The text of a manual · part 2 of 4
PT600 Portable Data Collection Terminal User's Guide, pages 9 to 16
Pages 9 to 16 of 31
The original document is the PDF (375 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Unitech PT600
Page 9
Width of field in Inches/ Centimeters High Density Model ___ 2.9 In. 7.4m 2In. S.lem In 25cm Oln. Ocm ~~. / Lin o - 25 Mb : : ‘ 250m o - iMi _, : : {| 2In. e 4Mil e : 5.1em + 5 Mil o | 2.9 In. é ZS Mil e 7.4m + 100%UPC «
Olin, tin. 2in, 3in. 4In. Sin. Gln 7 In. 8.5 In. Ocm 2.5 5.1 7.6 10.16 12.7 15.2 17.8 21.6cm Typical Depth of Field in Inches/Centimeters
Width of field in Inches/ Centimeters Wide Angle Model, - 10.3 In. aT 26.2 cm | 5.0 ln 12.7 cm : | Oln. o - S My | 5.0 In. ° 15 Mil, 12.7 cm 100% | 10.3 In. 40 Mil e 26.2cm 58 Mil o Olin. Sin. 10 In. 15 la. 201n. 23 In Ocm 12.7 25.4 38.1 50.8 $8.4cm
Typical Depth of Field in Inches/Centimeters
Page 10
Diagram shown with a clip-on pen scanner
45° 45° oO
Page 11
1.2
Interface Ports
The PT600 has a RS232C serial port with miniature RJ10 connector, Communication by Infrared LED which on the left side of lower cabinet and charging pads locate on the bottom.
Pin Signal Direction Description 1 DC9 V Input External power input 2 TXD Output Transmit date 3 RXD Input Receive date 4 N.C. 5 GND Reference Ground 6 N.C. 7 CTS Input Clear to send 8 RTS Output Request to send 9 N.C. 10 N.C.
1
10
The diagram below shows the way to connect input/output devices to the PDT. RS232 cable
MODEM
TELEPHONE LINE
MODEM
RS-232 PORT
-8-
COMPUTER SYSTEM
Page 12
1.3
Using the Keyboard
The keypad of PT600 consists of 27 rubber keys, the key is used to switch on/off the unit and other 26 keys are used to control the unit and key in data. The use of keyboard is categorized to three modes: normal mode, command mode, and alpha(betic) mode. All keys except key may produce a sound (tone) when pressed. Keys of upper four rows have larger size for easier key-pressing to input numbers. [ ]
When the unit is off, pressing the key will turn on the unit. On the other hand, when the unit is on it is needed to press and hold down the key for about one second in order to turn the unit off.
[CMD]
Pressing the [CMD] key sets the keyboard to Command mode. However pressing and holding down the [CMD] key for two seconds in Ready mode will enter the User mode. In User mode, users can invoke system commands by menu selection.
[ESC]
In User mode or Supervisor mode, pressing the [CMD] key and then pressing [ALPHA] key will exit from the current operation to the previous operation.
press [CMD] press [CMD]
NORMAL mode press [ALPHA] press [ALPHA] press [CMD]
COMMAND mode press [ALPHA]
-9-
ALPHA mode
Page 13
NORMAL mode Keyboard of the PT600 is initialized to normal mode after powered on. In normal mode, the cursor is a block sign and the keyboard is mainly used to input numeric data and use F1-F4 four function-keys. The keypad layout of available keys in normal mode is shown on right picture. Enter key for next data search
Clear key for last data search
COMMAND mode Press [CMD] key sets the keyboard to command mode. In command mode, the cursor type keeps same and the keyboard is mainly used to input special characters, make hot-key function, and use F5-F8 four function-keys. The keypad layout of available keys on command mode is shown on right picture. There are three hot-key functions and the usage of each function is described below.
- 10 -
Page 14
ALPHA mode Press [ALPHA] key to toggle between normal mode and alpha mode of keyboard. In alpha mode, the cursor is an underscore sign and the keyboard is available to input upper case letters. In alpha mode, every numeric key contains 3 characters individually. Pressing the key [è]and [ç] to choose among three available characters.
For example : First press [ALPHA] to switch the system to alpha mode, the cursor type will be changed from block to underscore To enter ‘A’, hit [ç] then [7]. To enter ‘B’, hit [7]. To enter ‘C’, hit [è] then [7].
1.4
Triggering Scanner Module
The PT600 can be used with a built-in integrated laser scanner module or clip-on pen scanner module. The built-in decoder reads barcode labels of all major bar code labels. The user should keep laser window or tip of pen clean to prevent low reading rate of distorted bar code input signal.
- 11 -
Page 15
1.5
Application Development Environment
The system of PT600 provides DOS functions and device drivers for application development, including bar code decoding, keypad input, display output, serial input/output communication, real-time-clock access and power management control. The PT600 can be programmed by the high-level Windows-based JobGen Plus and DOS-based JobGen Pro program generation software. It can also be programmed by commonly used C compilers including Microsoft C, Borland C and Turbo C. An executable program generated by JobGen Pro, JobGen Plus or created by a compiler is downloaded to the unit and run on the unit.
JobGen Plus JobGen Plus is a Windows-based program generator that gives the user an ease-of-use and comprehensive terminal application developing environment. Through the use of JobGen Plus, user can design an application program for a data collection terminal by simply drawing the data collection sequence on paper, and thus, requires minimum programming skills.
JobGen Pro The Job Generator Pro is a DOS-based program generator software of the PDT. With the Job Generator Pro, users can easily create the applications by defining the data fields of a transaction and then download an executable program generated by JobGen Pro to the PT600. After data collected and processed on the PT600, the data can be uploaded to the PC for further processing. For more detailed information, please refer to PT600 Programming Reference Manual, JobGen Plus User's Manual and JobGen Pro User's Manual respectively.
- 12 -
Page 16
1.6
Optional Charging/Communication Cradle
An optional charging/communication cradle (docking station), PT016, gives users a convenient accessory for daily use of the PT600. The cradle has been incorporated a quick charge circuit that the NiMH battery pack installed in the unit along with an extra spare pack can be fully charged in about 2.5 hours. Regular charging time of the battery pack through DC power adapter is about 14~16 hours. The cradle also allows users to link the PT600 to host computer through point-to-point RS-232 or multi-point RS-422 connection for data communication. The cradle with internal modem will be available in the future. POINT-TO-POINT RS232 Connection
Spare Battery pack DC 12V
Charging and Communication Cradle
RS232 cable
PT016 COMPUTER SYSTEM
MULTI-POINT RS422 Connection DC 12V DC 12V
DC 12V
RS422 interface COMPUTER SYSTEM
- 13 -