3.4 Function Keys There are nine fixed function (non-programmable) keys in the PT-805 :

[EXIT] Whenever the [EXIT] key is pressed, the terminal exits the current operation and returns to the last function. For example, in the Input Mode, pressing the [EXIT] key will return the PT- 805 to the Ready Mode.

[INPUT] Press this key to enter Input Mode, which allows you to input and edit collected data.

[XRANS] | Press this key to enter Communication Mode. This allows the PT-805 to transmit collected data to the PC or to receive a Job Generator Program from a PC.

[CALCU] Press this key to enter Calculator Mode. Four basic arithmetic operations ( +, -, * / ) are provided. The [(NO)] key will clear the display.

[STATU] _ Press this key to enter Status Checking Mode, which permits the verification of free memory and displays how many data records for each form.

[EDIT], [INS], [RPL], [DEL] are provided to view and edit the data in the memory after entering the input function. For a more detailed description, please refer to Section 4.5.2. Editing Data.

[CLEAR] Press this key to clear the current input buffer all data and set the cursor back to the original position.

3.5 Alphabetic Keys and Special Character Keys The letter keys are data entry keys. There are 26 of them, one for each letter of the alphabet. First, you must press the [SHIFT] key to access the letter keys. The upper case or lower of each key depends on the state of the [CAPS] key. The following are returned (see Table 3-1):

-17-

Page 22 read from a scan by OCR; it may hold reading errors

@ An upper-case letter (default).

@ An lower-case letter when the [CAPS] toggle is ON.

@ A special character, like "+", "-" ,"*" etc., when the [SHIFT] toggle is OFF.

3.6 Numeric and Arrow Keys

The numeric keys [0] - [9] are larger for easy data input. The two arrow keys [<] and [>] are used to move the cursor when editing data or setting functions. :

3.7 Connecting a Wand to the PT-805

To connect a Wand to the PT-805; connect the Wand connector into the scanner port on the bottom of the PT-805 (see Figure 3-2). The PT-805 can auto-discriminate the type of scanner from Wand, CCD scanner or Laser scanner.

SCANNER PORT Figure 3-2 Connecting a Wand to the PT-805

After connecting the wand to the PT-805, power up the terminal. The following label can be read for testing:

VWAINID

-18-

Page 23 read from a scan by OCR; it may hold reading errors

3.8 Connecting a Laser Scanner

The PT-805 can use the Laser diode scanner without an external power source being required. To connect the Laser diode scanner to the PT-805, snap the Laser scanner connector into the scanner port on the bottom of the, terminal (see figure 3-3 ). The PT-805 can auto-discriminate the type of scanner ( Wand, CCD scanner or Laser scanner).

SCANNER PORT

Figure 3-3 Connecting a Laser Scanner to the PT-805, After connecting the Laser scanner to the PT-805, power up the terminal. * Read the following label for testing:

Hi

LASER :

Page 24 read from a scan by OCR; it may hold reading errors

Chapter4 Resident Operating Program(ROP)

4.1 Introduction

The Resident Operating Program (ROP) is a program stored in the PT-805 ROM. The ROP serves as an operating system program, managing the PT- 805's memory, downloading program, and resident application program. Through the ROP, the user can quickly develop applications for using the PT-805 keypad. In general, the ROP provides the following functions to the user:

@ A programming mode which allows the user to define the data collection application.

@® Execution of the defined application.

@ Receiving a generated program from the Job Generator.

@ Sending data to the host.

® Displaying the status of the terminal.

@ Arithmetic calculation.

This chapter will give detailed information about using the built-in application program. Knowledge of the general logic flow for bar code processing is assumed.

Operating Flow of the ROP Figure 4-1 shows the operating flow of the ROP. Each block indicates a function or a "state" that the PT-805 performs. The functions will not be discussed until later in this chapter. As figure 4-1 indicates, by pressing the [ON/OFF] key the PT-805 is powered on, and by pressing the [INPUT] key the prompting message “Input ROP? (Y/N)” is displayed on the LCD screen. Pressing [(YES)] key will cause the PT-805 to go to the ROP input data function.

- 20-

Page 25 read from a scan by OCR; it may hold reading errors

[SHIT] + PI petit comecs om) (aE

(er (Sz) SE) [=m] [we

2G eles(S) ey

Figure 4-1 System Functions of the PT-805 ROP

-21-

Page 26 read from a scan by OCR; it may hold reading errors

4.2 System Reset PT-805 and Enter Diagnostic

There may be an occasion when you want to completely clear out everything that you have stored in the RAM of your PT-805. However, this can be a drastic measure if done erroneously. Consequently, the PT-805 will ask for verification.

To reset the PT-805, turn off the terminal, press the [EXIT] . [P] and [ON/OFF] keys simultaneously, and then turn the terminal ON. The screen will display the following message:

System Reset ? (Y/N)

Pressing [(NO)] will not reset the data in the PT-805. Pressing [(YES)] will erase all the information stored in the PT-805 RAM, including files, programs, and parameters. Then the PT-805 will ask if you want to run the Diagnostic function or not. For more detailed information refer to Appendix A. Built-in Diagnostic Program.

CAUTION Data will be lost after SYSTEM RESET and some of the data and programs in the RAM memory may not be recovered.

4.3 Power On the Terminal

When you first switch on the PT-805, the screen will display a series of status messages indicating the version number, total RAM, and total available

PT805 xxxKB Vn.nn

- 22.

Page 27 read from a scan by OCR; it may hold reading errors

- On the display, the first line shows the model number, how many kilobytes of total RAM (i.e. 256KB) and the version number (e.g. V2.00). The amount of RAM will depend on the PT-805 model (see ordering information).

Low Voltage Cutoff Point When pressing the [ON/OFF] key the terminal may not be switched on if the batteries are below the low-voltage cutoff point. Replace or recharge the batteries at this time. Another possibility is that the terminal may be powered on, but the screen is flashing. This indicates that the batteries are low and the device can be operated only until the cutoff point is reached. Both of the aforementioned situations will not result in data loss from the memory since a back-up battery is in the PT-805 as well. For detailed information about batteries, see Chapter 2. Installation.

4.4 Ready Mode

The last line on the display shows the prompt, ">" which indicates that the terminal is in the "READY" mode. At this time the terminal can accept characters from the input devices (keypad or Wand), show the LCD display only, transmit out data to the serial port and respond to the serial port. The functions of ready mode are as follows:

Read Labels in Ready Mode In ready mode the labels can be read by using wand or a scanner. To test your terminal, scan the following label:

UNITECH

-23-

Page 28 read from a scan by OCR; it may hold reading errors

If the PT-805 is connected to a terminal or a host, the label will be sent to the host through the RS-232 interface provided the proper software is installed on the terminal or host.

Using the Keypad in Ready Mode The keypad can also be used as an input device. Alternately, the keypad can be used in conjunction with the ROP or Job Generator.

Transmitting Data in Ready Mode In ready mode, labels or characters scanned/read from input devices of the

PT-805 will be sent out via the serial port located on the bottom of the terminal (Refer to Chapter 4, Interfacing and Communications). In ready mode the PT-805 serves as a dumb terminal to transmit data to a personal computer.

Receiving Data in Ready Mode Data can be received from the serial port and displayed on the screen. Again, the user should know that the communication parameters must be set properly before receiving data.

Receiving Commands in Ready Mode The PT-805 can be controlled and programmed alternately from a PC or

Host. Commands can be sent via the serial port. Some commands, called host commands, are provided to control the terminal in ready mode. This gives flexibility for programmers to write their own applications and controls by using the computer. Table 4-1 gives a summary of the host commands.

Table 4-1 Summary of Host Commands

Host Commands Response of the PT-805

<ESC> <I> <form name> <CR> INPUT the form specified in <form name> directly.

<ESC> <P> <form name> <CR> PURGE the data specified in <form name> firectly.

<ESC> <X> <form name> <CR> SEND the data specified in <form name> directly.

<ESC> <V> <CR> SEND version number.

<ESC> <D> <CR> Prepare to RECEIVE a job generated from Job Generator.

el

For example, to command the PT-805 to send data to the computer, send to the PT-805 the command sequence, <ESC> <X> <form name> <CR>, where

- 24.

Page 29 read from a scan by OCR; it may hold reading errors

<ESC> is the ASCII code 27, <X> is the letter "X", and <CR> is the ASCII code 13. The <form name> specifies the collection application sent. For instance, the "ROP" is used as the form name for the built-in application. The following table shows the activity when host commands are sent to the PT- 805:

COMPUTER PT-805 DESCRIPTION <ESC>XROP<CR>, - Request data in the ROP form. < - <DATAPACKET> PT-80S5 sends out the ROP’s data (format is described in Section 5.3 Communication Data Format and Protocol) sO

In fact, host commands are designed to correspond to each of the functions in the ROP. These functions are described later in this chapter.

4.5 INPUT Function

The INPUT function is used to select and execute the data collection programs. A ROP program can be created using the “Set Data Format” in SETUP of supervisor mode. Other programs can be created with the Job Generator program and downloaded to the PT-805. A program is composed of the following procedures:

Prompting Message Data Input

Data Checking Data Format

These procedures are continued until the job is terminated by the operator. The INPUT function also allows for the data to be edited. This includes data insertion, deletion, or replacement. Each task is described below:

Prompting Message The prompting message gives the operator directions as to the data to enter.

Messages like "ENTER PRICE", “ENTER SERIAL NO.", etc. aid in the data collection process by organizing the data and allowing even a novice to quickly collect data.

Data Input Data can be input by a wand, scanner or the keypad.

- 25 -

Page 30 read from a scan by OCR; it may hold reading errors

Data Checking In order to insure the accuracy of the data collected the ROP has the following checks available for users:

@ Bar Code Discrimination @ Length of Data @ Picture or Mask Check

Many bar codes can be interpreted by the PT-805. To increase the accuracy of the label reading, it is best to allow only the specific bar code used to be read.

Field length can be checked by defining the minimum and maximum data length. This will reject labels with incorrect lengths. This is especially convenient for bar codes like Interleaved 2 of 5, which may read in the wrong width.

The picture or mask check rejects any data that does not conform to a defined “picture” or "mask". In most applications labels have a fixed format. For example, if a mask was defined where the first three characters are numbers, the fourth character is a letter, and the last three characters are numbers, then 123A456 would be checked and accepted while ABC9DEF would be rejected.

The picture or mask definition is covered in Section 4.9.5 ROP Data Format Setting.

Data Format

In the ROP, data entered is stored in RAM with a specific file format or form. A form is defined as a series of control parameters and collected data. The control parameters include the prompting message, checks, delimiters, etc. The data is composed of records with each record separated by a record delimiter. A record can be composed of multiple fields with each field separated by a field delimiter. Record and field delimiters are chosen according to the after collection processing application. Figure 4-2 shows a sample record.

Field #1]F|Field #2|F|.... Field #n[R

Figure 4-2 Composition of a Record

Where n: can be up to 16 fields F field delimiter ( [,] , [;] , [SPACE] and none )