Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 5 of 6

MS100 Bar Code Pen Reader, pages 41 to 50

Pages 41 to 50 of 59

The original document is the PDF (916 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Unitech MS100

Page 41

Symbologies: Code 128 / MSI / Code 93 / Code 11 / Codabar / Label Code

Enter Group 7

Group Default

Code 128:

0

1

2

0/1 - Disable / Enable 1-64 - Min. Length 1 / Max. Length 64 (See next page for Min./Max. Length procedure)

G1

MSI / Plessey Code: 0/1 - Disable / Enable 2/3 - Check Digit Send / No Send 4 - Check Digit Double Module 10 5 - Check Digit Module 11 plus 10 6 - Check Digit Single Module 10 1~16 - Min Length 1 / Max Length 16 (See next page for Min./Max. length procedure)

G2

3 Code 93:

4

5

6

0/1, Disable/Enable 1-48, Min Length 1 / Max Length 48 (See next page for Min./Max. Length procedure)

G3

Code 11: (Special) 0/1, Disable/Enable 2/3, One / Two Check Digit 4/5, Check Send / No Send 1-48, Min Length 1 / Max Length 48 (See next page for Min./Max. Length procedure)

G4

7

8

9

MS100 Manual

37

Page 42

Code 128 / MSI / Code 93 / Code 11 / Codabar / Label Code, continued

Codabar:

0

1

2

3

4

0/1 - Disable / Enable 2/3 - Start & Stop Send / No Send 4 - Check Digit Calculate & Send 5 - Check Digit Calculate but not Send 6 - Check Digit not Calculate 7/8 - CLSI Format On / Off 3 ~ 48 - Min Length 3 / Max Length 48 (See below for Min./Max. Length procedure)

G5

Label Code IV and V: 0/1 - Disable / Enable 2/3 - Checksum send / No send

Define Minimum and Maximum Length To define minimum or maximum acceptable bar code data length, after scanning the parameter code (G1 through G5) scan the “MM” or “NN” to the right, scan the number(s) to the left, and then scan the “MM” or “NN” again. Then scan “Exit” as usual.

G6

Min. Length

MM Max. Length

NN

5

6

7

8

9

38

Exit

MS100 Manual

Page 43

Symbologies: UPC / EAN / Delta Code

Enter Group 8

Group Default

UPC-A:

0

1

2

0/1, Disable/Enable 2/3, Leading Digit Send / No Send 4/5, Check Digit Send / No Send

H1

UPC-E: 0/1 - Disable / Enable 2/3 - Leading Digit Send / No Send 4/5 - Check Digit Send / No Send 6/7 - Zero Expansion On / Off 8/9 - Disable / Enable NSC=1

H2

EAN-13:

3

0/1 - Disable / Enable 2/3 - Leading Digit Send / No Send 4/5 - Check Digit Send / No Send 6/7 - Bookland EAN (ISBN) Enable / Disable

H3

4 EAN-8:

5

0/1 - Disable / Enable 2/3 - Leading Digit Send / No Send 4/5 - Check Digit Send / No Send

H4

Supplement Code:

6

0/1 - Two Supplement Code Off / On 2/3 - Five Supplement Code Off / On 4 - Transmit if Present 5 - Must be Present. 6/7 - Insert Space Separator / Not Insert

H5

7 Delta Distance Code:

8

9

MS100 Manual

0/1 - Disable / Enable 2/3 - Check Digit Calculate / Not Calculate 4/5 - Check Digit Send / No Send

H6

Exit

39

Page 44

Data Editing: Data Editing allows you to manipulate the bar code data output into a format that you require by scanning in the bar codes on page 42 in addition to Function Codes and ASCII Codes on pages 43 to 47. After scanning the “Enter Group 9” bar code, all the subsequent bar code input (except character string units) beginning with “IN_ID” must be separated by scanning comma bar codes, until you scan the final “Enter” followed by the “Exit” bar code. The “Enter Group 9” and the “Enter” barcodes are not followed by commas. Parameters are grouped into Qualifiers and Modifiers. Qualifiers specify the conditions that must be met in order for data editing to occur, be it minimum or maximum data length, specific symbologies, or specific character strings present. Modifiers modify the data output according to pre-set rules by either removing specified parts of the data or adding user-defined data. When programming the keyboard/scanner, qualifiers must precede modifiers. Each programming parameter is input according to the following patterns: Qualifiers: Input ID - Specific bar code symbologies can be selected for special treatment. The programming bar codes must be entered in the following sequence: IN_ID,ID1,ID2,...,IDX, - where “IN_ID” announces that the next bar code inputs refer to the various bar code symbologies according to their “Code Type” on page 48. For example, if UPC-A and Code 32 bar codes are to to be singled out for data editing, the bar code scanning sequence should be “IN_ID,3,13,”. Length - Bar codes of specific length can be selected. The programming bar codes must be entered in the following sequence: LEN,MIN,MAX, - where “LEN” announces that the next bar code inputs refer to the minimum and maximum length bar codes allowable. For example, if we only want data editing to apply to bar codes between 6 and 12 characters long, then the bar code scanning sequence should be “LEN,6,12,”. Match - Bar codes with specific character strings can be selected. The programming bar codes must be entered in the following sequence: MATCH,P1,”S1”,P2,”S2”,...,PX,”SX”, - where “MATCH” announces that the next bar code inputs will define where in the data a specific string will be located, and what characters the string consists of, surrounded by quotation marks. For example, if the bar code to be selected requires the string “efgh” beginning at the 3rd position, the bar code scanning sequence should be “MATCH,3,”efgh”,”. If we’re looking for “efgh” anywhere within the bar code, the sequence should be “MATCH,*,”efgh”,”, with the “*” character signifying that it could be anywhere in the string.

40

MS100 Manual

Page 45

Data Editing, continued Modifiers: Original Data - Part or all of the original data string can be selected. The programming bar codes must be entered in the following sequence: O-STR,P,N, - where “O-STR” announces that the next bar code inputs refer to where the output should begin and how many characters should be output. For example, if 7 characters are to be output beginning with the 4th character, the bar code scanning sequence should be “O-STR,4,7,”. If we want all the characters after the 4th character output, the sequence should be “OSTR,4,#,”, with the “#” character signifying that the entire string should be output. Should you decide that the last two characters should not be output, the sequence would be “O-STR,4,#-2,”, with “#-2” specifying all remaining minus 2. Additional Data - User-specified data can be added by simply surrounding it with quotation marks. For instance, if you want to follow the original data with the characters “123”, then simply add ”123”, after the O-STR parameter. If the additional data is to be added before the original data, then it needs to precede the O-STR parameter. Additional data can be scanned in from the Function Code or ASCII Code pages (pages 43 through 47). Special Characters

, Comma - Used as a separator between formula parameters, beginning with the IN_ID parameter and ending with the Enter parameter.

“ Quotation Mark - Used to begin and end a character string. A character string bounded by quotation marks is treated as a single unit, and would be written as “abcd”.

* Asterisk - Wild character used to specify any digit or any position. # Hash Sign - Wild character used to specify any letter or last position. Finally, end the programming sequence with the “Enter” bar code. Do not follow it with a comma. If you need to add another formula, do so now by scanning the “IN_ID” bar code directly, followed by the rest of the second formula’s parameters. Lastly, scan the “Exit” bar code. Thus, if we want to output just the first five characters only from UPC-A input and follow it with three “0”s, the scanning sequence would be the following: Enter Group 9 IN_ID , 3 , O-STR , 1 , 5 , “ 0 0 0 “ , Enter Exit If we only want to treat UPC-A this way, but still want other symbologies to output normally, the scanning sequence would be the following: Enter Group 9 IN_ID , 3 , O-STR , 1 , 5 , “ 0 0 0 “ , Enter IN_ID , 19 , O-STR , 1 , # , Enter Exit

MS100 Manual

41

Page 46

Data Editing, continued

Enter Group 9

0

1

2

3

4

5

6

7

Group Default Code Type: 0 - Code 39 Full 1 - Code 39 Std. 2 - EAN-13 3 - UPC-A 4 - EAN-8 5 - UPC-E 6 - I 2 of 5 7 - Codabar 8 - Code 128 9 - Code 93

10 - S 2 of 5 11 - MSI Code 12 - EAN 128 13 - Code 32 14 - Delta Code 15 - Label Code 16 - Plessey Code 17 - Code 11(Special) 18 - China Postal Code 19 - All Inputs

IN_ID

LEN

MATCH

Formula Format: Input ID: IN_ID,ID1,ID2,...,IDX, Length: LEN,MIN,MAX, Match: MATCH,P1,S1,P2,S2,...,PX,SX, A-String: “abc...”, O-String: O-STR,P,N,

O-STR

ID1, ID2, etc. = number for Code ID. P1, P2, etc. = position. S1, S2, etc. = string, “abc...”. P = number or string for start position. N = number of char. or string to end position. Special Characters in this section: , - delimiter to separate parameters. “ - string specifier. * - specify any digit or any position. # - specify any letter or all input.

"

*

#

Enter 8

Backspace

9

,

+

-

42

Review

Exit

MS100 Manual

Page 47

Function Codes for PC (Code 39) (Characters in parentheses represent Code 39 bar code printing)

F1 (%VA)

F2 (%VB)

F3 (%VC)

F4 (%VD)

F5 (%VE)

F6 (%VF)

F7 (%VG)

F8 (%VH)

F9 (%VI)

F10 (%VJ)

F11 (%VK)

F12 (%VL)

Esc (/FK)

Cursor Up (/FE)

Delete (/FX)

Tab (/FI)

Cursor Down (/FF)

Left Enter (/FL)

Back Tab (/FJ)

Cursor Left (/FD)

Right Enter (/FM)

Shift Make (/FP)

Cursor Right (/FC)

Page Up (/FG)

Shift Break (/FS)

Insert (/FW)

Page Down (/FH)

Ctrl Make (/FQ)

Alt Make (/FR)

Right Ctrl (/FO)

Ctrl Break (/FT)

Alt Break (/FU)

MS100 Manual

43

Page 48

ASCII Chart (Characters in parentheses represent Code 39 bar code printing)

NUL (%U)

VT ($K)

SYN ($V)

SOH ($A)

FF ($L)

ETB ($W)

STX ($B)

CR ($M)

CAN ($X)

ETX ($C)

SO ($N)

EM ($Y)

EOT ($D)

SI ($O)

SUB ($Z)

ENQ ($E)

DLE ($P)

Escape (%A)

ACK ($F)

DC1 ($Q)

FS (%B)

BEL ($G)

DC2 ($R)

GS (%C)

BS ($H)

DC3 ($S)

RS (%D)

Tab (%I)

DC4 ($T)

US (%E)

LF ($J)

NAK ($U)

Space

44

MS100 Manual

Page 49

ASCII Chart, continued (Characters in parentheses represent Code 39 bar code printing)

! (/A)

, (/L)

7

" (/B)

-

8

# (/C)

.

9

$

/

: (/Z)

%

0

; (%F)

& (/F)

1

< (%G)

` (/G)

2

= (%H)

( (/H)

3

> (%I)

) (/I)

4

? (%J)

* (/J)

5

@ (%V)

+

6

MS100 Manual

45

Page 50

ASCII Chart, continued (Characters in parentheses represent Code 39 bar code printing)

46

A

L

W

B

M

X

C

N

Y

D

O

Z

E

P

[ (%K)

F

Q

\ (%L)

G

R

] (%M)

H

S

^ (%N)

I

T

_ (%O)

J

U

' (%W)

K

V

MS100 Manual