The text of a manual · part 4 of 6
MS100 Bar Code Pen Reader, pages 31 to 40
Pages 31 to 40 of 59
The original document is the PDF (916 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Unitech MS100
Page 31
Quick Setup Bar Codes, continued UPC-A
EAN-8
Default
Default
Cut Leading Digit
Cut Leading Digit
Cut Check Digit
EAN-13
Display Version
Display Version
Cut Check Digit
UPC-E
Default
Default
Cut Leading Digit
Cut Leading Digit
Cut Check Digit
Send Check Digit
ISBN Conversion
Menu Setup
UPC-A Conversion
Factory Default
Enable / Disable
Supplemental Code
Factory Default
No
Yes
MS100 Manual
27
Page 32
Device Selection and Default
Enter Group 1
Group Default
0
Factory Default
Device ID Device Type
1
00 - IBM PC/XT 01 - IBM PC/AT, PS/2 MOD 40, 60, 80, USB etc. 02 - IBM PS/2 MOD 30 (8086) 25, 56, 70, 90
2
03 - Macintosh (ADB Port) 04 - Serial Wedge 06 - Keyboardless Wedge (PC/AT, Notebook)
3
07 - Wand Emulation (with Code 39 output) 08 - IBM 3196 / 3197 09 - IBM 3476 / 3477
4
10 - IBM 3191 / 3192 / 3270PC 11 - IBM 3486 / 3487 / 3488 13 - IBM 3471 / 3472 (3179)
5
15 - IBM 3180 17 - IBM 3151 19 - IBM 5550-5P
6
20 - IBM 5550-6P 25 - Terminal Wedge 26 - Wand Emulation (Native Output)
7
32 - DEC VT220/320/420 27 - Dorio PC Keyboard 28 - Dorio ANSI Keyboard
8
9
28
35 - Serial TTL Inverted
Exit
MS100 Manual
Page 33
Beeps and Delays
Enter Group 2
Group Default
Beep Tone: (see page 6)
0
1
0 - None 1 - Low 2 - Medium 3 - High 4 - Low to High 5 - High to Low
A1
Interblock Delay: (see page 6)
2
3
0 - 0 ms 1 - 10 ms 2 - 50 ms 3 - 100 ms 4 - 500 ms 5 - 1 seconds 6 - 3 seconds 7 - 5 seconds
A2
4 Intercharacter Delay:
5
6
(see page 6) 0 - 0 ms 1 - 1 ms 2 - 2 ms 3 - 5 ms 4 - 10 ms 5 - 30 ms 6 - 50 ms 7 - 100 ms
A3
7
8
9
MS100 Manual
Exit
29
Page 34
Keyboard Interface
Enter Group 3
Group Default
Function Code: (see page 7) 0 - Off
0
1 - ON
B1
1
Caps-Lock: (see page 7) 0 - Auto Trace (PC/AT) 1 - Lower Case 2 - Upper Case
B2
2 Language (For PC/AT): (see page 8) 0 - U.S. 1 - U.K. 3 - Swedish 4 - Spanish 6 - Italian 7 - German 9 - Alt Key Mode
3
2 - Swiss 5 - Norwegian 8 - French : - Danish
B3
4 Use Number Keypad Digits: (see page 8) 0 - Disable
1 - Enable
B8
5
6
7
8
9
: 30
Exit
MS100 Manual
Page 35
RS232
Group Default
Enter Group 4
0
Baud Rate: 0 = 300 1 = 600 2 = 1200 3 = 2400
4 = 4800 5 = 9600 6 = 19200 7 = 38400
C1
1
2
3
Parity: 0 = Even 1 = Odd 2 = Mark
3 = Space 4 = None
Data Bit: 0=7 1=8
C2
C3
4
5
6
Handshaking (for serial wedge) 0 = Ignore 1 = RTS enabled at Power Up 2 = RTS enabled in Communication
C4
ACK/NAK (for serial wedge) 0 = Off 1 = On
C5
BCC Character (for serial wedge) 0 = Off 1 = On
C6
7
8
9 MS100 Manual
31
Page 36
RS232, continued
0
1
Time Out (for serial wedge) 0 = 1 second 1 = 3 seconds 2 = 10 seconds 3 = Unlimited
C7
Data Direction (for Terminal Wedge) 0 = Send to Host 1 = Send to Host and Terminal 2 = Send to Terminal
C8
2
3
4
5
6
7
8
9 32
Exit MS100 Manual
Page 37
Scanner Port
Enter Group 5
Group Default
Terminator: (see page 11)
0
1
2
0 - Enter 1 - Return (on keypad) 2 - Field Exit or Right Ctrl 3 - None
D1
Code ID: (see page 11) 0 - disable 1 - Enable Note: This setting does not affect EAN128 Code ID. EAN128 has its own Code ID setting on page 11.
D2
Define Code ID: (see pages 14 to 21)
3
4
5
6
00 - Code 39 Full ASCII 10 - Standard 2 of 5 01 - Code 39 Standard 11 - MSI Code D3 02 - EAN-13 12 - EAN 128 03 - UPC-A 13 - Code 32 (Italian pharmacy) 04 - EAN-8 14 - Delta Code 05 - UPC-E 15 - Label Code 06 - Interleaved 2 of 5 16 - Plessey Code 07 - Codabar 17 - Code 11 (Special) 08 - Code 128 18 - China Postal Code (Toshiba Code) 09 - Code 93 * Scan two digits to choose a code (symbology), then scan characters from the Full ASCII table (pages 44 to 47)to define the code ID.
Double Verification: (see page 11) 0 - Off
1~7 - On (Verify 1~7 times)
D4 7 Scanning Mode: (see page 12)
8
0 - Trigger 1 - Flashing 3 - One Press One Scan 5 - Old Laser flash Mode
2 - Multiscan 4 - Test Mode 6 - Continuous
D5
9
MS100 Manual
33
Page 38
Scanner Port, continued
Label Type: (see page 12) 0 - Positive
1 - Positive and Negative
D6
0
Aim Function for Long Range Laser Engine: (see page 12) 0 - Disable
1
1 - Enable
D7
Data Length (Two Digits) Send: 0 - Disable
1 - Enable
D8 2
3
4
A Preamble or Postamble can be inserted before or after the scanned bar code output (a Tab, for instance). To insert a postamble, scan the “Postamble” (00) bar code, scan your selected postamble from the Function Code (page 43) or ASCII Code (pages 44 to 47) charts, and then scan the “Postamble” (00) bar code once again. To insert a preamble, follow the same procedure, but using the “PP” bar code.
Preamble
PP Postamble
OO
5
6
7
8
9
34
Exit
MS100 Manual
Page 39
Symbologies: Code 39 / I 2 of 5 / S 2 of 5 / Code 32 / Telpen / UCC/EAN128
Enter Group 6
Group Default
Code 39: 0/1 - Disable / Enable 2/3 - Full ASCII / Standard 4 - Check Digit Calculate & Send 5 - Check Digit Calculate, Not Send 6 - Check Digit Not Calculate 7/8 - Send / No Send Start/Stop 9/: - Double Labels Decoding Off / On 0 ~ 48 - Min. Length 0 / Max. Length 48 (See next page for Min./Max. Length procedure)
0
1
F1
2 Interleaved 2 of 5 (ITF): 0/1 - Disable / Enable 2/3 - Fix Length On / Off (by first three reads) 4 - Check Digit Calculate & Send 5 - Calculate Check Digit, Not Send 6 - Check Digit Not Calculate 7 - Suppress First Digit 8 - Suppress Last Digit 9 - Last Digit Not Suppressed 2 ~ 64 - Min. Length 10 / Max. Length 64 (See next page for Min./Max. Length procedure)
3
4
5
F2
Standard 2 of 5 China Postal Code (Toshiba Code):
6
0/1 - Disable/Enable 2/3 - Fix Length On / Off ( by first three reads) 4 - Check Digit Calculate & Send 5 - Check Digit Calculate, not send 6 - Check Digit not Calculate 1 ~ 48 - Min. Length 4 / Max. Length 48 (See next page for Min./Max. Length procedure)
7
F3
8
9
: MS100 Manual
35
Page 40
Code 39 / I 2 of 5 / S 2 of 5 / Code 32 / Telpen / UCC/EAN128, continued
Code 32 (Italian Pharmacy): 0/1 - Disable / Enable 2/3 - Leading Character Send / No Send 4/5 - Tailing Character Send / No Send
F4
Telepen:
0
1
0/1 - Disable / Enable 2/3 - Standard / Numeric Set
F5
UCC/EAN 128: 0/1 - Disable / Enable 2/3 - Code ID Disable / Enable Note: If EAN128 is disabled, EAN128 labels will be decoded as Code 128
F6
2 Define the EAN128 Fields Separator:
3
Scan from the ASCII Code chart (pages 44 to 47) to define a new fields separator
F7
Define a Separator for Double Labels:
4
Scan from the ASCII Code chart (pages 44 to 47) to select a new separator for double labels
Define Minimum and Maximum Length
5
6
To define minimum or maximum acceptable bar code data length, after scanning the parameter code (F1, F2, or F3) scan the “MM” or “NN” to the right, scan the number(s) to the left, and then scan the “MM” or “NN” again. Then scan “Exit” as usual.
F8
Min. Length
MM Max. Length
NN 7
8
9
36
Exit
MS100 Manual