Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 4 of 4

PT600 Portable Data Collection Terminal User's Guide, pages 25 to 31

Pages 25 to 31 of 31

The original document is the PDF (375 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Unitech PT600

Page 25

TYP

This command dumps the content of a < TYPE FILE > file on the PDT's LCD. The content of the file will be displayed 128 (16 SCAN.DAT character x 8 line) characters at a time. Press any key to show the next page or hit [CMD] then [ALPHA] keys to return to User mode prompt. If you try to display a program or binary file, you may only see unintelligible characters.

CPY

This command allows users to make copy of data from a source device to a destination device. The source device may be a file, COM(serial input), CON(keyboard), and the destination device may be a file, COM(serial output), CON(LCD display). Source file1 file1 file1 COM CON

SET

3.3

Dest. Function file2 copy file1 to file2 COM output content of file1 to serial port CON output content of file1 to LCD file2 input data from serial port and store in file2 file2 input data from keyboard and store in file2, press [CMD] and then [ALPHA] key to end the data input

This command allows users to set system date and time, assign laser or pen scanning feature and enable to display power-on logo (see next section).

Configure the Terminal in SET command

There are three categories of general system <SYSTEM SETUP> configuration available in SET command. Select 1.DATE & TIME the corresponded number, 1-3, to set system 2.SCANNER 3.DISPLAY date/time, assign scanning feature and enable power-on Logo display. Hit [CMD] then [ALPHA] keys to return to User mode prompt.

- 22 -

Page 26

1. DATE & TIME:

set system clock/calendar

When selects “1.DATE & TIME” in SET DATE-TIME SETUP command menu, the screen as right will be 1998/01/01 shown on PDT’s LCD and let you set the 08:00:00 system date and time of Real Time Clock chip (RTC). The system date and time can be retrieved in application and used as time stamp for data collection. The second line shows the current date in the format YYYY/MM/DD (year/month/day). If you want to reset the system date to January 1, 1997, then enter[1][9][9][7],[0][1],[0][1]. Or press [ENT] key to skip the system date setting. The third line shows the current time. The way to set system time is similar to set system date described above. The format of system time is expressed in 24 hour of HH:MM:SS (hour:minute:second). 2. SCANNER: set reading mode of built-in The system software of PDT decodes all major bar code symboloies including Code 39, Code 128, Codabar, Code 93, I25, EAN, UPC, China Post code, etc. Use the [à ] key to toggle among selection in each category, then press [ENT] to confirm. SCANNER Enable / disable bar code decoding. PEN SCAN KEY When pen scanner is used on PT600, user can setup whether pressing trigger key to enable pen scanner. If ENABLE is selected, user must press and hold down trigger to scan barcode label. If DISABLE is selected, user can directly scan barcode label without pressing trigger key. Enable / Disable 3. DISPLAY: Enable/disable power-on logo display ENABLE Show system logo when power-on. DISABLE Do not show system logo when power-on.

- 23 -

Page 27

3.4

Upload/Download by ESC Command

The way to make file upload/download by Kermit server described in section 3.2 will need the operator to set the PDT to Kermit server mode by invoking user command “3.COM” in User mode or calling system function in application program. The hardware and software of PDT is designed that the unit can be waken up (turned on) by input from serial port. Besides the previous method to upload/download file, the PDT can also be instructed to process the data communication by remote ESC commands through built-in MULTI communication protocol.(please refer to PT600 Technical Binder for detail information) After linking the PDT to a PC/host through RS232 interface a communication program running on host first sends a few of dummy bytes to the PDT and delay for about 500 mini-second to remote wake up the unit if it is off. Then the program can send out a data pack of a remote ESC command that matches the MULTI protocol to the PDT and instruct the terminal for certain process. For instance, the terminal will automatically execute the system routine to upload a file after receiving the valid “File upload” ESC command. Meanwhile the program running on the host should follow the control flow of MULTI protocol and process to receive the data. For detailed description of each ESC command and protocol, please see the PT600 Programming Reference Manual.

- 24 -

Page 28

Chapter 4 Built-in Application: FormCaching The system of PDT includes a built-in application, FormCaching, that allows user to create a data entry application by specifying field prompt, type, length, input method and delimiter,...,etc. without writing program and loading to the terminal.

4.1 Specification of FormCaching DATA FIELD DEFINITION: maximum field number=8

Category 1 FIELD PROMPT 2 MIN/MAX DATA LENGTH 3 DATA TYPE

Range

Description max.16 characters 1-32 set field prompting set minimum field length and maximum field length numeric data (0~9) or alphanumeric data (20H~FCH) input by keyboard only, bar code scanning only or both

1.NUMERIC 2.ALPHANUM

4 DEVICE TYPE

1.KEY ONLY 2.SCAN ONLY 3.BOTH DATA RECORD DEFINITION

Category 5 BETWEEN FIELD 6 FIELD DELIMITER 7 RECORD DELIMITER 8 DATE STAMP FIELD 9 TIME STAMP FIELD 9 FIELD DELAY

Range

Description

1.Append screen 2.Clear screen 1., 2.; 3.Space 4.Tab 1.CR 2.LF 3.CRLF specify to clear or append screen between two fields assign field delimiter

1:NONE 2.YYYYMMDD 3.MMDD 4.MMDDYYYY 5.DDMM 6.DDMMYYYY 1:NONE 2.HHMM 3.HHMMSS specify format of Date stamp

0-6

- 25 - assign record delimiter specify format of Time stamp specify time delay between each record input in second

Page 29

4.2

How to Create a FormCaching

You will need to enter Supervisor mode and FORM CACHING select “4.FORM” category in order to set the 1:YES configuration of FormCaching (refer to the 2:NO PT600 Programming Reference Manual for OTHER:EXIT how to enter the Supervisor mode). After selecting the “4.FORM” in Supervisor mode, the screen will show as above. The system will first ask user to specify four categories of the field specification including field prompt, data length, data type and device type of each data field. After completion to define all data fields, the user should hit [CMD] then [ALPHA] keys to end the setup of field specification. This step also determines the number of fields in each record and you may continue to set the rest six categories of record specification including between field, field delimiter, record delimiter, date stamp field, time stamp field and field delay. When the FormCaching application is executed, a data file named FORM.DAT will be created to store data. The system will not allow the user to redefine FormCaching if the FORM.DAT is existed. It is necessary to delete the FORM.DAT in order to change the configuration of FormCaching.

4.3

How to Run FormCaching

When FormCaching is enabled, the built-in application can be run by selecting “2.TER” command in User mode and then select “2.FORM CACHING”. The FormCaching application will follow the setting as defined to display prompting, get input and store data in the file named FORM.DAT. Hit [CMD] then [ALPHA] keys to end FormCaching and return to system Ready mode. User may use [ß] key to browse a previous data record, [à] key to step to next record, press [C] key to clear the record and then input new values of every field of this record.

- 26 -

Page 30

After collecting data, the FORM.DAT file can be uploaded to host either by invoking kermit server in User mode described in section 3.2 or remote ESC command described in 3.4.

4.4

Default Setting of FormCaching

In default, the FormCaching is initialized with settings as shown in the table below. DATA FIELD SPECIFICATION: field number=2

Category

Setting

Field #1

FIELD PROMPT ITEM: DATA LENGTH 32 DATA TYPE ALPHANUM DEVICE TYPE BOTH Field #2 FIELD PROMPT QTY: DATA LENGTH 4 DATA TYPE NUMERIC DEVICE TYPE KEY ONLY DATA RECORD SPECIFICATION

Category

Setting

BETWEEN FIELD FIELD DELIMITER RECORD FELIMITER DATE STAMP FIELD TIME STAMP FIELD FIELD DELAY

Append screen , CR NONE NONE 0

1998.10.9 edited

- 27 -

Page 31

Warning This is a Class A product in a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.

- 28 -