Page 11

Keyboard Wedge Your Unitech keyboard contains a built in data decoder or “wedge” that translates raw bar code input into Keyboard Scan Code, with the result that bar code data exits the scanner as if you had typed the text. Seven keyboard wedge parameters are listed below:

Function Code Function Code determines how function code characters from the scanner is output. If Yes is selected, then scanned function codes will output the same as if their corresponding function keys were pressed. Scanning an F1 label will pop-up a “Help” box, F3 a “Find” pop-up box, etc. If No is selected, the scanned function codes will output special character strings defined by Unitech for non-print character output. Default is “Yes”.

• •

Caps-Lock The Caps Lock function determines how the Caps Lock key controls the case of alphabetical characters. The three options below are available: Auto Trace automatically determines the Caps Lock key status and informs the decoder accordingly. Lower Case manually coordinates the physical state of the Caps Lock key with the Caps Lock state of the decoder. For example, if the Caps Lock light is not on, then “Lower Case” should be selected. Upper Case is the same as Lower Case (above) except that it applies to the upper case state. If the Caps Lock is on, then Upper Case should be selected. Default is “Auto Trace”.

• • •

MS100 Manual

7

Page 12

Keyboard Wedge, continued Language Your Unitech scanner can output characters using eleven different language sets, including: Danish French Norwegian Swiss U.S. English German Swedish Alt Key Mode U.K. English Italian Spanish Default is “U.S.”

Wand Emulation Output Wand emulation refers to raw, undecoded bar code data - 0s and 1s. The choice here is whether to assign a 1 (high) to the dark bar and a 0 (low) to the white space - or vice-versa. Bar with High / Space with Low Bar with Low / Space with High Default is “Bar with High / Space with Low”.

Level Duration of Minimal Width This adjustment refers to the amount of time the wand scanner requires to recognize an individual bar in a bar code. The choices are 200 µs (microseconds) or 600 µs. Default is “200 µs”.

Polarity of Idle Condition The polarity of the idle condition (while it has no input) of the wand scanner can be either high or low. Default is “Low”.

Use Numeric Keypad The ASCII code for numeric input from the keypad part of the keyboard is different from that of the upper row of the keyboard proper. Some accounting programs require keypad input, and for that reason, the keyboard decoder can output scanned or read numbers as either keypad or keyboard (upper row) output. Default is “No”.

8

MS100 Manual

Page 13

RS232 Baud Rate Baud Rate (bits per second) refers to the speed of the data through the RS232 port. If the data error rate is unacceptably high, setting the baud rate lower should help. Default is “9600 Baud”.

Parity A technique used to detect data transmission errors by adding an extra bit to each character. This scheme has been supplanted in modern communication devices by “error correction”. Default (and the current universal standard) is “No Parity”.

Data Bit Number of bits per byte that are dedicated to data (minus start/stop bits). Default (and the current universal standard) is “8 Data Bits”.

Handshaking Handshaking is the mechanism that controls the speed of data flow so that a slower receiver of data is not overwhelmed by a faster sender of data. Selections are: “Ignore”, “RTS (request to send) Enabled at Power Up”, and “RTS Enabled in Communication”. Default is “Ignore”

ACK/NAK Data characters that are sent from the receiver to the sender in order to “acknowlege” or “not acknowlege” the receipt of the data without error. Rarely used these days. Default is “No”.

BCC Character Block Check Character. An error checking character added for data integrity. Default is “No”. MS100 Manual

9

Page 14

RS232, continued Time Out The ACK/NAK function (see page 9) can be given a limited (ranging from 1 second to 10 seconds) or unlimited amount of time to operate. Default is “1 Second”.

Data Direction Three options are available for data direction: “Send to Host”, “Send to Host & Terminal”, and “Send to Terminal”. Default is “Send to Host”.

Receive Terminator A user-definable Receive Terminator can be inserted at the end of bar code data. Pre-defined receive terminators include: <t>: Tab <r>: Carriage Return <n>: Line Feed <d>: Any Digit <a>: Any Letter <*>: Interblock Delay <“>: “ (quotation marks) <dd>: character in hexadecimal notation <<>: < <>>: > The above special characters must be bracketed by < > symbols as shown. Function codes (F keys, cursor up, Enter, etc.) can also be inserted via hexadecimal code (accessable in a linked menu) and must include surrounding brackets (<>). Letters and numbers should be entered directly by keyboard input without surrounding brackets (<>). Default is “None”.

• • • • • • • • • •

10

MS100 Manual

Page 15

Scanner Port Terminator, Use Code ID, Double Verification, Scanning Mode, Label Type, Aim Function for Long-Range Engine, Aim Time for Long-Range Engine, Preamble, and Postamble are the parameters for Scanner Port configuration.

Terminator The Terminator is a command that follows the input of bar code data. Four different terminators can be selected here: “Enter”, “Return (on numeric keypad)”, “Field Exit or Right Control”, or “None”. Alternative terminators (such as Tab) can be be configured via the Postamble function (see page 13). Default is “Enter” UPC-A A UPC-E E EAN-13 F Use Code ID EAN-8 FF I 2 of 5 I The Code ID function can be used to S 2 of 5 H identify the type of bar code that is Code 39 M being scanned by inserting an identifyCodabar N ing letter (refer to chart at right) at the Code 93 L beginning of the bar code output. Code 128 K For example, if the Code ID function is UCC/EAN128 ]C1 on, and a bar code string of “54321” MSI O was output as “M54321”, the bar code Code 32 T would thus be identified as type Code Plessey Code P 39. Label Code IV, V B Default is “No”. Toshiba Code C Code 11 / Telpen J Delta Code D Double Verification Double Verification enables the scanner to verify the accuracy of the output by outputting only after a specified number (from 0 to 7) of identical results. For instance, if 3 is selected, the scanner will not output the bar code data until it’s obtained 4 identical scan results. Because the scanner normally scans at a rate of 33 scans per second (unless it’s a wand), this process should take less than a fraction of a second, even for higher values. Default is “0-Off” MS100 Manual

11

Page 16

Scanner Port, continued Scanning Mode Actual bar code scanning can occur in six different ways: Trigger scan causes the scanner light to remain on as long as the trigger is depressed, whether the bar code is recognized or not. Flashing causes the scanner to flash continuously after the trigger is pressed until it detects a bar code and outputs the data. The scanner light will remain on in anticipation of another bar code for approximately 12 seconds, after which it will begin flashing again. A second trigger press stops the scanning. Multiscan allows multiple scans while holding down the trigger. One Press One Scan causes the scanner light to remain on after the trigger is briefly depressed until a bar code is detected and output. Test is similar to the Flash setting except that the scanner outputs bar code data in a rapid-fire manner as long as a bar code is presented to the scanner. Old Laser Flash causes the scanner to flash continuously after the trigger is pressed and will scan each bar code only once per presentation. A second trigger press stops the scanning. Continuous causes the scanner light to remain on and scan bar codes as they are presented. Bar codes can be “double scanned” only after a short interval. Default is “Trigger”

• • • • • • •

Label Type Toggle between reading only Positive and both Positive and Negative bar codes. Reading both positive and negative bar codes can be useful in the graphics industry when negative images must be proofed. Default is “Positive”.

Aim Function for Long Range Engine The Aim Function causes a laser scanner to output a “pin-point” aiming aid for a specified period of time (see below) to enable the user to more easily scan distant bar code labels. This function can be toggled on or off. Default is “No”. 12

MS100 Manual

Page 17

Scanner Port, continued Aiming Time for Long Range Engine The Aiming Time function specifies the duration of the Aim Function (see previous page). Length of duration can be specified from 500ms to 2 seconds, in half-second increments. Default is “1 second”.

Preamble Insert a string of characters prior to the actual scanned data. Pre-defined characters include: <t>: Tab <r>: Carriage Return <n>: Line Feed <d>: Any Digit <a>: Any Letter <*>: Interblock Delay <“>: “ (quotation marks) <dd>: character in hexadecimal notation <<>: < <>>: > The above special characters must be bracketed by < > symbols as shown. Function codes (F keys, cursor up, Enter, etc.) can also be inserted via hexadecimal code (accessable in a linked menu) and must include surrounding brackets (<>). Letters and numbers should be entered directly by keyboard input without surrounding brackets (<>). Default is “None”

• • • • • • • • • •

Postamble Identical to Preamble (above), but characters are inserted after scanned data. A common postamble would be to insert a “Tab” in lieu of an “Enter” terminator (see page 11). Default is “None”

MS100 Manual

13

Page 18

Bar Code Symbologies Modify the output characteristics of 16 of the most popular bar code symbologies in current use. Following are the bar code symbologies and their modifiable parameters.

Code 39

• Enabled toggles the ability for the keyboard/scanner to read Code 39 on or off. Default is “Yes”. • Code ID (Standard) is a user-definable identification letter for • • • • • •

14

Standard Code 39, which is referred to in the “Use Code ID” function (see page 11). Default is letter “M”. Code ID (Full ASCII) is the same as Code ID (Standard), above, except that the symbology is Full ASCII Code 39. Default letter is also the letter “M”. Type toggles Code 39 between Standard and Full ASCII. Default is “Full ASCII”. Check Digit defines whether or not a check digit (to insure data accuracy) is calculated, and if so, whether it should be sent or not. Default is “Not Calculate”. Send Start/Stop toggles sending or not sending start/stop sentinels (* in the case of Code 39). Default is “No Send”. Minimum Length defines the minimum length the user will accept for a valid bar code. Default is “0”. Maximum Length defines the maximum length the user will accept for a valid bar code. Default is “48”.

MS100 Manual

Page 19

Bar Code Symbologies, continued Interleaved 2 of 5

• Enabled toggles the ability for the keyboard/scanner to read I 2 of 5 on or off. Default is “Yes”. • Code ID is a user-definable identification letter for I 2 of 5, which • • • • • is referred to in the “Use Code ID” function (see page 11). Default is letter “I”. Fix Length (by first 3 reads) fixes the length of acceptable subsequent bar code reads from the first three bar codes read. Useful as a data verification if all bar codes are of a consistent length. Default is “No”. Check Digit defines whether or not a check digit (to insure data accuracy) is calculated, and if so, whether it should be sent or not. Default is “Not Calculate”. Suppress Digit suppresses the output of the first or last bar code digit. Default is “Not Suppressed”. Minimum Length defines the minimum length the user will accept for a valid bar code. Default is “10”. Maximum Length defines the maximum length the user will accept for a valid bar code. Default is “64”.

Standard 2 of 5 / Toshiba Code (China Postal Code)

• Enabled toggles the ability for the keyboard/scanner to read S 2 of 5 / Toshiba Code on or off. Default is “No”. • S25 Code ID is a user-definable identification letter for S 2 of 5, • • • • • which is referred to in the “Use Code ID” function (see page 11). Default is letter “H”. Toshiba Code ID is the same as S25 Code ID (above), but instead applicable to Toshiba Code. Default is letter “C”. Fix Length (by first 3 reads) fixes the length of acceptable subsequent bar code reads from the first three bar codes read. Useful as a data verification if all bar codes are of a consistent length. Default is “No”. Check Digit defines whether or not a check digit (to insure data accuracy) is calculated, and if so, whether it should be sent or not. Default is “Not Calculate”. Minimum Length defines the minimum length the user will accept for a valid bar code. Default is “4”. Maximum Length defines the maximum length the user will accept for a valid bar code. Default is “48”.

MS100 Manual

15

Page 20

Bar Code Symbologies, continued Code 32

• Enabled toggles the ability for the keyboard/scanner to read Code 32 on or off. Default is “No”. • Code ID is a user-definable identification letter for Code 32, • • which is referred to in the “Use Code ID” function (see page 11). Default is letter “T”. Send Leading Character toggles sending or not sending a leading (“start bar code”) character. Default is “Send”. Send Tailing Character toggles sending or not sending a tailing (“stop bar code”) character. Default is “Send”.

EAN 128

• Enabled toggles the ability for the keyboard/scanner to read EAN 128 on or off. Default is “No”. • Code ID is a user-definable identification letter for EAN 128, • • which is referred to in the “Use Code ID” function (see page 11). Default is “None”. Enable Code ID determines whether or not to assign a Code ID. Default is “No”. Field Separator is a user-definable character to insert between fields. Default is “None”.

Code 128

• Enabled toggles the ability for the keyboard/scanner to read Code 128 on or off. Default is “Yes”. • Code ID is a user-definable identification letter for Code 128, • •

16 which is referred to in the “Use Code ID” function (see page 11). Default is letter “K”. Minimum Length defines the minimum length the user will accept for a valid bar code. Default is “1”. Maximum Length defines the maximum length the user will accept for a valid bar code. Default is “64”.