Page 41 read from a scan by OCR; it may hold reading errors

Intercharacter Delay

MN Rolling buffer

(If Rolling Buffer Active) Intermessage Delay

INN I INA IN IN MI I

*No delay 5 ms

10 ms

15 ms

20 ms

30 ms

50 ms

Active

*Not Active

No delay *100 ms 500 ms

1 sec

2 sec

5 sec

© United Barcode Industries

Page 4-16

Page 42 read from a scan by OCR; it may hold reading errors

Notes to Family C

Preamble and Postamble

Character strings can be transmitted by the MagScan before each message as a preamble, or after each message as a postamble. Preambles and postambles can be assigned to individual ports; and control codes can be used. For example, messages from the magnetic stripe reader could be preceded by an M and followed by a tab, while messages from the bar code scanner could be preceded by a B and followed by an enter. A total of 33 characters may be entered among all active preambles and/or postambles.

Intercharacter Delay

In some terminals or RS-232 systems, the maximum rate at which data can be transmitted by the MagScan is affected by the response of the system. By the insertion of an intercharacter delay, the MagScan can avoid dropping characters, if it is transmitting decoded data too rapidly.

Rolling Buffer

When codes are scanned faster than the host system can accept data, messages can be spooled in the MagScan’s "rolling buffer" on a first in first out basis.

The rolling buffer may be deactivated if the operator is required to verify the transmission of each record to the host before the next record is scanned.

Intermessage Delay

The intermessage delay is used to slow the rate at which successive records are transmitted to the host.

Page 4-17 © United Barcode Industries

Page 43 read from a scan by OCR; it may hold reading errors

Family D -

BAR CODE FORMATS

Select Family D

I End Selection | IN

Read the bar code(s) corresponding to the code formats to be activated. Only those codes or groups of codes required should be activated.

Scan End Selection WIM] Code 89 when all desired code formats are specified. HANNA Interleaved 2 of 5

MIMI Standard 2 of s IMI Codabar/Ames

IMI, UPC/EAN

IMM Code 128

IMIMIN st / Plessey

IMMIIM Code 14 7 Code 93

WAM *Code 39 + Codabar + UPC/EAN + Interleaved 2 of 5

© United Barcode Industries Page 4-18

Page 44 read from a scan by OCR; it may hold reading errors

Family E

CODE 39 PARAMETERS

Select Family E

NA

End Selection

UNCUT

Character Set

HNC (AN MN) “Fe! ASU {IMNIT Wl II] Standard 43 Characters Start/Stop ON HHUA | Transmitted (MUM WI! *Not Transmitted $/$ Start/Stop A

MINIM! Active - $/$ only MIT NII Active-s/g + */*

MIMI! *Not Active

Page 4-19 © United Barcode Industries

Page 45 read from a scan by OCR; it may hold reading errors

Check Digit

NEL

HIBC Format

Multiread

UA

NA WU

NA NN A OUT WN) 0

Mod 43 calculated and transmitted

Mod 43 calculated but not transmitted

CIP transmitted

CIP not transmitted Italian transmitted Italian not transmitted

*Not used

Active

*Notactive

Activated by leading space

Activated by user selected character-- scan a character from the full ASCII test chart in Appendix B-1

*Not Active

© United Barcode Industries

Page 4-20

Page 46 read from a scan by OCR; it may hold reading errors

Full ASCII Control Codes

[MINIMI §= Active in separate label of two char- acters, and embedded in a code

[MINI © *Active in separate label, and embedded in a code if preceded by a hyphen (-)

(NTI © Active in separate label of two char- acters only

(MINIM Not active

Page 4-21 © United Barcode Industries

Page 47 read from a scan by OCR; it may hold reading errors

Notes to Family E

Modulo 43 Check Digit

The modulo 43 check digit is a character added to the end of the Code 39 bar code label which allows an extra validation of the data.

It is calculated as follows:

1. Replace each of the characters by the corresponding value in the table below, noting that the start and stop are not used in calculating the check digit.

2. Sum all the values. 3. Divide this sum by 43 and note the remainder.

4. The check digit is the character in the Standard ASCIl table of 43 characters corresponding to the remainder in step 3.

Take as an example the following label *56789ADF $cd*

The values to be summed are: S$=5+64+74+8+9410+134+15+39=112 R = 112/43 = 2with a remainder of 26

26 corresponds to Q cd = "Q"

Therefore the label with the check digit is *56789ADF$Q*

The reader can be set to transmit or not transmit the Mod 43 check digit.

© United Barcode Industries Page 4-22

Page 48 read from a scan by OCR; it may hold reading errors

Figure 4.1

Code 39 Character Values for Calculating Modulo 43 Check Digit

Character Value

0-9 0-9

A-Z 10 - 35

-- 36 37 space 38

$ 39

/ 40

+ At

% 42

Itir The multiread function allows Code 39 labels beginning with a predetermined character to be put into the MagScan’s memory. One or more of these labels is retained in memory until a controllable is read, which may be a transmit label (**), or until a label not beginning with the multiread character is read.

This function allows a message to be composed "off-line" from the terminal or host, by reading a series of multiread labels.

The multiread character can be either a space, which is widely used, or any other Code 39 character defined by the user.

Page 4-23 © United Barcode Industries

Page 49 read from a scan by OCR; it may hold reading errors

HIBC Format

The Health Industry Bar code Council format is used by the American pharmaceutical industry and many hospitals and blood banks. It makes use of the modulo 43 check digit.

Full ASCII Control Codes

Activates or deactivates the bar code control functions from the command menus in Appendix B-1 and C-1. This allows the emulation of control keys such as special function keys, tab or back space, by reading bar code labels consisting of specially defined dual character combinations. For example the characters .B can represent an Enter. The translations for the control codes in Appendix B-1 and C- 1 are provided in Appendices B-2 and C-2 respectively.

These control codes can be activated either when in a separate label or when embedded in a label, usually as the last two characters.

© United Barcode Industries Page 4-24

Page 50 read from a scan by OCR; it may hold reading errors

Family F INTERLEAVED 2 OF 5 PARAMETERS

Select Family F

(AANA A End Selection URN Number of Characters (AA (NMI “Even Number {MT lll HH Odd Number -- select suppressed character, below Odd Number Suppressed Character (AA A

First character UA A suppressed

[MMT] | *Last character suppressed

Page 4-25 © United Barcode Industries