETUP Function. ...............ccccscceesecceecessceseossesssessssosesssseeenes 35 4.9.1 Auto Boot Setting... ese sstcerevsesssseronseeneees 37 4.9.2 Date & Time Setting... ccc sesceeeeseeteeteenees 37 4.9.3 Communication Parameters Setting...................006 38 4.9.4 Bar Code Setting... cc cccsssssssesssseesteneeseeneenees 42 4.9.5 ROP Data Format Setting.................:cescssseseconeeeseves 43 4.9.6 Beeper Volume Setting.......0......ccccccscsseeeseeeeteenees 49 4.10 PURGE Function. ...........0...cccccsccssessessessseesesssevsecsssseesesens 50
Chapter 5 Interfacing And Communications
5.1 Interface Requirement...............:cccccscecsreseceseneeeeeneensenes 51 5.2 Communication Software................cccsesscccccesssssersseeeeseessenes 54 5.3 Communication Data Format and Protocol................:006 54
Chapter 6 Built-In Keyboard Wedge
6.1 Installation. ...............:ccccccccseseseseeeccseseneesssesceessesseasessasesengs 57
6.2 Uploading Data to PC/AT or PS/2.........ccccssesssesseesseresesenees 58 Appendix :
Appendix A : Built-In Diagnostic Program...............ccsesesee 60
Appendix B : Error MEeSSages............cscscsseseeseeestetseteneesenenes 62
Appendix C : Specifications..............cccccseceecesereeeteneeereeeeeenenes 65
Appendix D : Pin Assignment of ConnectoTS............:ceees 66 Trademark Acknowledgments:
e Microsoft and MS-DOS are registered trademarks of Microsoft Inc.
e IBM, IBM PC, PC/AT and PS/2 are trademarks of International
Business Machines Corp. e Unitech and PC-WAND are registered trademarks of Unitech _
Electronics Co. Ltd.
Page 5
Chapter 1 Overview
1.1 Read This First
To prevent injury to personnel or damage to the PT-805 equipment, warnings and cautions are included in the appropriate sections of this manual.
Warnin Warnings, as presented in this manual, are shown as:
A WARNING is an operating procedure, practice, condition, or statement which, if not strictly observed, could result in damage to the equipment.
All warnings contained in this manual should be read and understood by the user prior to handling or operating PT-805 equipment.
Do Not Repair Or Adjust Without Supervision Equipment that is powered up should not be repaired or adjusted without supervision. At this time proper safety precautions should be observed with the PT-80S, as with all electrical equipment.
Intended Readership This Manual is intended to serve as a complete reference manual for systems managers, application developers, and operators. . The reader may only read the required chapters according to his/her requirements. However, in order to use the unit in the proper way every user should read chapters 1 and 2 .
Page 6
12 Features of the PT-805
The PT-805 Portable Terminal is a rugged, compact and lightweight handheld data collection device that offers many features for efficient bar code reading and keyboard data entry. The PT-805 is not only a portable data collector but it can also be used as a PC/AT or PS/2 keyboard wedge. A keyboard wedge is a device used in conjunction with a keyboard to enhance data entry or control of the computer. The PT-805 is ideal for a wide range of data management applications.
l
HEBEOO808 ERIE O0808 LEREOG8es HHG0008
SCANNER PORT RS-732 PORT
Figure 1-1. PT-805
Hardware SMT ( Surface Mounted Technology ) Rugged and Durable Design 64KB to 256KB user's RAM memory 64KB ROM 2 line x 16 character Liquid Crystal Display (LCD) Real-Time Clock Removable Batteries - 4 AA-size Alkaline Batteries - Rechargeable NiCd Battery Pack @ Recharging circuit of NiCd battery pack with protection from accidental charge of Alkaline batteries @ Onboard Lithium battery for data retention * A Bar Code Scanner Input Port
-2-
Page 7
@ ARS-232 Port ® Built-in PC/AT, PS/2 keyboard wedge function to upload data directly to PC or PS/2 through keyboard port Software @ Resident operating program (ROP) @ Auto executes user’s program when power is turned on @ Decoding software for all major bar code symbologies: - UPC-A, UPC-E - EAN-13, EAN-8 - Interleaved 2 of 5 - Standard Code 39 - Full ASCII Code 39 - Codabar - MSI - Code 128 Low power monitor for main battery and backup battery Auto power off function Embedded system diagnostics, data entry application and bar code decoding software @ Automatically accepts barcode input from Wand, CCD or Laser scanner @ Audio buzzer for feedback of key-pressing and barcode reading @ PC keyboard interface driver
The PT-805 operates on a rechargeable Nickel Cadmium (NiCd) pack or disposable Alkaline batteries. Data can be input through bar code reading or keypad input and stored in RAM memory, backed up by an internal Lithium battery to prevent loss of data for up to 8 months when the main batteries are ‘ removed or replaced. Section 2.3 Type of Batteries contains battery information and should be read prior to operating the PT-805.
The Display and Keypad The large Liquid Crystal Display (LCD) of the PT-805 can display 2 lines by
16 characters per line for a total of 32 characters. The colorful and versatile keypad supports special characters, upper/lower case letters, user-definable function keys, and numbers.
Data Entry Data can be entered through the alphanumeric keypad, or via bar code input devices ( Wand, CCD or Laser diode scanner ). The beeper signals to the operator when a bar code is successfully read or a key is pressed.
Bar Code Input Capability The PT-805 supports bar code scanning input and automatically discriminates bar code symbologies. It reads UPC-A, UPC-E, EAN-13, EAN- 8, Interleaved 2 of 5, Standard Code 39, Full ASCII Code 39, Codabar, Code
-3-
Page 8
128 and MSI. Each bar code symbology can also be individually enabled or ’ disabled. ,
Transmitting Data Files The terminal can communicate directly with other computers and can upload and download ASCII or non-ASCII data files. Data files are transmitted between the PT-805 and a host computer by the RS-232 interface or a Modem. Chapter 5 provides the details for interfacing the PT-805 with other systems. PT-805 also can upload data to PC/AT or PS/2 as a Keyboard Wedge. ;
1.3 Application Development Environment
Resident Operating Program (ROP) The ROP is a Resident Operating Program in the PT-805 which consists of a system kernel, I/O drivers, and a built-in data-entry application generator. Through use of the ROP the user can define data collection applications by using the keypad of the PT-80S. For a detailed description of the ROP, please refer to Chapter 4 Resident Operating Program (ROP). More complicated applications can be created by using the Job Generator program.
Job Generator
The Job Generator is an MS-DOS or PC-DOS based application program generator. Users can create their own applications by using Job Generator with a Personnel Computer and then downloading the generated JOB program to the PT-805. A customized data collection program can be created through the supplied macros. The generator will translate it into a data collection application ready to be loaded into the PT-805 terminal. An operator can edit, erase, review, and modify the built-in operations and enable a variety of terminal operations. After collection, the data can be uploaded to the PC for further processing. For more detailed information about Job Generator and the associated macros, please refer to the separate Job Generator user’s manual.
Related Publications Other documents published by Unitech Electronics Co.,Ltd. directly relate to using the PT-805 are:
Job Generator User’s Manual
Page 9
1.4 Conventions Used
The following conventions are observed throughout this manual.
Displayed Messages Displayed messages are shown in the same format as they are displayed on the terminal screen. For example,
PT805 256KB V1.00 >a
Command Syntax Command syntax is given in a format useful to performing the task.
Keypad Keys References to specific keypad keys are shown with the name of the key enclosed in square brackets, For example, Press [ENTER] means to press the key on the keypad that is labeled ENTER. In some cases, “ or CTRL is used to represent the CONTROL key of a PC .
Page 10
Chapter 2 Installation 2.1. +‘ Battery Considerations
PT-805 is operated by battery power and there are two separate battery power sources for normal operation and memory backup. The main power source can be provided by using a rechargeable NiCd battery pack or 4 AA-size ordinary batteries, placed in the main battery compartment. High capacity Alkaline batteries are recommended for use as the 4 AA-size batteries. A Lithium battery is used to backup the system real time clock and the contents of the RAM memory if the main battery is discharged or removed.
The power circuit of the PT-805 is designed, in an effective way, to provide the user with a data loss-free environment. The Lithium battery can supply the power for up to 5 years before losing its capability and the power consumption required for backup is very little. However, it may be necessary to replace it in 8 months if the user does not use the power properly.
The power of the Lithium battery is only consumed when the main power source is not available, such as if the main battery is removed or the main battery power is discharged. So if a NiCd battery pack or 4 AA-size batteries are put in the main battery compartment, power is provided to backup the RAM memory and system real time clock, which effectively puts the Lithium battery in a standby condition. The power circuit of the PT-805 monitors the voltage level from the main power source and automatically connects the Lithium battery for backup once it has detected that no power is coming from the main power source. Under these conditions, the life of the Lithium battery would be 8 months. Therefore it is highly recommended that the main battery always be kept inside the unit and fully charged.
In the event a PT-805 may not be used for a period of time ( for instance 3 weeks or longer ) and the main battery is taken out, it is also recommended that the Lithium battery should be physically disconnected to prevent its dissipation by setting the switch right above the main battery compartment to the OFF position. However, all data contents will be lost in this case.
After unpacking your PT-805, to prepare the PT-805 properly before use, the user must follow the special procedure and notes described below.