Page 21

Bar Code Symbologies, continued MSI / Plessey Code

• Enabled toggles the ability for the keyboard/scanner to read MSI / Plessey Code on or off. Default is “Yes”. • MSI Code ID is a user-definable identification letter for MSI • • • • •

Code, which is referred to in the “Use Code ID” function (see page 11). Default is letter “O”. Plessey Code ID is the same as MSI Code ID (above), but instead applicable to Plessey Code. Default is the letter “P”. Send Check Digit toggles whether or not to send a check digit. Default is “No Send”. Check Digit Formula defines the formula to calculate the check digit. Options are: “Double Module 10”, Module 11 Plus 10”, and “Single Module 10”. Default is “Double Module 10”. Minimum Length defines the minimal length the user will accept for a valid bar code. Default is “1”. Maximum Length defines the maximum length the user will accept for a valid bar code. Default is “16”.

Code 93

• Enabled toggles the ability for the keyboard/scanner to read Code 93 on or off. Default is “Yes”. • Code ID is a user-definable identification letter for Code 93, • • which is referred to in the “Use Code ID” function (see page 11). Default is letter “L”. Minimum Length defines the minimal length the user will accept for a valid bar code. Default is “1”. Maximum Length defines the maximum length the user will accept for a valid bar code. Default is “48”.

MS100 Manual

17

Page 22

Bar Code Symbologies, continued Codabar

• Enabled toggles the ability for the keyboard/scanner to read Codabar on or off. Default is “No”. • Code ID is a user-definable identification letter for Codabar, • • • • • which is referred to in the “Use Code ID” function (see page 11). Default is letter “N”. Send Start/Stop toggles sending or not sending start/stop sentinels. Default is “No Send”. Check Digit defines whether or not a check digit (to insure data accuracy) is calculated, and if so, whether it should be sent or not. Default is “Not Calculate”. CLSI Format deletes the start and stop sentinels and outputs the data with spaces inserted after the 1st, 5th, and 10th characters. Default is “No”. Minimum Length defines the minimum length the user will accept for a valid bar code. Default is “3”. Maximum Length defines the maximum length the user will accept for a valid bar code. Default is “48”.

UPC-A

• Enabled toggles the ability for the keyboard/scanner to read UPC-A on or off. Default is “Yes”. • Code ID is a user-definable identification letter for UPC-A, which • •

18 is referred to in the “Use Code ID” function (see page 11). Default is letter “A”. Send Leading Digit toggles sending or not sending a leading (“start bar code”) digit. Default is “Send”. Send Check Digit toggles whether or not to send a check digit. Default is “Send”.

MS100 Manual

Page 23

Bar Code Symbologies, continued UPC-E

• Enabled toggles the ability for the keyboard/scanner to read UPC-E on or off. Default is “Yes”. • Code ID is a user-definable identification letter for UPC-E, which • • • • is referred to in the “Use Code ID” function (see page 11). Default is letter “E”. Send Leading Digit toggles sending or not sending a leading (“start bar code”) digit. Default is “Send”. Send Check Digit toggles whether or not to send a check digit. Default is “No Send”. Zero Expansion adds 0s to the bar code output to change the output format to UPC-A. Default is “No”. Enable NSC=1 allows the output of a UPC-E bar code with a first digit of “1”. Default is “No”.

EAN-13

• Enabled toggles the ability for the keyboard/scanner to read EAN-13 on or off. Default is “Yes”. • Code ID is a user-definable identification letter for EAN-13, which • • • is referred to in the “Use Code ID” function (see page 11). Default is letter “F”. Send Leading Digit toggles sending or not sending a leading (“start bar code”) digit. Default is “Send”. Send Check Digit toggles whether or not to send a check digit. Default is “Send”. Bookland EAN toggles whether or not to send the EAN-13 bar code data in Bookland EAN (ISBN) format. Default is “No”.

EAN-8

• Enabled toggles the ability for the keyboard/scanner to read EAN-8 on or off. Default is “Yes”. • Code ID is a user-definable identification letter for EAN-8, which • • is referred to in the “Use Code ID” function (see page 11). Default is letters “FF”. Send Leading Digit toggles sending or not sending a leading (“start bar code”) digit. Default is “Send”. Send Check Digit toggles whether or not to send a check digit. Default is “Send”.

MS100 Manual

19

Page 24

Bar Code Symbologies, continued Code 11

• Enabled toggles the ability for the keyboard/scanner to read Code 11 on or off. Default is “No”. • Code ID is a user-definable identification letter for Code 11, • • • • which is referred to in the “Use Code ID” function (see page 11). Default is letter “J”. Check Digit Number defines the check digit correct result to be either “1” or “2”. Default is “2”. Send Check Digit toggles whether or not to send a check digit. Default is “No Send”. Minimum Length defines the minimum length the user will accept for a valid bar code. Default is “1”. Maximum Length defines the maximum length the user will accept for a valid bar code. Default is “48”.

Delta Code

• Enabled toggles the ability for the keyboard/scanner to read Delta Code on or off. Default is “No”. • Code ID is a user-definable identification letter for Delta Code, • • which is referred to in the “Use Code ID” function (see page 11). Default is letter “D”. Calculate Check Digit toggles whether or not to calculate a check digit. Default is “Yes”. Send Check Digit toggles whether or not to send a check digit. Default is “Send”.

Supplement Code (for UPC-E, ISBN, EAN-13)

• Two Supplement Code toggles whether the two digit supplemental bar code is to be recognized. Default is “No”. • Five Supplement Code toggles whether the five digit supplemental bar code is to be recognized. Default is “No”. • Must Present toggles whether or not the supplemental bar code must be present in order to output data. Default is “Yes”. • Insert Space Separator toggles whether or not to output a space between the main and supplemental bar codes. Default is “No”.

20

MS100 Manual

Page 25

Bar Code Symbologies, continued Label Code IV and V

• Enabled toggles the ability for the keyboard/scanner to read Label Code IV and V on or off. Default is “No”. • Code ID is a user-definable identification letter for Code IV and V, • which is referred to in the “Use Code ID” function (see page 11). Default is letter “B”. Send Check Digit toggles whether or not to send a check digit. Default is “Send”.

MS100 Manual

21

Page 26

Data Editing Data Editing is a powerful function that can give you tremendous control over how data is exported from the scanner. After clicking on “Data Editing” the data editing icons become active. Click on the icon with the blue circle and white plus sign. The “Define Formula” pop-up box to the right appears, which is divided into two sections: “Qualifier” and “Modifier”.

Qualifier The Qualifier section defines the conditions that must be present for the bar code to be modified, such as what type of bar code it must be (Code 39, EAN-13, etc.), what length the bar code must be, or what characters (defined by a match string) the bar code must contain. When the conditions of the Qualifier are met, the bar code is then modified according to the rules defined in the “Modifier”, below.

Modifier The Modifier section contains three selections: “From Original”, “Add New”, and “Delete”. From Original extracts the desired data from the existing bar code. The Start Parameter defines the beginning of the string of data that is to be output. The start parameter can either be defined by position starting from the beginning (“From Position”), or a specific number of characters from the end of the string (“From Last Position”), or a specified number of characters before or after a user-defined character string (“After Matching”). The End Parameter defines the end of the string of data that is to be output. Three options are available: “Number Of Characters To Output”, “All Remaining”, and “After Matching”. The first two are self-explanatory. “After Matching” defines the end as a specified number of characters before or after a user-defined character string. 22

MS100 Manual

Page 27

Data Editing, continued Even if the original bar code data is not modified, if additional characters are to be added (see “Add New”, below) the original Start Parameter must be defined as From Position “1” and the End Parameter defined as “All Remaining”, otherwise, none of the original data will be output.

Add New adds characters (printing and nonprinting) to the data output from the scanner/ reader. These characters can be added before and/or after the actual scanned data (see “Move Up / Move Down”, below). Pre-defined characters include: <t>: Tab <r>: Carriage Return <n>: Line Feed <d>: Any Digit (data editing) <a>: Any Letter (data editing) <*>: Interblock Delay (data editing) <“>: “ (quotation marks) <dd>: character in hexadecimal notation <<>: < (less than) <>>: > (greater than) Characters must be bracketed by < > symbols. Letters and numbers should be represented in hexadecimal format (accessable in a linked menu). For instance, the lower-case letter “t” should be entered as <74> and the numeral 5 should be entered as <35>. Function codes (F keys, Cursor up, Enter, etc.) can also be inserted via hexadecimal code (accessable in a linked menu).

• • • • • • • • • •

Delete deletes existing modifier strings. Move Up / Move Down moves the modifiers up and down in relation to each other. The top modifier will be performed first and each one down the list will be performed in sequence. The original data (modified or unmodified) will be output according to its position in the modifier sequence.

MS100 Manual

23

Page 28

Data Editing, continued Arrange Formulas After the formulas have been created, they must be arranged in the optimum sequence by selecting formulas and using the “Move Formula” icons (see page 4). This sequence is usually according to their qualifier - from least likely to occur to most likely to occur. In the example pictured above, a series of formulas are designed to output all the data in a bar code that follows a series of “0”s. For instance, if the actual bar code is “000045678”, the desired output would be “45678” (the original minus all the 0s occurring at the beginning of the string). If there are six 0s (Formula 1), then the output starts at the seventh position. If there are five 0s (Formula 2), then the output starts at the sixth position, etc. If, instead, we were to place the qualifier for two 0s above (before) the qualifier for six 0s, then the formula stipulating two 0s would activate even if there were six 0s in the bar code because the qualifier would stop looking for 0s after it had found two. In this case, all qualifiers with three or more 0s would be disregarded, which would not be a desirable result.

The “Everything Else” Formula If a formula is entered into the Data Editing area, then all scanned bar codes will be evaluated according to this formula. If the scanned bar code does not satisfy the requirements of the Qualifier (see page 22), then no data is output. Practically speaking, the scanner has been set up to scan only bar codes that are defined by the Qualifier. You will not be able to scan other types of bar codes. The answer to this problem is to end the sequence of formulas with a formula that has no Qualifier and whose Modifier includes all the scanned data (starts at position 1 and outputs “all remaining”). An example of this can be seen as Formula 7 above. 24

MS100 Manual

Page 29

PROGRAMMING VIA SCANNER INPUT In addition to the Scanner Configuration Manager software, your Unitech scanner can also be configured via bar code scanner input, by scanning in the bar codes on the following pages. The concept is fairly simple: Parameters are associated together into groups. For instance, on page 35, “Beep Tone”, “Interblock Delay”, and “Intercharacter Delay” form a group called “Beeps and Delays”. In order to modify a particular parameter, first you must scan an “Enter Group X” bar code to start the procedure. For instance, to change the Beep Tone, first you must scan the “Enter Group 2” bar code. The scanner will emit a triple beep which indicates that the scanner has entered configuration mode. (The scanner will remain in configuration mode until the "Exit" bar code has been scanned.) Then you must scan the bar code of the parameter you’d like to modify. To modify the Beep Tone, scan the “A1” label. Then select a number along the left side of the page that corresponds with the modification you wish to make. To set the Beep Tone to “High”, scan the “3” label. Please note that factory default settings are printed in bold face. If you’d like to modify another parameter within the same group, scan another parameter label now. To change “Intercharacter Delay”, scan the “A3” label. Then scan the number that corresponds with your requirements. After you’re finished modifying your selected parameters in “Beeps and Delays”, scan the “Exit” bar code at the bottom of the page to end the modification session. The keyboard will emit a double beep to indicate that it is no longer in configuration mode. An easy alternative programming method is to simply scan in the bar codes in the Quick Setup labels on the next page, if appropriate.

MS100 Manual

25

Page 30

Quick Setup Bar Codes Device Type PS/2 PC AT (PS/2)

Macintosh

IBM Terminal USB

Keyboardless Serial Interface Terminal Wedge

Code 39 Wand Emulation

Inter-Character Delay

1 ms

Scanner Mode

Code ID 20 ms

Trigger

No

Terminator Flash

Yes Enter

Beep

Scan Code Field Exit

26

None

U.S.

Medium

Alt Key

MS100 Manual