Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 3 of 4

PT600 Portable Data Collection Terminal User's Guide, pages 17 to 24

Pages 17 to 24 of 31

The original document is the PDF (375 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Unitech PT600

Page 17

Chapter 2 2.1

Power System

Power Supply

Main Power The PDT is operated by a rechargeable NiMH battery pack with two AA size 1.2V 1500mAH capacity or two AA alkaline batteries for the main power source. Back up Power An onboard 3V 190mAH Lithium battery (CR2032) is used as the secondary power source to back up the data in RTC (real time clock chip) and RAM memory to provide users a data-loss free environment. Normally the PT600 gets power from main power source to back-up RTC and RAM and puts the Lithium battery in standby state. When the main power source is removed or below the level to back-up the RAM and RTC properly, the power circuit of the PT600 automatically switches to the Lithium battery for back up. It is recommended that the main battery be always placed inside the unit with enough capacity for back-up purpose in which case the Lithium battery can supply the power for up to 5 years before consuming all its capacity up.

2.2

Power Low Indication

Main Battery When the main power source reaches the battery low condition, a warning message as right will be shown on the LCD when PT600 is powered on or a battery low icon sign will emerge on the right sidebar of LCD.

- 14 -

! WARNING ! MAIN BATTERY VOLTAGE LOW

Page 18

When the main battery low condition occurs, the main battery can continue to supply power for about 10 ~ 30 minutes, however the unit may reach the system power cutoff point and automatically turn itself off. Meanwhile the unit continues to back-up the data contents in RTC and RAM, but it cannot be powered up until the batteries have been recharged or replaced. Lithium Backup Battery When the Lithium backup battery doesn't have WARNING ! enough capacity to back up the system, the !LITHIUM BATTERY message as right will be shown on LCD when LOW the unit is powered on. In this situation you should upload your data from the PDT immediately and replace a new Lithium battery.

2.3

Battery Replacement

Main Battery 1. Make sure the unit is turned off. 2. Turn over the unit. Slide tab from right to left (see illustrations in next page). 3. Slide the main battery pack from battery compartment. 4. Insert the new main battery packet:

- 15 -

Page 19

Remove battery pack

Remove backup battery

Use nipper to pick up cover from screw holes for battery change.

Before change Lithium battery. Note : backup Your data first.

Lithium Back up Battery 1. Refer to the procedure in previous paragraph, un-screw the backup battery cover and as illustration above to remove the lithium battery. 2. Insert a new battery into the holder with correct orientation. 3. Put the battery cover back.

*

Make sure to back up your data in PDT before making the replacement the lithium back up battery.

- 16 -

Page 20

2.4

Recharging the Battery Pack

When the PDT shows “Main battery low” message or sign , the battery pack in PDT needs to be recharged. There are two ways to charge the battery: regular and quick charging as shown below. Regular Charging

Outer shell Negative(-)

Inner shell Positive(+)

AC to 9V DC Transformer

Plug one end of an AC-9VDC power adapter into the DC-jack of RS232 cable and the other end into a wall outlet. The battery pack will be fully recharged after 14~16 hours. Quick Charging with PT016

Charge Battery

AC to 12V DC Transformer

Outer shell Negative(-)

Inner shell Positive(+)

Connect power adapter to PT016 and insert PDT into the chamber of PT016. The battery of PDT can be fully charged in about 2.5 hours and the status of battery charging is indicated by the LED on the front panel of PT016.(please refer to PT016 manual for detail information. )

- 17 -

Page 21

Charging Considerations It is important to consider the surrounding temperature whenever you are charging the NiMH battery pack. The process is most efficient at normal room temperature or slightly cooler. It is essential that you charge batteries within the stated range of 32°F to 113°F (0°C to 45°C). Charging batteries outside of the specified range could damage the batteries and shorten their life cycle. Effects Of Overcharging Batteries Overcharging may occur when a NiMH rechargeable battery is charged in regular or quick charging rate after it has been fully charged, but there is no risk of overcharging while charged in trickle charging rate. If NiMH batteries of PDT are charged by a power adapter plugged directly to its DC jack for too long, they can sustain a temporary reduction of capacity due to overcharging. A battery left to charge for several weeks may appear to have minimal capacity. This type of failure can be remedied by temporarily depleting the battery of its power and recharging it to rejuvenate it. This condition can be prevented by avoiding overcharging for long periods of time or always using PT016 to charge the batteries of PDT. The PT016 starts the charging process in quick charging rate and switches to trickle charging rate when it detects the battery is fully charged.

2.5

Storage and Safety Precautions

Batteries should be stored in an open circuit condition and placed where there is no risk of accidental shorting or other damage. Although charged NiMH batteries may be left unused for several months, their capacity may be reduced due to back up and internal resistance. If this happens they will require recharging prior to use. NiMH batteries may be stored at temperatures between -4°F and 158°F (-20°C to 70°C), however they may be depleted more rapidly at the high end of this range.

- 18 -

Page 22

Chapter 3

Operation

The system of PDT may operate in various modes for different purposes. The figure below shows the operating flow of the PDT. press and hold down CMD and <− keys then press PWR OFF press PWR enter program name then press ENTER

APPLICATION mode

PT600 V1.00 MEM 512KB > press CMD (for two seconds)

RUN command press press EXIT

2

<<START MENU>> 1.SUPERVISOR 2.WARM START 3.COLD START press 1 then

1.RUN 3.COM 5.ERA 7.CPY

2.TER 4.DIR 6.TYP 8.SET

Alpha

SUPERVISOR mode

USER mode

System configurations are categorized in two groups, users can select “8.SET” command in User mode to set general system configurations or enter Supervisor mode to set advanced system configurations. The Supervisor mode is also protected with password checking to prevent unauthorized personnel from changing the system configuration. (for PT600 detail information please refer to PT600 Technical Binder)

3.1

Ready Mode

The PDT performs a Power-On-Test and Warm-Start when it is switched on. After the Warm Start, the system enters Ready mode and shows the Ready mode prompt. - 19 -

Page 23

Ready mode prompt PT600 Vx.xx MEM 4608 KB >

The first line indicates the model code and version number (e.g. V1.00). The second line shows the size of the total installed RAM (i.e. 4608 KB). The third line prompts a ">" which indicates that the terminal passed the Power-on-test and is ready to be used.

3.2 User Mode and System Commands There are eight system commands: RUN, TER, COM, DIR, ERA, TYP, CPY, and SET. Each command can be invoked through menu-selection in User mode. User can press [CMD] key for two seconds in Ready mode to enter User mode. User mode prompt

Select the corresponding number, 1-8, or press [ß] and [à] to highlight a command then hit [ENT] to select a system command. Pressing the [EXIT] key (hit [CMD], then [ALPHA]) returns to Ready mode.

(1) RUN (3) COM (5) ERA (7) CPY

(2) TER (4) DIR (6) TYP (8) SET

RUN

When invokes the RUN command, the < RUN PROGRAM> system shows a screen as right and you may press the [à] key to toggle the NULL loaded program and hit [ENT] to run the program. The program may also be executed on the PDT by entering the program name directly in Ready mode.

TER

This command puts the PDT in either terminal emulation mode or FormCaching application mode depending on which function you select. Please see chapter 4 for detail on how to configure and use FormCaching. In terminal emulation mode, the PDT serves as a dumb terminal to transmit data to or receive data - 20 -

Page 24

from a Host computer. In this mode, data input from bar code reader or keyboard is displayed on screen and output to RS-232 port. Data received from the serial port is displayed on the LCD screen. Communication parameters, such as baud rate, data bits, parity, stop bits and flow control, must be set to be compatible with the destination in order to send data properly. COM

This command puts the PDT in Kermit server mode. The following indicates the available Kermit commands at the Host/PC side: Command

Description send filename

Send a file from the Host/PC to PDT and store it in the PDT's RAM disk.

get filename

Get a file from the PDT to the Host/PC disk.

remote dir

List files of the PDT’s RAM disk.

remote del filename Delete a data file stored in the PDT’s RAM disk. Make sure set the PDT communication parameters to match the host/PC system before proceeding data communication. Hit [CMD] then [ALPHA] keys to return to the Ready mode. DIR

This command shows the files in the RAM disk with the following information: n The list of file names stored in the RAM DISK. n The size of program execution area. n The amount of free RAM DISK space left.

ERA

This command deletes a file from RAM < ERASE FILE > disk of PDT. After the file has been SCAN.EXE deleted, it can not be recovered.

- 21 -